CARMENES. III: an innovative and challenging cooling system for an ultra-stable NIR spectrograph

被引:3
|
作者
Becerril, S. [1 ]
Lizon, J. L. [2 ]
Sanchez-Carrasco, M. A. [1 ]
Mirabet, E. [1 ,2 ]
Amado, P. [1 ]
Seifer, W. [3 ]
Quirrenbach, A. [3 ]
Mandel, H. [3 ]
Caballero, J. A. [4 ]
Ribas, I. [5 ]
Reiners, A. [6 ]
Abril, M. [1 ]
Antona, R. [1 ]
Cardenas, C. [1 ]
Morales, R. [1 ]
Perez, D. [1 ]
Ramon, A. [1 ]
Rodriguez, E. [1 ]
Herranz, J. [7 ]
机构
[1] CSIC, Inst Astrofis Andalucia, Glorieta Astron S-N, E-18008 Granada, Spain
[2] European So Observ, D-85748 Garching, Germany
[3] ZAH, Landessternwarte, D-69117 Heidelberg, Germany
[4] CSIC, INTA, Ctr Astrobiol, E-28850 Madrid, Spain
[5] CSIC, Inst Ciencia Espai, IEEC, E-08193 Barcelona, Spain
[6] GAU, Inst Astrophys, D-37077 Gottingen, Germany
[7] Proact Res Dev, Colombo, Sri Lanka
关键词
Cooling; stability; thermal performance; cryogenics; large instrument; extrasolar planets; near-infrared instrumentation;
D O I
10.1117/12.928618
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The CARMENES project, which is currently at FDR stage, is a last-generation exoplanet hunter instrument to be installed in the Calar Alto Observatory by 2014. It is split into two different spectrographs: one works within the visual range while the other does it in the NIR range. Both channels need to be extremely stable in terms of mechanical and thermal behavior. Nevertheless, due to the operation temperature of the NIR spectrograph, the thermal stability requirement (+/- 0.07 K in 24 hours; +/- 0.01 K (goal)) becomes actually a major challenge. The solution here proposed consists of a system that actively cools a shield enveloping the optical bench. Thus, the instability produced on the shield temperature is further damped on the optical bench due to the high mass of the latter, as well as the high thermal decoupling between both components, the main heat exchange being produced by radiation. This system -which is being developed with the active collaboration and advice of ESO (Jean-Louis Lizon)- is composed by a previous unit which produces a stable flow of nitrogen gas. The flow so produced goes into the in-vacuum circuitry of the NIR spectrograph and removes the radiative heat load incoming to the radiation shield by means of a group of properly dimensioned heat exchangers. The present paper describes and summarizes the cooling system designed for CARMENES NIR as well as the analyses implemented.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Ultra-stable Nd:YAG ring laser for a space-born LIDAR system
    Hunnekuhl, M
    Burdack, P
    Tröbs, M
    Hinze, U
    Fallnich, C
    Bode, M
    Dölle, O
    Freitag, I
    Danzmann, K
    ADVANCED SOLID-STATE LASERS, PROCEEDINGS, 2002, 68 : 489 - 491
  • [32] First experiment of ultra-stable frequency transfer system via optical fiber in NICT
    Fujieda, M.
    Kumagai, M.
    Gotoh, T.
    Hosokawa, M.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4, 2007, : 840 - 844
  • [33] Comparison of 1.5 μm Ultra-Stable Laser Systems Based on Fiber Noise Suppression System
    Wang Z.
    Jin S.
    Li Y.
    Lin Y.
    Fang Z.
    Lin, Yige (linyige@nim.ac.cn), 1600, Science Press (44):
  • [34] Development of a space-compatible packaging system for an integrated monolithic ultra-stable optical reference
    Zhan, Zhenhai
    Luo, Yingxin
    Yeh, Hsien-Chi
    Li, Hongyin
    Chen, Weilu
    Ren, Chongzhi
    Zeng, Bingcheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (10):
  • [35] Suppressing the relative linewidth of a dual-comb system without using ultra-stable CW lasers
    Zhu, Zebin
    Ni, Kai
    Zhou, Qian
    Wu, Guanhao
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [36] Ultra-stable high average power femtosecond laser system tunable from 1.33 to 20 μm
    Steinle, Tobias
    Moerz, Florian
    Steinmann, Andy
    Giessen, Harald
    OPTICS LETTERS, 2016, 41 (21) : 4863 - 4866
  • [37] Ultra-stable 18 mJ Ti:Sa amplifier system with tunable central wavelength, bandwidth and pulse duration
    Trisorio, A.
    Ruchert, C.
    Ple, F.
    Paul, P. M.
    Hauri, C. P.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [38] Precise orbit determination with inter-satellite links and ultra-stable time for a future satellite navigation system
    Michalak, Grzegorz
    Neumayer, Karl Hans
    Koenig, Rolf
    PROCEEDINGS OF THE 31ST INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS+ 2018), 2018, : 968 - 1001
  • [39] Elimination of the PMD related delay jitter in a fiber stretcher based ultra-stable microwave signal distribution system
    Wang, Xi
    Wei, Wei
    Weng, Xiyi
    Wang, Danyang
    Wei, Jiawang
    Xie, Weilin
    Dong, Yi
    OPTICS EXPRESS, 2021, 29 (25) : 41609 - 41621
  • [40] Ultra-stable Laser System for Next-generation Light-pulse Atom Interferometry MAGIS-100
    Giunta, Michele
    Brekenfeld, Manuel
    Bradler, Maximilian
    Schmidt, Dag
    Fricke, Andreas
    Lessing, Maurice
    Fischer, Marc
    Thom, Joseph
    Hempler, Nils
    Maker, Gareth
    Malcolm, Graeme
    Kovachy, Tim
    Hogan, Jason
    Holzwarth, Ronald
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2021,