Accelerated 3D T2 mapping with dictionary-based matching for prostate imaging

被引:16
|
作者
Roccia, Elisa [1 ]
Shankar, Rohini Vidya [1 ]
Neji, Radhouene [1 ,2 ]
Cruz, Gastao [1 ]
Munoz, Camila [1 ]
Botnar, Rene [1 ]
Goh, Vicky [3 ]
Prieto, Claudia [1 ]
Dregely, Isabel [1 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Siemens Healthcare Ltd, Frimley, England
[3] Kings Coll London, Canc Imaging, London, England
基金
英国工程与自然科学研究理事会;
关键词
3T MRI; prostate cancer imaging; quantitative MRI; T-2; mapping; LOW-RANK; MULTIPARAMETRIC MRI; IN-VIVO; CANCER; QUANTIFICATION; RELAXATION; RECONSTRUCTION; PERFORMANCE; RECOVERY;
D O I
10.1002/mrm.27540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a fast and accurate method for 3D T-2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. Methods: 3D high-resolution T-2-weighted images (0.9 x 0.9 x 3 mm(3)) were obtained with a multishot T-2-prepared balanced steady-state free precession (T-2-prep-bSSFP) acquisition sequence using a 3D variable density undersampled Cartesian trajectory. Each T-2-weighted image was reconstructed using total variation regularized sensitivity encoding. A flexible simulation framework based on extended phase graphs generated a dictionary of magnetization signals, which was customized to the proposed sequence. The dictionary was matched to the acquired T-2-weighted images to retrieve quantitative T-2 values, which were then compared to gold-standard spin echo acquisition values using monoexponential fitting. The proposed approach was validated in simulations and a T-1/T-2 phantom, and feasibility was tested in 8 healthy subjects. Results: The simulation analysis showed that the proposed T-2 mapping approach is robust to noise and typically observed T-1 variations. T-2 values obtained in the phantom with T(2)prep-bSSFP and the acquisition-specific, dictionary-based matching were highly correlated with the gold-standard spin echo method (r = 0.99). Furthermore, no differences were observed with the accelerated acquisition compared to the fully sampled acquisition (r = 0.99). T-2 values obtained in prostate peripheral zone, central gland, and muscle in healthy subjects (age, 26 +/- 6 years) were 97 +/- 14, 76 +/- 7, and 36 +/- 3 ms, respectively. Conclusion: 3D quantitative T-2 mapping of the whole prostate can be achieved in 3 minutes.
引用
收藏
页码:1795 / 1805
页数:11
相关论文
共 50 条
  • [41] Accelerated 3D multi-echo spin-echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping
    Trotier, Aurelien J.
    Corbin, Nadege
    Miraux, Sylvain
    Ribot, Emeline J.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1525 - 1539
  • [42] Initial experience with isotropic 3D cardiac T2 mapping for the monitoring of cardiac allograft rejection
    Ruud B van Heeswijk
    Hélène Feliciano
    Mélanie Metrich
    Davide Piccini
    Samuel Rotman
    Juerg Schwitter
    Roger Hullin
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [43] Fast in vivo 23Na imaging and T2* mapping using accelerated 2D-FID UTE magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study
    Alhulail, Ahmad A.
    Xia, Pingyu
    Shen, Xin
    Nichols, Miranda
    Volety, Srijyotsna
    Farley, Nicholas
    Thomas, Micheal Albert
    Nagel, Armin M.
    Dydak, Ulrike
    Emir, Uzay E.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1783 - 1794
  • [44] Comparison of quantitative T2 mapping and diflusion-weighted imaging in the normal and pathologic prostate
    Gibbs, P
    Tozer, DJ
    Liney, GP
    Turnbull, LW
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1054 - 1058
  • [45] Robust Myocardial T2 and T2* Mapping at 3T Using Image-Based Shimming
    Zaman, Arshad
    Higgins, David M.
    Motwani, Manish
    Kidambi, Ananth
    Kouwenhoven, Marc
    Kozerke, Sebastian
    Greenwood, John P.
    Plein, Sven
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) : 1013 - 1020
  • [46] Conformal Mapping-Based 3D Surface Matching and Registration
    Song, Y.
    Zeng, W.
    Liu, C.
    Gu, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 400 - 401
  • [47] MR imaging and T2 mapping of femoral cartilage
    Goodwin, DW
    Dunn, JF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (06) : 1568 - 1569
  • [48] Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner-volume 3D GRASE
    Chan, Rachel W.
    Lau, Angus Z.
    Detzler, Garry
    Thayalasuthan, Vivekanandan
    Nam, Robert K.
    Haider, Masoom A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 466 - 476
  • [49] Study of iron metabolism based on T2*mapping sequences in PI-RADS 3 prostate lesions
    Wenhao, D.
    Guangzheng, L.
    Zhen, T.
    Xuedong, W.
    Yonggang, L.
    Xuefeng, Z.
    Weijie, Z.
    Gang, L.
    Yuhua, H.
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [50] 3D TV Broadcasting over DVB-T/T2
    Navarro Cadavid, Andres
    Andredy Ardila, Carlos
    SISTEMAS & TELEMATICA, 2013, 11 (25): : 51 - 84