Endothelial damage of a donor cornea depending on the donor insertion method during Descemet-stripping automated endothelial keratoplasty in porcine eyes

被引:8
|
作者
Hwang, Hosik [1 ]
Kim, Mansoo [1 ]
机构
[1] Catholic Univ Korea, Dept Ophthalmol, Coll Med, Kangnam St Marys Hosp, Seoul 137040, South Korea
关键词
corneal endothelium; Descemet-stripping automated endothelial keratoplasty; donor insertion; porcine eye; taco technique; VISUAL-ACUITY; TRANSPLANTATION; MEMBRANE; SERIES; DSAEK;
D O I
10.1007/s10384-009-0713-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare endothelial damage of the donor cornea in relation to the method of inserting the donor cornea into the recipient anterior chamber during Descemet-stripping automated endothelial keratoplasty (DSAEK). Fifteen enucleated pig eyes were used. The donor corneoscleral buttons were mounted in an artificial anterior chamber. The anterior lamella was excised using a microkeratome and punched using a trephine. The following methods were employed to insert the donor cornea into the recipient anterior chamber: (1) The donor was folded over, grasped using forceps, and inserted ("taco" technique). (2) The forceps were inserted and the edge of the donor was grasped and dragged into the chamber. (3) A loop was made at the edge of the donor by suturing with nylon. A hook was inserted to drag the donor by the loop into the chamber. After insertion, the incision on the recipient eye was extended, and the donor cornea was removed for examination. After vital staining, the samples were examined under a light microscope and a scanning electron microscope. With the taco technique, endothelial damage (17.9%) was observed in areas where the forceps held the donor. In the drag technique using forceps, endothelial damage (17.3%) was observed where the forceps made contact and in the folds in this area. In the drag technique using a suture, endothelial damage (18.8%) was observed in the area of the needle puncture and in folds in this area. The amount of endothelial damage did not differ significantly among the three different methods of donor insertion during DSAEK in this animal model, but each method exhibited a different endothelial damage pattern.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 50 条
  • [31] Descemet-stripping automated endothelial keratoplasty in eyes with transscleral-sutured intraocular lenses
    Yazu, Hiroyuki
    Yamaguchi, Takefumi
    Dogru, Murat
    Ishii, Nobuhito
    Satake, Yoshiyuki
    Shimazaki, Jun
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (06): : 846 - 854
  • [32] Epithelial ingrowth after Descemet-stripping automated endothelial keratoplasty
    Koenig, Steven B.
    Covert, Douglas J.
    CORNEA, 2008, 27 (06) : 727 - 729
  • [33] Busin Guide vs Forceps for the Insertion of the Donor Lenticule in Descemet Stripping Automated Endothelial Keratoplasty
    Bahar, Irit
    Kaiserman, Igor
    Sansanayudh, Wiwan
    Levinger, Eliya
    Rootman, David S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) : 220 - 226
  • [34] Detachment of Donor Graft After Descemet Stripping Automated Endothelial Keratoplasty
    Sykakis, Evripidis
    Georgoudis, Panagiotis
    Hamada, Samer
    Lake, Damian
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : e143259
  • [35] Descemet Stripping Automated Endothelial Keratoplasty Using Infant Donor Tissue
    Kim, Peter
    Yeung, Sonia N.
    Lichtinger, Alejandro
    Amiran, Maoz D.
    Rootman, David S.
    CORNEA, 2012, 31 (01) : 52 - 54
  • [36] Flipping the Inverted Donor Disk in Descemet Stripping Automated Endothelial Keratoplasty
    Hashemi, Hassan
    Shamshiri, Mehrdad
    Mehravaran, Shiva
    CORNEA, 2009, 28 (02) : 214 - 216
  • [37] Retrephination of Eccentric Donor Graft for Descemet Stripping Automated Endothelial Keratoplasty
    Kymionis, George D.
    Diakonis, Vasilios F.
    Papathanasiou, Miltiadis
    Yoo, Sonia H.
    CORNEA, 2011, 30 (09) : 1058 - 1060
  • [38] Epithelial downgrowth after Descemet-stripping automated endothelial keratoplasty
    Phillips, Paul M.
    Terry, Mark A.
    Kaufman, Stephen C.
    Chen, Edwin S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01): : 193 - 196
  • [39] Outcomes of Descemet-Stripping Automated Endothelial Keratoplasty in Congenital Hereditary Endothelial Dystrophy
    Mohebbi, Masoomeh
    Nabavi, Amin
    Fadakar, Kaveh
    Hashemi, Hassan
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 57 - 62
  • [40] Retained nuclear fragment found during Descemet-stripping automated endothelial keratoplasty
    Mifflin, Mark D.
    Neuffer, Marcus C.
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 608 - 610