Power Quality Enhancement by Power Electronic Generation Interface under Non-Ideal Voltage Conditions

被引:0
|
作者
Jelani, Nadeem [1 ]
Molinas, Marta [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7034 Trondheim, Norway
关键词
Current's physical components; distributed generation; IRP p-q theory; non-linear load; power electronics; pulse width modulation; reactive power; shunt active filter; voltage source converters; FILTERS; SHUNT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Distributed generation (DG) interfaced to the grid through power electronic (PE) interface can be used to provide reactive power for voltage stability in a power system they are part of. Furthermore, they can be used to minimize the harmonic issues caused by the PE non-linear loads present at the distribution level. This article investigates the possibility of using a generation side PE interface for shunt active filtering in addition to supply the active power demand to the consumers under non-ideal source voltage conditions. Reference signal generation techniques for shunt compensator are based on instantaneous reactive power (IRP) p-q theory and the theory of current's physical components (CPC), in rotating synchronous reference frame (SRF). Converter control is based on vector control method. IRP p-q theory based reference signal generation technique uses filters to extract the desired current components. CPC utilizes frequency domain methods to compute the current references Simulation results show that the generation interface performs shunt active filtering very efficiently. However, it is observed that the source current distortion is further increased due to the reduction of fundamental current component in the source current when generation interface supplies the active power to the power network.
引用
收藏
页码:2161 / 2166
页数:6
相关论文
共 50 条
  • [1] ACTIVE POWER FILTERING UNDER NON-IDEAL VOLTAGE CONDITIONS USING THE CONSERVATIVE POWER THEORY
    Haugan, Thomas S.
    Tedeschi, Elisabetta
    [J]. 2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [2] Power Quality Enhancement Using a New Hybrid Active Power Filter Under Non-Ideal Source and Load Conditions
    Hosseini, Seyed Hossein
    Nouri, Tohid
    Sabahi, Mehran
    [J]. 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 941 - 946
  • [3] P-Q theory based Shunt Active Power Filter for power quality under Ideal and Non-ideal Grid voltage Conditions
    Raj, Geethu S.
    Rathi, K.
    [J]. PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON POWER, INSTRUMENTATION, CONTROL AND COMPUTING (PICC), 2015,
  • [4] Operation of an active power filter with line voltage SVM under non-ideal conditions
    Zhang, Huibin
    Massoud, A. M.
    Finney, S. J.
    Williams, B. W.
    Fletcher, J. E.
    [J]. 2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 149 - +
  • [5] Power quality enhancement with PAC-SRF based Single Phase UPQC under non-ideal source voltage
    Panda, Anup Kumar
    Patnaik, Nishant
    Patel, Ranjeeta
    [J]. 2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,
  • [6] An Improved One Cycle Control for Active Power Filters under Non-Ideal Voltage Conditions
    Wang, Lei
    Ren, Chunguang
    Yang, Yu
    Han, Xiaoqing
    Wang, Peng
    [J]. JOURNAL OF POWER ELECTRONICS, 2016, 16 (06) : 2350 - 2358
  • [7] Control of phase locked loop for wind power generation under non-ideal grid conditions
    Liu, Changjin
    Xu, Jun
    Chen, Min
    Xu, Dehong
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2012, 27 (04): : 240 - 247
  • [8] A Novel Control Method for Unified Power Quality Conditioner (UPQC) Under Non-Ideal Mains Voltage and Unbalanced Load Conditions
    Kesler, Metin
    Ozdemir, Engin
    [J]. 2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 374 - 379
  • [9] Control of the Shunt Active Power Filter under Non-Ideal Grid Voltage and Unbalanced Load Conditions
    Biricik, Samet
    Redif, Soydan
    Ozerdem, Ozgur Cemal
    Basu, Malabika
    [J]. 2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [10] Harmonic and reactive power compensation with shunt active power filter under non-ideal mains voltage
    Kale, M
    Özdemir, E
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2005, 74 (03) : 363 - 370