摘要
Purpose: To develop a fast and accurate method for 3D T-2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. Methods: 3D high-resolution T-2-weighted images (0.9 x 0.9 x 3 mm(3)) were obtained with a multishot T-2-prepared balanced steady-state free precession (T-2-prep-bSSFP) acquisition sequence using a 3D variable density undersampled Cartesian trajectory. Each T-2-weighted image was reconstructed using total variation regularized sensitivity encoding. A flexible simulation framework based on extended phase graphs generated a dictionary of magnetization signals, which was customized to the proposed sequence. The dictionary was matched to the acquired T-2-weighted images to retrieve quantitative T-2 values, which were then compared to gold-standard spin echo acquisition values using monoexponential fitting. The proposed approach was validated in simulations and a T-1/T-2 phantom, and feasibility was tested in 8 healthy subjects. Results: The simulation analysis showed that the proposed T-2 mapping approach is robust to noise and typically observed T-1 variations. T-2 values obtained in the phantom with T(2)prep-bSSFP and the acquisition-specific, dictionary-based matching were highly correlated with the gold-standard spin echo method (r = 0.99). Furthermore, no differences were observed with the accelerated acquisition compared to the fully sampled acquisition (r = 0.99). T-2 values obtained in prostate peripheral zone, central gland, and muscle in healthy subjects (age, 26 +/- 6 years) were 97 +/- 14, 76 +/- 7, and 36 +/- 3 ms, respectively. Conclusion: 3D quantitative T-2 mapping of the whole prostate can be achieved in 3 minutes.
引用
收藏
页码:1795 / 1805
页数:11
相关论文
共 50 条
  • [31] Robust myocardial T2 and T2* mapping at 3T
    Arshad Zaman
    David M Higgins
    Marc Kouwenhoven
    Ananth Kidambi
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [32] Phase-based T2 mapping with gradient echo imaging
    Wang, Xiaoke
    Hernando, Diego
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 609 - 619
  • [33] An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping
    Keerthivasan, Mahesh Bharath
    Saranathan, Manojkumar
    Johnson, Kevin
    Fu, Zhiyang
    Weinkauf, Craig C.
    Martin, Diego R.
    Bilgin, Ali
    Altbach, Maria I.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 326 - 341
  • [34] Luminal Water Imaging: A New MR Imaging T2 Mapping Technique for Prostate Cancer Diagnosis
    Sabouri, Shirin
    Chang, Silvia D.
    Savdie, Richard
    Zhang, Jing
    Jones, Edward C.
    Goldenberg, S. Larry
    Black, Peter C.
    Kozlowski, Piotr
    RADIOLOGY, 2017, 284 (02) : 451 - 459
  • [35] Free-breathing 3D whole-heart joint T1/T2 mapping and water/fat imaging at 0.55 T
    Si, Dongyue
    Crabb, Michael G.
    Kunze, Karl P.
    Littlewood, Simon J.
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1511 - 1524
  • [36] Dictionary-based through-plane interpolation of prostate cancer T2-weighted MR images
    Jurek, Jakub
    Kocinski, Marek
    Materka, Andrzej
    Losnegard, Are
    Reisaeter, Lars
    Halvorsen, Ole J.
    Beisland, Christian
    Rorvik, Jarle
    Lundervold, Arvid
    2018 SIGNAL PROCESSING: ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS (SPA), 2018, : 168 - 173
  • [37] Accelerated 3D T(2)w-imaging of the prostate with 1-millimeter isotropic resolution in less than 3 minutes
    Shankar, Rohini Vidya
    Roccia, Elisa
    Cruz, Gastao
    Neji, Radhouene
    Botnar, Rene
    Prezzi, Davide
    Goh, Vicky
    Prieto, Claudia
    Dregely, Isabel
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 721 - 731
  • [38] Magnetic resonance imaging in the evaluation of cervical foraminal stenosis: comparison of 3D T2 SPACE with sagittal oblique 2D T2 TSE
    I. Barnaure
    J. Galley
    B. Fritz
    R. Sutter
    Skeletal Radiology, 2022, 51 : 1453 - 1462
  • [39] Magnetic resonance imaging in the evaluation of cervical foraminal stenosis: comparison of 3D T2 SPACE with sagittal oblique 2D T2 TSE
    Barnaure, I
    Galley, J.
    Fritz, B.
    Sutter, R.
    SKELETAL RADIOLOGY, 2022, 51 (07) : 1453 - 1462
  • [40] T2 mapping vs T2 weighted imaging in the detection of myocardial oedema
    Elisa McAlindon
    Peter Weale
    Jessica Harris
    David Smith
    Andreas Baumbach
    Tom Johnson
    Chiara Bucciarelli-Ducci
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)