The comparative evaluation of patients' body dry weight under hemodialysis using two methods: Bioelectrical impedance analysis and conventional method

被引:0
|
作者
Alijanian, Neda [1 ]
Naini, Afsoon Emami [2 ]
Shahidi, Shahrzad [3 ]
Liaghat, Lida [1 ]
Samani, Rahil Riahi [1 ]
机构
[1] Isfahan Univ Med Sci, Dept Internal Med, Sch Med, Esfahan, Iran
[2] Isfahan Univ Med Sci, Isfahan Kidney Dis Res Ctr, Dept Nephrol, Sch Med, Esfahan, Iran
[3] Isfahan Univ Med Sci, Isfahan Kidney Dis Res Ctr, Dept Nephrol, Sch Med, Esfahan, Iran
来源
关键词
Bio impedance analysis; dry weight; hemodialysis; BIOIMPEDANCE SPECTROSCOPY; WHOLE-BODY; DIALYSIS PATIENTS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dry weight (DW) is an important concept related to patients undergoing hemodialysis. Conventional method seems to be time consuming and operator dependent. Bio impedance analysis (BIA) is a new and simple method reported to be an accurate way for estimating DW. In this study, we aimed to compare the conventional estimation of DW with measuring DW by BIA. Materials and Methods: This study involved 130 uremic patients, performed in Isfahan, Iran. DW was calculated by both conventional (CDW) and BIA (BIADW) method and results were compared based on different grouping factors including sex, underlying cause of renal failure (RF) (diabetic RF and non-diabetic RF), body mass index (BMI) status, and sessions of hemodialysis. We also calculated the difference between DWs of 2 methods (DW diff = CDW-BIADW). Results: The mean of BIADW was significantly lower than CDW (57.20 +/- 1.82 vs 59.36 +/- 1.77, P value < 0.001). After grouping cases according to the underlying cause, BMI, sex, and dialysis sessions BIADW was significantly lower than CDW. Conclusion: Based on the combination of problems with CDW measurement which are corrected by BIA, and more clinical reliability of CDW, we concluded that although conventional method is a time-consuming and operator-dependent way to assess DW, DW could be estimated by combining both of these methods by finding the mathematic correlation between these methods.
引用
收藏
页码:923 / 927
页数:5
相关论文
共 50 条
  • [31] Evaluation of body fluid status after cardiac surgery using bioelectrical impedance analysis
    Yamaguchi, H
    Yamauchi, H
    Hazama, S
    Hamamoto, H
    JOURNAL OF CARDIOVASCULAR SURGERY, 2000, 41 (04): : 559 - 566
  • [32] Evaluation of pulmonary congestion in hemodialysis patients: comparison between lung ultrasound and thoracic bioelectrical impedance analysis
    Donadio, C.
    Bozzoli, L.
    Colombini, E.
    Gargani, L.
    EUROPEAN HEART JOURNAL, 2016, 37 : 528 - 529
  • [33] Adjustment of dry weight in hemodialysis patients using bioimpedance analysis (BIA).
    Zhu, F
    Sarkar, S
    Kaitwatcharachai, C
    Brener, ZZ
    Morris, AT
    Greenwood, R
    Gotch, F
    Kaufman, AM
    Levin, NW
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 235A - 235A
  • [34] Reliability of Bioelectrical Impedance Analysis in the Evaluation of the Nutritional Status of Hemodialysis Patients - A Comparison With Mini Nutritional Assessment
    Erdogan, E.
    Tutal, E.
    Uyar, M. E.
    Bal, Z.
    Demirci, B. G.
    Sayin, B.
    Sezer, S.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (10) : 3485 - 3488
  • [35] Agreement between vector analysis and body composition measurements by four types of bioelectrical impedance technology in hemodialysis patients
    Espinosa-Cuevas, Angeles
    Ch-Duran, Larisa-Ximena
    Atilano-Carsi, Ximena
    Gonzalez-Ortiz, Ailema
    Ramos-Acevedo, Samuel
    Lopez-Cisneros, Sonia
    Correa-Rotter, Ricardo
    Vanessa Miranda-Alatriste, Paola
    NUTRICION HOSPITALARIA, 2022, 39 (05) : 1047 - 1057
  • [36] COMPARISON OF BODY COMPOSITION MEASUREMENTS IN PATIENTS WITH CHRONIC KIDNEY DISEASE RECEIVING MAINTENANCE HEMODIALYSIS USING BIOELECTRICAL IMPEDANCE ANALYSIS AND ANTHROPOMETRIC EQUATIONS
    Kratovil, Ashley
    Brody, Rebecca
    Sackey, Joachim
    Byham-Gray, Laura
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2023, 81 (04) : S113 - S114
  • [37] DRY-WEIGHT ASSESSMENT AMONG HEMODIALYSIS PATIENTS USING BODY COMPOSITION MONITOR
    Khan, A.
    Khan, A. H.
    Adnan, A. S.
    Sulaiman, S. A.
    Khan, I
    VALUE IN HEALTH, 2017, 20 (09) : A864 - A864
  • [38] Correlation between skinfold thickness and bioelectrical impedance analysis for the evaluation of body composition in patients on dialysis
    Laura Flores-Garcia, Ana
    Alicia Sanchez-Ramirez, Carmen
    Alberto Newton-Sanchez, Oscar
    Rojas-Larios, Fabian
    NUTRICION HOSPITALARIA, 2018, 35 (01) : 117 - 122
  • [39] BIOELECTRICAL IMPEDANCE ANALYSIS FOR BODY-COMPOSITION - CLINICAL-EVALUATION IN GENERAL SURGICAL PATIENTS
    SCHROEDER, D
    CHRISTIE, PM
    HILL, GL
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1990, 14 (02) : 129 - 133
  • [40] Body Composition Evaluation of Elementary School Students Using Bioelectrical Impedance Analysis in South Korea
    Cho, Chaeeun
    Jeon, Kyoungkyu
    Lee, Sewon
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2023, 52 (02) : 449 - 450