Performance evaluation of discharge plasma process for gaseous pollutant removal

被引:144
|
作者
Kim, HH
Prieto, G
Takashima, K
Katsura, S
Mizuno, A
机构
[1] Toyohashi Univ Technol, Dept Ecol Engn, Toyohashi, Aichi 4418580, Japan
[2] Univ Nacl Tucuman, Dept Chem Engn, RA-4000 San Miguel De Tucuman, Tucuman, Argentina
关键词
non-thermal plasma; pulse corona discharge; scaling rule; energy constant; nitric oxide;
D O I
10.1016/S0304-3886(01)00182-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Performance evaluation of non-thermal plasma (NTP) process has been carried out using NO as a model gas. The experimental results were evaluated using a simple model, which relates the change of NO concentration with specific input energy (SIE) (kJ/Nm(3)). The results were also evaluated using the well-known parameters of energy cost, energy yield (EY) and G-value. As the SIE increased, the EY and the G-value decreased while the energy cost increased even under a given reaction condition. Based on these parameters best results were found in the smaller SIE region where the NO removal is poor. An approach has been developed to use the constant (hereafter referred to as energy constant k(E) (Nm(3)/kJ)) in a simple model to evaluate the system performance of non-thermal plasma reactor instead of conventional parameters. Unlike the three conventional parameters, the energy constant was not influenced by the SIE level under the range tested in the present work. The effects of various reaction conditions, such as initial concentration of NO, temperature, additive on the energy constant k(E) have been investigated. The comparison of k(E) values for different NO concentrations clearly showed that the NTP process is more efficient in treating gaseous pollutant in low concentration. The increase of NO concentration exponentially decreased the energy constant. Gas temperature showed a similar effect. The significance of the influence of the tested parameters on the energy constant k(E) has been found to be of the order of the gas composition, the initial concentration, and the gas temperature. Among the additives tested in this study, ethylene made the energy constant k(E) to a maximum value of 242 x 10(-3). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 41
页数:17
相关论文
共 50 条
  • [21] TREATMENT OF GASEOUS EFFLUENTS BY USING SURFACE DISCHARGE PLASMA IN CONTINUOUS REACTORS: PROCESS MODELLING AND SIMULATION
    Assadi, Aymen Amine
    Bouzaza, Abdelkrim
    Wolbert, Dominique
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2015, 93 (02): : 206 - 212
  • [22] Modeling of hazardous air pollutant removal in the pulsed corona discharge
    Derakhshesh, Marzie
    Abedi, Jalal
    Omidyeganeh, Mohammad
    PHYSICS LETTERS A, 2009, 373 (11) : 1051 - 1057
  • [23] Characteristics of NO and SO2 removal in dielectric barrier discharge plasma process
    Sun, Baomin
    Yin, Shui'e
    Xiao, Haiping
    Gao, Xudong
    Zhou, Zhipei
    Huagong Xuebao/CIESC Journal, 2010, 61 (02): : 469 - 476
  • [24] Afterburner pollutant performance evaluation
    Nanjing Univ of Aeronautics and, Astronautics, Nanjing, China
    Ranshao Kexue Yu Jishu, 3 (231-236):
  • [25] Evaluation of the Performance of the Electrocoagulation Process for the Removal of Water Hardness
    Taumaturgo Medina-Collana, Juan
    Enith Reyna-Mendoza, Gladis
    Alberto Montano-Pisfil, Jorge
    Aurelio Rosales-Huamani, Jimmy
    Javier Franco-Gonzales, Elmar
    Cordova Garcia, Xavier
    SUSTAINABILITY, 2023, 15 (01)
  • [26] ELECTRODE SURFACE PROCESS IN GASEOUS PLASMA
    DZOANH, NT
    SURFACE SCIENCE, 1967, 6 (04) : 422 - &
  • [27] Evaluation of pollutant removal in a constructed irrigation pond
    Tasuku Kato
    Hisao Kuroda
    Hideo Nakasone
    Hirohide Kiri
    Paddy and Water Environment, 2007, 5 : 189 - 199
  • [28] Catalytic removal of gaseous pollutant NO using CO: Catalyst structure and reaction mechanism
    Wang, Yixi
    Xu, Wenqing
    Liu, Huixian
    Chen, Wanrong
    Zhu, Tingyu
    ENVIRONMENTAL RESEARCH, 2024, 246
  • [29] Evaluation of pollutant removal in a constructed irrigation pond
    Kato, Tasuku
    Kuroda, Hisao
    Nakasone, Hideo
    Kiri, Hirohide
    PADDY AND WATER ENVIRONMENT, 2007, 5 (03) : 189 - 199
  • [30] GASEOUS POLLUTANT REMOVAL BY A SINGLE BED CYCLIC ADSORBER WITH SYNCHRONOUS THERMAL CONTACT
    HSU, HH
    WANG, KB
    FAN, LT
    SEPARATION SCIENCE, 1976, 11 (02): : 109 - 132