Monte Carlo-based analysis of PET scatter components

被引:0
|
作者
Adam, LE
Bellemann, ME
Brix, G
Lorenz, WJ
机构
关键词
PET; scatter components; scatter correction; Monte Carlo simulations;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study quantifies the different scatter components in PET and examines how the different components degrade reconstructed PET images, Methods: We simulated the measurement of various phantoms using Monte Carlo (MC) calculations and compared the MC-generated projections and images with the corresponding experimental data, The coincidences were subdivided in four classes: primaries, object scatter (scattered in the object only), gantry scatter (scattered in the scanner only) and mixed scatter (scattered both in the object and the scanner). Results: In the projections of the line sources, the gantry scatter was closely located around the source position, whereas the object scatter was smeared over the whole field of view and could be parameterized well by a monoexponential function, The mixed scatter had nearly the same distribution as the object scatter, but with a smaller amplitude. The calculations and experimental data were in excellent agreement; i.e., led to the same parameterization of the scatter distribution functions and to a similar localization of the scatter components in the reconstructed images, Conclusion: The spatial distribution of the scatter components justifies the widely-used assumption that it is sufficient to restrict experimental scatter correction techniques to the object scatter, Furthermore, it is possible to derive the parameters for the scatter kernels, which are needed for the convolution-subtraction algorithm, by MC simulations.
引用
收藏
页码:2024 / 2029
页数:6
相关论文
共 50 条
  • [21] Monte Carlo-based tail exponent estimator
    Barunik, Jozef
    Vacha, Lukas
    [J]. PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2010, 389 (21) : 4863 - 4874
  • [22] Monte Carlo-based food irradiation simulator
    Kim, J
    Moreira, RG
    Rivadeneira, R
    Castell-Perez, ME
    [J]. JOURNAL OF FOOD PROCESS ENGINEERING, 2006, 29 (01) : 72 - 88
  • [23] Monte Carlo-based inverse treatment planning
    Jeraj, R
    Keall, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : 1885 - 1896
  • [24] Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
    Beekman, FJ
    de Jong, HWAM
    van Geloven, S
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) : 867 - 877
  • [25] Half-time myocardial perfusion SPECT imaging with attenuation and Monte Carlo-based scatter correction
    Kangasmaa, T.
    Kuikka, J.
    Vanninen, E.
    Mussalo, H.
    Laitinen, T.
    Sohlberg, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S204 - S204
  • [26] PET-SORTEO: A Monte Carlo-based simulator with high count rate capabilities
    Reilhac, A
    Lartizien, C
    Costes, N
    Sans, S
    Comtat, C
    Gunn, RN
    Evans, AC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 46 - 52
  • [27] Half-time myocardial perfusion SPECT imaging with attenuation and Monte Carlo-based scatter correction
    Kangasmaa, Tuija S.
    Kuikka, Jyrki T.
    Vanninen, Esko J.
    Mussalo, Hanna M.
    Laitinen, Tomi P.
    Sohlberg, Antti O.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (11) : 1040 - 1045
  • [28] A new Monte Carlo-based fitting method
    Pedroni, P.
    Sconfietti, S.
    [J]. JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2020, 47 (05)
  • [29] A New Sampling Technique for Monte Carlo-based Statistical Circuit Analysis
    Mahmoudi, Hiwa
    Zimmermann, Horst
    [J]. PROCEEDINGS OF THE 2017 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2017, : 1277 - 1280
  • [30] Characterization of the ringing artifacts in rotator-based reconstruction with Monte Carlo-based resolution compensation for PET
    Zhang, Long
    Staelens, Steven
    Van Holen, Roel
    Verhaeghe, Jeroen
    Vandenberghe, Stefaan
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 4648 - 4660