Why we use the term non-active power, and how it can be measured under non-ideal power supply conditions

被引:0
|
作者
Gaunt, C. T. [1 ]
Malengret, M. [1 ]
机构
[1] Univ Cape Town, Dept Elect Engn, ZA-7700 Rondebosch, South Africa
关键词
CURRENTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper identifies the difference between the terms reactive power and non-active power and describes them in terms of a general power theory that has been developed for m-wire systems in the instantaneous and average power domains. The differences between conventional measurements and the new approach are demonstrated using laboratory-scale three-phase transformers under conditions similar to those experienced on large power systems carrying geomagnetically induced currents, with harmonic distortion, unbalance and dc components. The implications affect all multi-wire systems under non-ideal conditions, including distorting loads and smart grid integration.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Distributed Economic Dispatch of Virtual Power Plant under a Non-Ideal Communication Network
    Cao, Chi
    Xie, Jun
    Yue, Dong
    Huang, Chongxin
    Wang, Jixiang
    Xu, Shuyang
    Chen, Xingying
    ENERGIES, 2017, 10 (02):
  • [32] Performance analysis of CDMA system with integrated services under non-ideal power control
    Guan, Hao
    Li, Chengshu
    Tiedao Xuebao/Journal of the China Railway Society, 2000, 22 (06): : 76 - 79
  • [33] Harmonic and reactive power compensation with shunt active power filter under non-ideal mains voltage (vol 14, pg 363, 2005)
    Kale, M
    Özdemir, E
    ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (6-7) : 600 - 600
  • [34] Neural Network Based Shunt Active Filter for Harmonic and Reactive Power Compensation under Non-ideal Mains Voltage
    Gupta, Nitin
    Singh, S. P.
    Dubey, S. P.
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 1, 2010, : 395 - 400
  • [35] Synchronous Reference Frame Based Control Technique for Shunt Hybrid Active Power Filter under Non-ideal Voltage
    Dey, Papan
    Mekhilef, Saad
    2014 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2014, : 481 - 486
  • [36] Experimental characterisation of active and non-active harmonic power flow of AC rolling stock and interaction with the supply network
    Mariscotti, Andrea
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2021, 11 (02) : 109 - 120
  • [37] Design and control of a three-phase active rectifier under non-ideal operating conditions
    Liserre, M
    Dell'Aquila, A
    Blaabjerg, F
    CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 1181 - 1188
  • [38] A Novel Harmonic Identification Algorithm for the Active Power Filters in Non-Ideal Voltage Source Systems
    Santiprapan, Phonsit
    Areerak, Kongpol
    Areerak, Kongpan
    JOURNAL OF POWER ELECTRONICS, 2017, 17 (06) : 1637 - 1649
  • [39] Active power reference tracking in electricity distribution grids over non-ideal communication networks
    Kristensen, Thomas le Fevre
    Olsen, Rasmus Lovenstein
    Pedersen, Rasmus
    Iov, Florin
    Schwefel, Hans-Peter
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 102 : 122 - 130
  • [40] An Advanced Shunt Active Power Filter (SAPF) for Non-ideal Grid Using Predictive DPC
    Rath, Abinash
    Srungavarapu, Gopalakrishna
    IETE TECHNICAL REVIEW, 2023, 40 (04) : 521 - 534