Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images

被引:26
|
作者
Li, Ruijiang [1 ]
Mok, Edward [1 ]
Chang, Daniel T. [1 ]
Daly, Megan [1 ]
Loo, Billy W., Jr. [1 ]
Diehn, Maximilian [1 ]
Quynh-Thu Le [1 ]
Koong, Albert [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
BODY RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; RADIOTHERAPY; LOCALIZATION; FEASIBILITY; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.ijrobp.2012.03.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To verify the geometric accuracy of gated RapidArc treatment using kV images acquired during dose delivery. Methods and Materials: Twenty patients were treated using the gated RapidArc technique with a Varian TrueBeam STx linear accelerator. One to 7 metallic fiducial markers were implanted inside or near the tumor target before treatment simulation. For patient setup and treatment verification purposes, the internal target volume (ITV) was created, corresponding to each implanted marker. The gating signal was generated from the Real-time Position Management (RPM) system. At the beginning of each fraction, individualized respiratory gating amplitude thresholds were set based on fluoroscopic image guidance. During the treatment, we acquired kV images immediately before MV beam-on at every breathing cycle, using the on-board imaging system. After the treatment, all implanted markers were detected, and their 3-dimensional (3D) positions in the patient were estimated using software developed in-house. The distance from the marker to the corresponding ITV was calculated for each patient by averaging over all markers and all fractions. Results: The average 3D distance between the markers and their ITVs was 0.8 +/- 0.5 mm (range, 0-1.7 mm) and was 2.1 +/- 1.2 mm at the 95th percentile (range, 0-3.8 mm). On average, a left-right margin of 0.6 mm, an anterior-posterior margin of 0.8 mm, and a superior-inferior margin of 1.5 mm is required to account for 95% of the intrafraction uncertainty in RPM-based RapidArc gating. Conclusion: To our knowledge, this is the first clinical report of intrafraction verification of respiration-gated RapidArc treatment in stereotactic ablative radiation therapy. For some patients, the markers deviated significantly from the ITV by more than 2 mm at the beginning of the MV beam-on. This emphasizes the need for gating techniques with beam-on/-off controlled directly by the actual position of the tumor target instead of external surrogates such as RPM. (C) 2012 Elsevier Inc.
引用
收藏
页码:E709 / E715
页数:7
相关论文
共 50 条
  • [11] Evaluation of gantry angle during respiratory-gated VMAT using triggered kilovoltage x-ray image
    Miyasaka, Ryohei
    Saitoh, Hidetoshi
    Kawachi, Toru
    Katayose, Tetsurou
    Cho, SangYong
    Yamauchi, Ryohei
    Hara, Ryusuke
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 98 - 104
  • [12] A study on the suitability of the PTW microDiamond detector for kilovoltage x-ray beam dosimetry
    Damodar, Joshita
    Odgers, David
    Pope, Dane
    Hill, Robin
    APPLIED RADIATION AND ISOTOPES, 2018, 135 : 104 - 109
  • [13] Intrafraction Position Management Post-Cone Beam CT Using Stereoscopic X-Ray Verification for Stereotactic Body Radiation Therapy Lung Treatment
    Abing, C.
    Wochos, J.
    Driscoll, C.
    Conway, P.
    Gold, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S835 - S835
  • [14] Image guided radiotherapy using a mobile kilovoltage X-ray device
    Solberg, TD
    Chow, PE
    Sorensen, S
    Wink, N
    Mitschke, MM
    Ritter, D
    Agazaryan, N
    Lee, SP
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S615 - S615
  • [15] Kilovoltage X-ray beam quality effect on the relative response of alanine pellet dosemeters
    Hjorringgaard, Jakob G.
    Ankjaergaard, Christina
    Miller, Arne
    Andersen, Claus E.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (14) : 1605 - 1610
  • [16] Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy
    Moore, C. J.
    Amer, A.
    Marchant, T.
    Sykes, J. R.
    Davies, J.
    Stratford, J.
    McCarthy, C.
    MacBain, C.
    Henry, A.
    Price, P.
    Williams, P. C.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 : S66 - S78
  • [17] Measurement of patient imaging dose for real-time kilovoltage x-ray intrafraction tumour position monitoring in prostate patients
    Crocker, James K.
    Ng, Jin Aun
    Keall, Paul J.
    Booth, Jeremy T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (10): : 2969 - 2980
  • [18] MArkerless image Guidance using Intrafraction Kilovoltage x-ray imaging (MAGIK): study protocol for a phase I interventional study for lung cancer radiotherapy
    Mueller, Marco
    Booth, Jeremy
    Briggs, Adam
    Jayamanne, Dasantha
    Panettieri, Vanessa
    Senthi, Sashendra
    Shieh, Chun-Chien
    Keall, Paul
    BMJ OPEN, 2022, 12 (01):
  • [19] Retrieving images from tarnished daguerreotypes using X-ray fluorescence imaging with an X-ray micro beam with tunable energy
    Sham, Tsun-Kong
    Finfrock, Y. Zou
    Xiao, Qunfeng
    Bassnett, Sarah
    Feng, Renfei
    JOURNAL OF CULTURAL HERITAGE, 2024, 67 : 53 - 61
  • [20] A comparison of beam characteristics for gated and nongated clinical x-ray beams
    Ramsey, CR
    Cordrey, IL
    Oliver, AL
    MEDICAL PHYSICS, 1999, 26 (10) : 2086 - 2091