The use of sodium hydroxoaluminate in water conditioning for cooling systems in industry and power engineering

被引:0
|
作者
Makarenko, I. N. [1 ]
Shablii, T. A. [1 ]
Krysenko, T. V. [1 ]
机构
[1] Natl Tech Univ, Kyivskyi Politekhnichnyi Inst, Kiev, Ukraine
关键词
Water Softening; Aluminum Sulfate; Water Conditioning; Copper Removal; Water Treatment Station;
D O I
10.3103/S1063455X09050063
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Processes of softening water with a high level of hardness with alkali, soda, and lime using phosphate and sodium hydroxoaluminate have been investigated. It has been shown that the water softening degree increases with an increase of the medium pH and the dose of phosphate or aluminate. It have been found that the use of sodium aluminate makes it possible to reduce water hardness to 0.2-0.3 mgeq/dm(3) irrespective of the amount of natural water and is the most effective compared with the use of sodium phosphate. The article has determined the impact of sodium aluminate on the water purification degree of copper ions and showed that at the corresponding doses sodium aluminate secures complete removal of copper ions from the water.
引用
收藏
页码:310 / 315
页数:6
相关论文
共 50 条
  • [21] Use of Shitalakhya River Water as Makeup Water in Power Plant Cooling System
    Choudhury, Mahbuboor R.
    Siddik, Md. Abu Z.
    Salam, Md. Zilley E. I.
    KSCE JOURNAL OF CIVIL ENGINEERING, 2016, 20 (02) : 571 - 580
  • [22] Use of Shitalakhya River Water as makeup water in power plant cooling system
    Mahbuboor R. Choudhury
    Md. Abu Z. Siddik
    Md. Zilley E. I. Salam
    KSCE Journal of Civil Engineering, 2016, 20 : 571 - 580
  • [23] Performance evaluation of the use of accumulating systems in the power industry
    Volkonskii V.A.
    Kuzovkin A.I.
    Chakhovskii V.M.
    Glukhova M.V.
    Yemets A.I.
    Studies on Russian Economic Development, 2010, 21 (2) : 132 - 145
  • [24] Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China
    Lin, H.
    Xu, B.
    Chen, Y.
    Wang, W.
    JOURNAL OF APPLIED MICROBIOLOGY, 2009, 106 (02) : 606 - 612
  • [25] Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait
    Qadreyah Al-Matawah
    Sameer Al-Zenki
    Ahmad Al-Azmi
    Tahani Al-Waalan
    Fadila Al-Salameen
    Ahmad Ben Hejji
    Environmental Science and Pollution Research, 2015, 22 : 10235 - 10241
  • [26] Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China
    Lin, H.
    Xu, B.
    Chen, Y.
    Wang, W.
    Journal of Applied Microbiology, 2009, 106 (02): : 606 - 612
  • [27] Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait
    Al-Matawah, Qadreyah
    Al-Zenki, Sameer
    Al-Azmi, Ahmad
    Al-Waalan, Tahani
    Al-Salameen, Fadila
    Ben Hejji, Ahmad
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (13) : 10235 - 10241
  • [28] Operating cooling water systems without the use of biocides: Cost-efficient and environmentally friendly water treatment for cooling systems
    Havighorst, Lars
    Lindemann, Eduard
    CIT Plus, 2023, 26 (10) : 34 - 35
  • [29] Safe corrosion inhibitor for treating cooling water on heat power engineering plants
    Nikolaeva L.A.
    Khasanova D.I.
    Mukhutdinova E.R.
    Safin D.K.
    Sharifullin I.G.
    Thermal Engineering, 2017, 64 (8) : 623 - 625
  • [30] Structural Engineering Challenges in Structures for Cooling Water System in Thermal Power Plant
    Trivedi, Dipal P.
    Bagga, Raja I.
    Chokshi, Jignesh V.
    CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 141 - 150