Synchronous Reference Frame Based Control Technique for Shunt Hybrid Active Power Filter under Non-ideal Voltage

被引:0
|
作者
Dey, Papan [1 ]
Mekhilef, Saad [1 ]
机构
[1] Univ Malaya, Power Elect & Renewable Energy Res Lab PEARL, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
来源
2014 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA) | 2014年
关键词
Active power filter (APF); phase locked loop (PLL); harmonics; power quality; synchronous reference frame (SRF);
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
A hybrid compensator which is a combination of a three phase four wire shunt active power filter and a parallel passive filter has been presented in this paper. The dominant lower order harmonics as well as reactive power can be compensated by passive elements whereas the active part mitigates remaining distortions and improves the power quality. Modified phase lock loop based synchronous reference frame control strategy is adopted here for active filtering system. The proposed three phase hybrid line conditioning system can be quite effective for recompensing harmonics, reactive power & neutral current under unbalanced grid conditions. The simulated results obtained by MATLAB/SIMULINK power system block set are examined in detail for the validity of suggested approach. A laboratory prototype has been built on dSPACE1104 platform to verify the feasibility of the suggested SHAPF controller.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [1] Control of the Shunt Active Power Filter under Non-Ideal Grid Voltage and Unbalanced Load Conditions
    Biricik, Samet
    Redif, Soydan
    Ozerdem, Ozgur Cemal
    Basu, Malabika
    2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [2] Harmonic and reactive power compensation with shunt active power filter under non-ideal mains voltage
    Kale, M
    Özdemir, E
    ELECTRIC POWER SYSTEMS RESEARCH, 2005, 74 (03) : 363 - 370
  • [3] Investigating the ability of shunt hybrid power filter based on SRF method under non-ideal supply voltage
    Omran, Mohamed A.
    Mohd, Izzeldin I.
    Almelian, Mohamad M.
    Sheikh, Usman Ullah
    Bofares, Mustafa E. A. A.
    INTERNATIONAL CONFERENCE ON INNOVATIVE TECHNOLOGY, ENGINEERING AND SCIENCES 2018 (ICITES 2018), 2018, 342
  • [4] PERFORMANCE INVESTIGATION OF SHUNT HYBRID ACTIVE POWER FILTER WITH A SYNCHRONOUS REFERENCE FRAME BASED CONTROLLER
    Tan, Adnan
    Koroglu, Tahsin
    Demirdelen, Tugce
    Inci, Mustafa
    Cuma, M. Ugras
    Bayindir, K. Cagatay
    Tumay, Mehmet
    2015 IEEE 6TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2015, : 391 - 398
  • [5] A novel control method for active power filter under non-ideal mains voltage
    Özdemir, E
    Kale, M
    Özdemir, S
    CCA 2003: PROCEEDINGS OF 2003 IEEE CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 2003, : 931 - 936
  • [6] Current detection control of active power filter under non-ideal voltage source
    Electrical Engineering Institute, Southwest Jiaotong University, Chengdu 610031, China
    Xinan Jiaotong Daxue Xuebao, 2006, 1 (31-36):
  • [7] Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame
    Al-Othman, A. K.
    AlSharidah, M. E.
    Ahmed, Nabil A.
    Alajmi, Bader. N.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2016, 11 (02) : 405 - 415
  • [8] Modeling and nonlinear control of shunt active power filter in the synchronous reference frame
    Mendalek, N
    Al-Haddad, K
    NINTH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER PROCEEDINGS, VOLS I - III, 2000, : 30 - 35
  • [9] P-Q theory based Shunt Active Power Filter for power quality under Ideal and Non-ideal Grid voltage Conditions
    Raj, Geethu S.
    Rathi, K.
    PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON POWER, INSTRUMENTATION, CONTROL AND COMPUTING (PICC), 2015,
  • [10] Optimisation-based strategy for shunt active power filter control under non-ideal supply voltages
    Chang, GW
    Yeh, CM
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02): : 182 - 190