Variability of microcirculatory measurements in healthy volunteers

被引:4
|
作者
Bol, M. E. [1 ,2 ]
Broddin, B. E. K. [1 ]
Delhaas, T. [3 ]
Sels, J. E. M. [1 ,4 ,5 ]
van de Poll, M. C. G. [1 ,2 ,6 ]
机构
[1] Maastricht Univ, Dept Intens Care Med, MUMC, Med Ctr, Maastricht, Netherlands
[2] Maastricht Univ, Sch Nutr & Translat Res Metab NUTRIM, Maastricht, Netherlands
[3] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Dept Biomed Engn, Maastricht, Netherlands
[4] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[5] Maastricht Univ, Dept Cardiol, MUMC, Med Ctr, Maastricht, Netherlands
[6] Maastricht Univ, Dept Surg, MUMC, Med Ctr, Maastricht, Netherlands
关键词
ENDOTHELIAL GLYCOCALYX THICKNESS; MICROVASCULAR DYSFUNCTION; SEPTIC SHOCK; SEPSIS;
D O I
10.1038/s41598-022-22947-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Reliable assessment of the microcirculation is important to investigate microcirculatory properties in various disease states. The GlycoCheck system automatically analyzes sublingual sidestream dark field images to determine the perfused boundary region (PBR; a measure of glycocalyx thickness), red blood cell filling percentage, and microvascular vessel density. Although GlycoCheck has been used to study the microcirculation in patients, little is known about the reproducibility of measurements in healthy volunteers. We assessed intra- and interobserver agreement by having two experienced observers perform three consecutive microcirculation measurements with the GlycoCheck system in 49 healthy volunteers. Intraobserver agreement of single measurements were poor (intraclass correlation coefficients (ICCs) < 0.4) for PBR, red blood cell filling percentage and microvascular vessel density. ICCs increased to values > 0.6 (indicating good reproducibility) for all parameters when performing and averaging three consecutive measurements. No systematic differences were observed between observers for any parameter. Interobserver variability was fair for PBR (ICC = 0.53) and red blood cell filling percentage (ICC = 0.58) and poor for perfused vessel density (ICC = 0.20). In conclusion, GlycoCheck software can be used with acceptable reliability and reproducibility for microcirculation measurements on a population level when averaging three consecutive measurements. Repeated measurements are preferably performed by the same observer.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] ACTION OF TOLMESOXIDE ON CERTAIN CARDIOVASCULAR MEASUREMENTS IN HEALTHY-HUMAN VOLUNTEERS
    BUYLLA, JA
    CLIFFORD, JM
    WYNNE, RD
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1979, 8 (04) : P402 - P402
  • [42] Influence of academic examination stress on hematological measurements in subjectively healthy volunteers
    Maes, M
    Van der Planken, M
    Van Gastel, A
    Bruyland, K
    Van Hunsel, F
    Neels, H
    Hendriks, D
    Wauters, A
    Demedts, P
    Janca, A
    Scharpé, S
    PSYCHIATRY RESEARCH, 1998, 80 (03) : 201 - 212
  • [43] Microvascular function in healthy volunteers; a comparison of manually and automatically derived measurements
    Rook, W.
    Charlton, M.
    Thompson, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 120 (05) : E19 - E19
  • [44] VARIABILITY IN MEASUREMENTS OF PULMONARY MECHANICS IN HEALTHY TERM NEONATES
    GUPTA, S
    JOHNSON, K
    HENDRICKER, C
    THIES, D
    WAGENER, J
    ERENBERG, A
    PEDIATRIC RESEARCH, 1989, 25 (04) : A311 - A311
  • [45] REPRODUCIBILITY OF QT(C)-MEASUREMENTS IN HEALTHY-VOLUNTEERS .1.
    VERVAET, P
    AMERY, W
    ACTA CARDIOLOGICA, 1993, 48 (06) : 555 - 564
  • [46] STROKE VOLUME MEASUREMENTS BY ELECTRICAL BIOIMPEDANCE AND ECHOCARDIOGRAPHY IN HEALTHY-VOLUNTEERS
    HUANG, KC
    STODDARD, M
    TSUEDA, K
    HEINE, MF
    THOMAS, MH
    WHITE, M
    WIEMAN, TJ
    CRITICAL CARE MEDICINE, 1990, 18 (11) : 1274 - 1278
  • [47] VARIABILITY IN MEASUREMENTS OF PULMONARY MECHANICS IN HEALTHY TERM NEONATES
    GUPTA, S
    JOHNSON, K
    HENDRICKER, C
    THIES, D
    WAGENER, J
    ERENBERG, A
    CLINICAL RESEARCH, 1988, 36 (06): : A905 - A905
  • [48] Comparing right ventricular measurements in healthy dutch volunteers with the current guidelines
    Van der Zwaan, H. B.
    Helbing, W. A.
    Geleijnse, M. L.
    McGhie, J. S.
    Roos-Hesselink, J. W.
    Meijboom, F. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 754 - 754
  • [49] Lack of Circadian Variation of Pulse Wave Velocity Measurements in Healthy Volunteers
    Drager, Luciano F.
    Diegues-Silva, Luzia
    Diniz, Patricia M.
    Lorenzi-Filho, Geraldo
    Krieger, Eduardo M.
    Bortolotto, Luiz A.
    JOURNAL OF CLINICAL HYPERTENSION, 2011, 13 (01): : 19 - 22
  • [50] Simultaneous blood perfusion and fluorescence lifetime measurements in skin of healthy volunteers
    Stelmashchuk, O. A.
    Shupletsov, V. V.
    Dunaev, A., V
    Zherebtsov, E. A.
    TRANSLATIONAL BIOPHOTONICS: DIAGNOSTICS AND THERAPEUTICS, 2021, 11919