Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images

被引:26
|
作者
Li, Ruijiang [1 ]
Mok, Edward [1 ]
Chang, Daniel T. [1 ]
Daly, Megan [1 ]
Loo, Billy W., Jr. [1 ]
Diehn, Maximilian [1 ]
Quynh-Thu Le [1 ]
Koong, Albert [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
BODY RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; RADIOTHERAPY; LOCALIZATION; FEASIBILITY; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.ijrobp.2012.03.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To verify the geometric accuracy of gated RapidArc treatment using kV images acquired during dose delivery. Methods and Materials: Twenty patients were treated using the gated RapidArc technique with a Varian TrueBeam STx linear accelerator. One to 7 metallic fiducial markers were implanted inside or near the tumor target before treatment simulation. For patient setup and treatment verification purposes, the internal target volume (ITV) was created, corresponding to each implanted marker. The gating signal was generated from the Real-time Position Management (RPM) system. At the beginning of each fraction, individualized respiratory gating amplitude thresholds were set based on fluoroscopic image guidance. During the treatment, we acquired kV images immediately before MV beam-on at every breathing cycle, using the on-board imaging system. After the treatment, all implanted markers were detected, and their 3-dimensional (3D) positions in the patient were estimated using software developed in-house. The distance from the marker to the corresponding ITV was calculated for each patient by averaging over all markers and all fractions. Results: The average 3D distance between the markers and their ITVs was 0.8 +/- 0.5 mm (range, 0-1.7 mm) and was 2.1 +/- 1.2 mm at the 95th percentile (range, 0-3.8 mm). On average, a left-right margin of 0.6 mm, an anterior-posterior margin of 0.8 mm, and a superior-inferior margin of 1.5 mm is required to account for 95% of the intrafraction uncertainty in RPM-based RapidArc gating. Conclusion: To our knowledge, this is the first clinical report of intrafraction verification of respiration-gated RapidArc treatment in stereotactic ablative radiation therapy. For some patients, the markers deviated significantly from the ITV by more than 2 mm at the beginning of the MV beam-on. This emphasizes the need for gating techniques with beam-on/-off controlled directly by the actual position of the tumor target instead of external surrogates such as RPM. (C) 2012 Elsevier Inc.
引用
收藏
页码:E709 / E715
页数:7
相关论文
共 50 条
  • [31] X-ray Imaging Using an Electron Beam
    Neo, Yoichiro
    Suzuki, Ryuji
    Aoki, Toru
    Mmimura, Hidenori
    IDW/AD '12: PROCEEDINGS OF THE INTERNATIONAL DISPLAY WORKSHOPS, PT 3, 2012, 19 : 1773 - 1776
  • [32] Parallel-beam X-ray diffractometry using X-ray guide tubes
    Yamanoi, T
    Nakazawa, H
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2000, 33 : 389 - 391
  • [33] Accuracy of Kilovoltage X-Ray Beam Dosimetry Using a 0.6 Cc Ionization Chamber with An Absorbed Dose to Water Calibration Factor
    Uchida, Y.
    Tachibana, H.
    Kogure, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 3121 - 3121
  • [34] Segmenting root systems in X-ray computed tomography images using level sets
    Tabb, Amy
    Duncan, Keith E.
    Topp, Christopher N.
    2018 IEEE WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV 2018), 2018, : 586 - 595
  • [35] Measurement of backscatter factor for kilovoltage x-ray beam using ionization chamber and Gafchromic XR-QA2 film
    Ab Shukor, N. S.
    Asri, N. H. Mohd
    Jaafar, S. M. F. Syed
    Rosnan, M. S.
    Aziz, S. A. Abdul
    INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [36] Use of calculations to validate beam quality and relative dose measurements for a kilovoltage X-ray therapy unit
    B. J. Healy
    R. F. Hill
    Physical and Engineering Sciences in Medicine, 2022, 45 : 537 - 546
  • [37] Characterization of novel water-equivalent PRESAGE® dosimeters for megavoltage and kilovoltage x-ray beam dosimetry
    Alqathami, Mamdooh
    Blencowe, Anton
    Geso, Moshi
    Ibbott, Geoffrey
    RADIATION MEASUREMENTS, 2015, 74 : 12 - 19
  • [38] Improvement of kilovoltage beam output with a transmission x-ray target: radiological optimization and cooling system design
    Acuna-Gomez, O. L.
    Garnica-Garza, H. M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02):
  • [39] Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06): : 1595 - 1615
  • [40] Markerless Tumor Tracking during Lung Radiotherapy Using Intrafraction X-Ray Imaging
    Shieh, Chun-Chien
    Caillet, Vincent
    Dunbar, Michelle
    Keall, Paul
    Hardcastle, Nicholas
    Booth, Jeremy
    Huang, Chen-Yu
    Haddad, Carol
    Eade, Thomas
    Feain, Ilana
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S415 - S416