An optimized engineering design of imaging probe for time-resolved diffuse optical tomography system

被引:0
|
作者
Chen, Ling [1 ]
Hasnain, Ali [1 ]
Chen, Nanguang [1 ]
机构
[1] Natl Univ Singapore, Dept Bioengn, Opt Bioimaging Lab, 7 Engn Dr 1, Singapore 117574, Singapore
关键词
Time-resolved diffuse optical tomography; Cramer-Rao lower bound; optimization of source-detector arrangements; experimental verification; RESOLUTION; BRAIN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We proposed an optimized engineering design of an imaging probe for time-resolved diffuse optical tomography system to increase the sensitivity of signal detection from tested objects. With limited number of sources and detectors, we considered an automatic rotational probe to generate more measurement pairs as well as more detection angles, compared to probes with equal number of sources and detectors. We also considered optimizing the arrangements of sources and detectors on the imaging probe to collect more information from the tested domain than those random arrangements. The method for selecting optimized sources' and detectors' positions is based on Cramer-Rao lower bound. Image reconstruction results of semi-infinite domain using phantom experimental data from different patterns of source and detector arrangements are presented. We demonstrated that the optimized source and detector arrangements chosen based on the reconstruction results match the choices from the optimized selecting methods. Thus we selected the optimized sets for the imaging probe.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A self-normalized, full time-resolved method for fluorescence diffuse optical tomography
    Gao, Feng
    Zhao, Huijuan
    Zhang, Limin
    Tanikawa, Yukari
    Marjono, Andhi
    Yamada, Yukio
    OPTICS EXPRESS, 2008, 16 (17): : 13104 - 13121
  • [42] Neuroimaging technique using time-resolved diffuse optical tomography and inhomogeneity localization algorithm
    Potlov, A. Yu
    Frolov, S., V
    Proskurin, S. G.
    SARATOV FALL MEETING 2018: OPTICAL AND NANO-TECHNOLOGIES FOR BIOLOGY AND MEDICINE, 2019, 11065
  • [43] Time-resolved diffuse optical tomography using a modified generalized pulse spectrum technique
    Inst. for Human Sci./Biomed. Eng., National Institute of AIST, Tsukuba-shi 305-8564, Japan
    不详
    IEICE Trans Inf Syst, 1 (133-142):
  • [44] Time-resolved diffuse optical tomography using a modified generalized pulse spectrum technique
    Gao, F
    Zhao, HJ
    Tanikawa, Y
    Yamada, Y
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2002, E85D (01) : 133 - 142
  • [45] Time-resolved diffuse optical tomography system based on adaptive structured lighti llumination and compressive sensing detection
    Farina, Andrea
    Betcke, Marta
    Bassi, Andrea
    Valentini, Gianluca
    Arridge, Simon
    D'Andrea, Cosimo
    UNCONVENTIONAL OPTICAL IMAGING, 2018, 10677
  • [46] Experimental study on time-resolved optical tomography
    Gao, Feng
    Zint, C.V.
    Poulet, P.
    Guangxue Xuebao/Acta Optica Sinica, 2001, 21 (09): : 1068 - 1072
  • [47] Portable, large-bandwidth time-resolved system for diffuse optical spectroscopy
    Bassi, Andrea
    Farina, Andrea
    D'Andrea, Cosimo
    Pifferi, Antonio
    Valentini, Gianluca
    Cubeddu, Rinaldo
    OPTICS EXPRESS, 2007, 15 (22): : 14482 - 14487
  • [48] Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography
    Okawa, S.
    Endo, Y.
    Hoshi, Y.
    Yamada, Y.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (01) : 69 - 78
  • [49] Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography
    S. Okawa
    Y. Endo
    Y. Hoshi
    Y. Yamada
    Medical & Biological Engineering & Computing, 2012, 50 : 69 - 78
  • [50] Compact dual-wavelength system for time-resolved diffuse optical spectroscopy
    Renna, Marco
    Buttafava, Mauro
    Zappa, Franco
    Tosi, Alberto
    Martinenghi, Edoardo
    Zanoletti, Marta
    Dalla Mora, Alberto
    Pifferi, Antonio
    Torricelli, Alessandro
    Contini, Davide
    2017 13TH CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIME), 2017, : 293 - 296