Why we use the term non-active power, and how it can be measured under non-ideal power supply conditions

被引:0
|
作者
Gaunt, C. T. [1 ]
Malengret, M. [1 ]
机构
[1] Univ Cape Town, Dept Elect Engn, ZA-7700 Rondebosch, South Africa
关键词
CURRENTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper identifies the difference between the terms reactive power and non-active power and describes them in terms of a general power theory that has been developed for m-wire systems in the instantaneous and average power domains. The differences between conventional measurements and the new approach are demonstrated using laboratory-scale three-phase transformers under conditions similar to those experienced on large power systems carrying geomagnetically induced currents, with harmonic distortion, unbalance and dc components. The implications affect all multi-wire systems under non-ideal conditions, including distorting loads and smart grid integration.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] ACTIVE POWER FILTERING UNDER NON-IDEAL VOLTAGE CONDITIONS USING THE CONSERVATIVE POWER THEORY
    Haugan, Thomas S.
    Tedeschi, Elisabetta
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [2] Operation of an active power filter with line voltage SVM under non-ideal conditions
    Zhang, Huibin
    Massoud, A. M.
    Finney, S. J.
    Williams, B. W.
    Fletcher, J. E.
    2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 149 - +
  • [3] Optimal non-active power compensation under non-sinusoidal conditions
    Tomislav B. Šekara
    Jovan Č. Mikulović
    Electrical Engineering, 2006, 88 : 423 - 429
  • [4] Optimal non-active power compensation under non-sinusoidal conditions
    Sekara, Tomislav B.
    Mikulovic, Jovan C.
    ELECTRICAL ENGINEERING, 2006, 88 (05) : 423 - 429
  • [5] Advanced static VAr compensator performance under non-ideal electric power supply conditions
    Gonçalves, WKA
    de Oliveira, JC
    Franco, VLS
    NINTH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER PROCEEDINGS, VOLS I - III, 2000, : 554 - 559
  • [6] An Improved One Cycle Control for Active Power Filters under Non-Ideal Voltage Conditions
    Wang, Lei
    Ren, Chunguang
    Yang, Yu
    Han, Xiaoqing
    Wang, Peng
    JOURNAL OF POWER ELECTRONICS, 2016, 16 (06) : 2350 - 2358
  • [7] Power Quality Enhancement Using a New Hybrid Active Power Filter Under Non-Ideal Source and Load Conditions
    Hosseini, Seyed Hossein
    Nouri, Tohid
    Sabahi, Mehran
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 941 - 946
  • [8] Power Quality Enhancement by Power Electronic Generation Interface under Non-Ideal Voltage Conditions
    Jelani, Nadeem
    Molinas, Marta
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 2161 - 2166
  • [9] Operation of a wye connected three-level active power filter under non-ideal conditions
    Zhang, H. B.
    Massoud, A. M.
    Finney, S. J.
    Williams, B. W.
    Lim, T. C.
    Hotait, H.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 299 - +
  • [10] Control of the Shunt Active Power Filter under Non-Ideal Grid Voltage and Unbalanced Load Conditions
    Biricik, Samet
    Redif, Soydan
    Ozerdem, Ozgur Cemal
    Basu, Malabika
    2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,