Endothelial damage of a donor cornea depending on the donor insertion method during Descemet-stripping automated endothelial keratoplasty in porcine eyes

被引:8
|
作者
Hwang, Hosik [1 ]
Kim, Mansoo [1 ]
机构
[1] Catholic Univ Korea, Dept Ophthalmol, Coll Med, Kangnam St Marys Hosp, Seoul 137040, South Korea
关键词
corneal endothelium; Descemet-stripping automated endothelial keratoplasty; donor insertion; porcine eye; taco technique; VISUAL-ACUITY; TRANSPLANTATION; MEMBRANE; SERIES; DSAEK;
D O I
10.1007/s10384-009-0713-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare endothelial damage of the donor cornea in relation to the method of inserting the donor cornea into the recipient anterior chamber during Descemet-stripping automated endothelial keratoplasty (DSAEK). Fifteen enucleated pig eyes were used. The donor corneoscleral buttons were mounted in an artificial anterior chamber. The anterior lamella was excised using a microkeratome and punched using a trephine. The following methods were employed to insert the donor cornea into the recipient anterior chamber: (1) The donor was folded over, grasped using forceps, and inserted ("taco" technique). (2) The forceps were inserted and the edge of the donor was grasped and dragged into the chamber. (3) A loop was made at the edge of the donor by suturing with nylon. A hook was inserted to drag the donor by the loop into the chamber. After insertion, the incision on the recipient eye was extended, and the donor cornea was removed for examination. After vital staining, the samples were examined under a light microscope and a scanning electron microscope. With the taco technique, endothelial damage (17.9%) was observed in areas where the forceps held the donor. In the drag technique using forceps, endothelial damage (17.3%) was observed where the forceps made contact and in the folds in this area. In the drag technique using a suture, endothelial damage (18.8%) was observed in the area of the needle puncture and in folds in this area. The amount of endothelial damage did not differ significantly among the three different methods of donor insertion during DSAEK in this animal model, but each method exhibited a different endothelial damage pattern.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 50 条
  • [41] Donor Cornea Tissue With Prior Radial Keratotomy: Is it Suitable for Descemet Stripping Automated Endothelial Keratoplasty? Reply
    Terry, Mark A.
    Phillips, Paul M.
    CORNEA, 2011, 30 (09) : 1062 - 1062
  • [42] Descemet-stripping automated endothelial keratoplasty donor tissue preparation using the double-pass microkeratome technique
    Waite, Aaron
    Davidson, Richard
    Taravella, Michael J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03): : 446 - 450
  • [43] Descemet-stripping automated endothelial keratoplasty: a successful alternative to repeat penetrating keratoplasty
    Lee, Bryan S.
    Stark, Walter J.
    Jun, Albert S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (03): : 195 - 200
  • [44] Ischemic optic neuropathy after Descemet-stripping automated endothelial keratoplasty
    Rosenberg, Christopher R.
    Weissbart, Sarah B.
    Sibony, Patrick A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12): : E8 - E10
  • [45] Descemet Membrane Endothelial Keratoplasty versus Descemet Stripping Automated Endothelial Keratoplasty in Complicated Vitrectomized Eyes
    Mimouni, Michael
    Sorkin, Nir
    Slomovic, Jacqueline
    Kisilevsky, Eli
    Mednick, Zale
    Cohen, Eyal
    Trinh, Tanya
    Santaella, Gisella
    Chan, Clara C.
    Rootman, David S.
    Slomovic, Allan R.
    CURRENT EYE RESEARCH, 2021, 46 (09) : 1283 - 1290
  • [46] Descemet Stripping Automated Endothelial Keratoplasty Performed by Cornea Fellows
    Hashemi, Hassan
    Asghari, Hossein
    Amanzadeh, Kazem
    Behrooz, Mahmood Jabarvand
    Beheshtnejad, Amirhooshang
    Mohammadpour, Mehrdad
    CORNEA, 2012, 31 (09) : 974 - 977
  • [47] Modification in Descemet-stripping automated endothelial keratoplasty - "Hitch suture" technique
    Vajpayee, Rasik B.
    Agarwal, Tushar
    Jhanji, Vishal
    Sharma, Namrata
    CORNEA, 2006, 25 (09) : 1060 - 1062
  • [48] Late detachment of donor graft after Descemet stripping automated endothelial keratoplasty
    Busin, Massimo
    Bhatt, Priya R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01): : 159 - 160
  • [49] Presoaking Donor Cornea Reduces Graft Detachment Rates in Descemet Stripping Endothelial Keratoplasty
    Lee, Jimmy K.
    Stark, Walter J.
    Gottsch, John D.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (03) : 472 - 473
  • [50] Outcomes of Descemet Membrane Endothelial Keratoplasty in Eyes With a Previous Descemet Stripping Automated Endothelial Keratoplasty Graft
    Sorkin, Nir
    Showail, Mahmood
    Einan-Lifshitz, Adi
    Boutin, Tanguy
    Borovik, Armand
    Kreimei, Mohammad
    Rosenblatt, Amir
    Chan, Clara C.
    Rootman, David S.
    CORNEA, 2018, 37 (06) : 678 - 681