CARMENES. III: an innovative and challenging cooling system for an ultra-stable NIR spectrograph

被引:3
|
作者
Becerril, S. [1 ]
Lizon, J. L. [2 ]
Sanchez-Carrasco, M. A. [1 ]
Mirabet, E. [1 ,2 ]
Amado, P. [1 ]
Seifer, W. [3 ]
Quirrenbach, A. [3 ]
Mandel, H. [3 ]
Caballero, J. A. [4 ]
Ribas, I. [5 ]
Reiners, A. [6 ]
Abril, M. [1 ]
Antona, R. [1 ]
Cardenas, C. [1 ]
Morales, R. [1 ]
Perez, D. [1 ]
Ramon, A. [1 ]
Rodriguez, E. [1 ]
Herranz, J. [7 ]
机构
[1] CSIC, Inst Astrofis Andalucia, Glorieta Astron S-N, E-18008 Granada, Spain
[2] European So Observ, D-85748 Garching, Germany
[3] ZAH, Landessternwarte, D-69117 Heidelberg, Germany
[4] CSIC, INTA, Ctr Astrobiol, E-28850 Madrid, Spain
[5] CSIC, Inst Ciencia Espai, IEEC, E-08193 Barcelona, Spain
[6] GAU, Inst Astrophys, D-37077 Gottingen, Germany
[7] Proact Res Dev, Colombo, Sri Lanka
关键词
Cooling; stability; thermal performance; cryogenics; large instrument; extrasolar planets; near-infrared instrumentation;
D O I
10.1117/12.928618
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The CARMENES project, which is currently at FDR stage, is a last-generation exoplanet hunter instrument to be installed in the Calar Alto Observatory by 2014. It is split into two different spectrographs: one works within the visual range while the other does it in the NIR range. Both channels need to be extremely stable in terms of mechanical and thermal behavior. Nevertheless, due to the operation temperature of the NIR spectrograph, the thermal stability requirement (+/- 0.07 K in 24 hours; +/- 0.01 K (goal)) becomes actually a major challenge. The solution here proposed consists of a system that actively cools a shield enveloping the optical bench. Thus, the instability produced on the shield temperature is further damped on the optical bench due to the high mass of the latter, as well as the high thermal decoupling between both components, the main heat exchange being produced by radiation. This system -which is being developed with the active collaboration and advice of ESO (Jean-Louis Lizon)- is composed by a previous unit which produces a stable flow of nitrogen gas. The flow so produced goes into the in-vacuum circuitry of the NIR spectrograph and removes the radiative heat load incoming to the radiation shield by means of a group of properly dimensioned heat exchangers. The present paper describes and summarizes the cooling system designed for CARMENES NIR as well as the analyses implemented.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Challenging the Kauzmann paradox using an ultra-stable perfluoropolymer glass with a fictive temperature below the dynamic VFT temperature
    Amer A. El Banna
    Gregory B. McKenna
    Scientific Reports, 13
  • [22] Ultra-stable counter flow diverging minichannel heat sink with integrated microstructures for superior cooling performance
    Shah, Syed Waqar Ali
    Jiang, Xingchi
    Li, Yuen Kit Howard
    Chen, Gong
    Liu, Jian
    Gao, Yuan
    Zhang, Shiwei
    Pan, Chin
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [23] Neutral Cyanine: Ultra-Stable NIR-II Merocyanines for Highly Efficient Bioimaging and Tumor-Targeted Phototheranostics
    Wan, Yingpeng
    Chen, Weilong
    Liu, Ying
    Lee, Ka-Wai
    Gao, Yijian
    Zhang, Di
    Li, Yuqing
    Huang, Zhongming
    Luo, Jingdong
    Lee, Chun-Sing
    Li, Shengliang
    ADVANCED MATERIALS, 2024, 36 (31)
  • [24] An ultra-stable referenced interrogation system in the deep ultraviolet for a mercury optical lattice clock
    S. T. Dawkins
    R. Chicireanu
    M. Petersen
    J. Millo
    D. V. Magalhães
    C. Mandache
    Y. Le Coq
    S. Bize
    Applied Physics B, 2010, 99 : 41 - 46
  • [25] Evaluation of an ultra-stable laser system based on a linewidth transfer method for optical clocks
    Hosaka, Kazumoto
    Inaba, Hajime
    Okubo, Sho
    Akamatsu, Daisuke
    Yasuda, Masami
    Onae, Atsushi
    Hong, Feng-Lei
    2014 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2014, : 186 - 188
  • [26] Elimination of the PMD Related Delay Jitter in an Ultra-Stable Microwave Signal Distribution System
    Wang, Xi
    Wei, Wei
    Weng, Xiyi
    Wang, Danyang
    Wei, Jiawang
    Xie, Weilin
    Dong, Yi
    2022 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION (OFC), 2022,
  • [27] An ultra-stable referenced interrogation system in the deep ultraviolet for a mercury optical lattice clock
    Dawkins, S. T.
    Chicireanu, R.
    Petersen, M.
    Millo, J.
    Magalhaes, D. V.
    Mandache, C.
    Le Coq, Y.
    Bize, S.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 99 (1-2): : 41 - 46
  • [28] Ultra-stable tunable THz system for 6G communication based on photonics
    Eichler, Taro
    Puppe, Thomas
    Mueller, Sebastian
    Noack, Timo
    Deumer, Milan
    Nellen, Simon
    Mayzlin, Yuriy
    Riedmann, Nico
    Liebermeister, Lars
    Wilk, Rafal
    Kohlhaas, Robert
    Vieweg, Nico
    Hechtfischer, Gerd
    Keusgen, Wilhelm
    2023 53RD EUROPEAN MICROWAVE CONFERENCE, EUMC, 2023, : 460 - 463
  • [29] Ultra-stable fiber pumped CEP-stabilized dual stage OPCPA System
    Matyschok, J.
    Binhammer, T.
    Lang, T.
    Prochnow, O.
    Rausch, S.
    Rudawski, P.
    Arnold, C. L.
    L'Huillier, A.
    Morgner, U.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE AND INTERNATIONAL QUANTUM ELECTRONICS CONFERENCE (CLEO EUROPE/IQEC), 2013,
  • [30] Ultra-Stable Cavity System with Low Drift Rate for Mercury Optical Lattice Clock
    Fu Xiaohu
    Fang Su
    Zhao Ruchen
    Sun Jianfang
    Zhang Ye
    Xu Zhen
    Wang Yuzhu
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (09):