An optimized engineering design of imaging probe for time-resolved diffuse optical tomography system

被引:0
|
作者
Chen, Ling [1 ]
Hasnain, Ali [1 ]
Chen, Nanguang [1 ]
机构
[1] Natl Univ Singapore, Dept Bioengn, Opt Bioimaging Lab, 7 Engn Dr 1, Singapore 117574, Singapore
关键词
Time-resolved diffuse optical tomography; Cramer-Rao lower bound; optimization of source-detector arrangements; experimental verification; RESOLUTION; BRAIN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We proposed an optimized engineering design of an imaging probe for time-resolved diffuse optical tomography system to increase the sensitivity of signal detection from tested objects. With limited number of sources and detectors, we considered an automatic rotational probe to generate more measurement pairs as well as more detection angles, compared to probes with equal number of sources and detectors. We also considered optimizing the arrangements of sources and detectors on the imaging probe to collect more information from the tested domain than those random arrangements. The method for selecting optimized sources' and detectors' positions is based on Cramer-Rao lower bound. Image reconstruction results of semi-infinite domain using phantom experimental data from different patterns of source and detector arrangements are presented. We demonstrated that the optimized source and detector arrangements chosen based on the reconstruction results match the choices from the optimized selecting methods. Thus we selected the optimized sets for the imaging probe.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Diffuse optical tomography using. time-resolved photon path distribution
    Ueda, Y
    Ohta, K
    Yamashita, Y
    OPTICAL REVIEW, 2005, 12 (04) : 334 - 337
  • [32] Time-resolved diffuse optical tomography with patterned-light illumination and detection
    Chen, Jin
    Venugopal, Vivek
    Lesage, Frederic
    Intes, Xavier
    OPTICS LETTERS, 2010, 35 (13) : 2121 - 2123
  • [33] Diffuse optical fluorescence tomography using time-resolved data acquired in transmission
    Leblond, Frederic
    Fortier, Simon
    Friedlander, Michael P.
    MULTIMODAL BIOMEDICAL IMAGING II, 2007, 6431
  • [34] An algorithm for localization of optical disturbances in turbid media using time-resolved diffuse optical tomography
    Potlov, A. Yu.
    Frolov, S. V.
    Proskurin, S. G.
    SARATOV FALL MEETING 2017: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XIX, 2018, 10716
  • [35] Full time-resolved scheme data in time-domain fluorescence diffuse optical tomography
    Marjono, Andhi
    Yano, Akira
    Okawa, Shinpei
    Gao, Feng
    Yamada, Yukio
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [36] Diffuse Imaging: Creating Optical Images With Unfocused Time-Resolved Illumination and Sensing
    Kirmani, Ahmed
    Jeelani, Haris
    Montazerhodjat, Vahid
    Goyal, Vivek K.
    IEEE SIGNAL PROCESSING LETTERS, 2012, 19 (01) : 31 - 34
  • [37] Fluorescence time-resolved imaging system embedded in an ultrasound prostate probe
    Laidevant, Aurelie
    Herve, Lionel
    Debourdeau, Mathieu
    Boutet, Jerome
    Grenier, Nicolas
    Dinten, Jean-Marc
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (01): : 194 - 206
  • [38] Time Resolved Diffuse Optical Tomography model
    Kazanci, Huseyin Ozgur
    OPTIK, 2018, 162 : 133 - 139
  • [39] Improvement of image quality in diffuse optical tomography by use of full time-resolved data
    Gao, F
    Zhao, HJ
    Yamada, Y
    APPLIED OPTICS, 2002, 41 (04) : 778 - 791
  • [40] A self-normalized, full time-resolved scheme for fluorescence diffuse optical tomography
    Gao, Feng
    Zhang, Limin
    He, Huiyuan
    Zhao, Huijuan
    Jiang, Jingying
    Tanikawa, Yukari
    Maijono, Andhi
    Yamada, Yukio
    MULTIMODAL BIOMEDICAL IMAGING III, 2008, 6850