Variability of microcirculatory measurements in healthy volunteers

被引:4
|
作者
Bol, M. E. [1 ,2 ]
Broddin, B. E. K. [1 ]
Delhaas, T. [3 ]
Sels, J. E. M. [1 ,4 ,5 ]
van de Poll, M. C. G. [1 ,2 ,6 ]
机构
[1] Maastricht Univ, Dept Intens Care Med, MUMC, Med Ctr, Maastricht, Netherlands
[2] Maastricht Univ, Sch Nutr & Translat Res Metab NUTRIM, Maastricht, Netherlands
[3] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Dept Biomed Engn, Maastricht, Netherlands
[4] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[5] Maastricht Univ, Dept Cardiol, MUMC, Med Ctr, Maastricht, Netherlands
[6] Maastricht Univ, Dept Surg, MUMC, Med Ctr, Maastricht, Netherlands
关键词
ENDOTHELIAL GLYCOCALYX THICKNESS; MICROVASCULAR DYSFUNCTION; SEPTIC SHOCK; SEPSIS;
D O I
10.1038/s41598-022-22947-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Reliable assessment of the microcirculation is important to investigate microcirculatory properties in various disease states. The GlycoCheck system automatically analyzes sublingual sidestream dark field images to determine the perfused boundary region (PBR; a measure of glycocalyx thickness), red blood cell filling percentage, and microvascular vessel density. Although GlycoCheck has been used to study the microcirculation in patients, little is known about the reproducibility of measurements in healthy volunteers. We assessed intra- and interobserver agreement by having two experienced observers perform three consecutive microcirculation measurements with the GlycoCheck system in 49 healthy volunteers. Intraobserver agreement of single measurements were poor (intraclass correlation coefficients (ICCs) < 0.4) for PBR, red blood cell filling percentage and microvascular vessel density. ICCs increased to values > 0.6 (indicating good reproducibility) for all parameters when performing and averaging three consecutive measurements. No systematic differences were observed between observers for any parameter. Interobserver variability was fair for PBR (ICC = 0.53) and red blood cell filling percentage (ICC = 0.58) and poor for perfused vessel density (ICC = 0.20). In conclusion, GlycoCheck software can be used with acceptable reliability and reproducibility for microcirculation measurements on a population level when averaging three consecutive measurements. Repeated measurements are preferably performed by the same observer.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Intersession Repeatability of Acoustic Rhinometry Measurements in Healthy Volunteers
    Al Ahmari, Mohammed Dhafer
    Wedzicha, Jadwiga Anna
    Hurst, John Robert
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2012, 5 (03) : 156 - 160
  • [22] MICROCIRCULATORY STUDIES IN HEALTHY-VOLUNTEERS AFTER ULNAR BLOCKADE AS A MODEL FOR THE EFFECT OF DIABETIC NEUROPATHY
    NETTEN, PM
    WOLLERSHEIM, H
    GIELEN, MJM
    DENAREND, JACJ
    THIEN, T
    LUTTERMAN, JA
    DIABETOLOGIA, 1993, 36 : A70 - A70
  • [23] Individual variability of healthy volunteers to the neuropsychological effects of lamotrigine and topiramate
    Meador, KJ
    Loring, DW
    Fessler, AJ
    Werz, MA
    Ray, PG
    Vahle, VJ
    Schoenberg, MR
    EPILEPSIA, 2004, 45 : 176 - 177
  • [24] Variability in concentration and glucodynamic profiles of insulin glargine in healthy volunteers
    Becker, R. H. A.
    Frick, A. D.
    Nosek, L.
    Heinemann, L.
    Heise, T.
    Rave, K.
    DIABETOLOGIA, 2006, 49 : 622 - 622
  • [25] Description of mitochondrial oxygen tension and its variability in healthy volunteers
    Baysan, Meryem
    Broere, Mark
    Wille, Maarten E.
    Bergsma, Jule E.
    Mik, Egbert G.
    Juffermans, Nicole P.
    Tsonaka, Roula
    van der Bom, Johanna G.
    Arbous, Sesmu M.
    PLOS ONE, 2024, 19 (06):
  • [26] Variability in concentration and glucodynamic profiles of insulin glargine in healthy volunteers
    Becker, RHA
    Frick, AD
    Saoud, JB
    Nosek, L
    Heinemann, L
    Heise, T
    Rave, K
    DIABETES, 2005, 54 : A145 - A145
  • [27] Components of day-to-day variability of cerebral perfusion measurements - Analysis of phase contrast mapping magnetic resonance imaging measurements in healthy volunteers
    Ismaili, Abd R. A.
    Vestergaard, Mark B.
    Hansen, Adam E.
    Larsson, Henrik B. W.
    Johannesen, Helle H.
    Law, Ian
    Henriksen, Otto M.
    PLOS ONE, 2018, 13 (06):
  • [28] Intra-and inter-observer variability of point of care ultrasound measurements to evaluate hemodynamic parameters in healthy volunteers
    Deborah Blanca
    Esther C. Schwarz
    Tycho Joan Olgers
    Ewoud ter Avest
    Nasim Azizi
    Hjalmar R. Bouma
    Jan Cornelis Ter Maaten
    The Ultrasound Journal, 15
  • [29] Intra-and inter-observer variability of point of care ultrasound measurements to evaluate hemodynamic parameters in healthy volunteers
    Blanca, Deborah
    Schwarz, Esther C.
    Olgers, Tycho Joan
    ter Avest, Ewoud
    Azizi, Nasim
    Bouma, Hjalmar R.
    Ter Maaten, Jan Cornelis
    ULTRASOUND JOURNAL, 2023, 15 (01):
  • [30] Reassessing the accuracy and reproducibility of Diers formetric measurements in healthy volunteers
    Lason, Gregoire
    Peeters, Luc
    Vandenberghe, Koen
    Byttebier, Geert
    Comhaire, Frank
    INTERNATIONAL JOURNAL OF OSTEOPATHIC MEDICINE, 2015, 18 (04) : 247 - 254