Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry

被引:43
|
作者
Casiraghi, Francesca [1 ,2 ,3 ]
Lertwattanarak, Raweewan [1 ,4 ]
Luzi, Livio [2 ,3 ]
Chavez, Alberto O. [1 ]
Davalli, Alberto M. [5 ]
Naegelin, Terry [6 ]
Comuzzie, Anthony G. [6 ,7 ]
Frost, Patricia [6 ]
Musi, Nicolas [1 ,4 ]
Folli, Franco [1 ,7 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Med, Div Diabet, San Antonio, TX 78229 USA
[2] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
[3] IRCCS Policlin San Donato Hosp, Metab Res Ctr, Milan, Italy
[4] Texas Diabet Inst, San Antonio, TX USA
[5] Univ Milan, Osped San Raffaele, Dept Internal Med, I-20127 Milan, Italy
[6] Southwest Natl Primate Res Ctr, San Antonio, TX USA
[7] Texas Biomed Res Inst, Dept Genet, San Antonio, TX USA
来源
PLOS ONE | 2013年 / 8卷 / 09期
基金
美国国家卫生研究院;
关键词
PHYSICAL-ACTIVITY; MULTISENSOR ARMBAND; ACTIVITY MONITORS; DETERMINANTS; ACCURACY; VALIDITY; DEVICE; COST;
D O I
10.1371/journal.pone.0073651
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. Methods: We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. Results: In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1 +/- 0.3 SWAs, 1 +/- 0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5 +/- 1.9 SWA ARM, 4.5 +/- 1.5 SWA BACK and 5.4 +/- 2.1 IC kcal/min). In the non- human primate (baboons) experiment SWA estimated a TEE of 0.54 +/- 0.009 kcal/min during free living and a REE of 0.82 +/- 0.06 kcal/min. Conclusion: SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with "gold standard'', IC, in humans.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Poor agreement between a portable armband and indirect calorimetry in the assessment of resting energy expenditure
    Cynober, Luc
    CLINICAL NUTRITION, 2008, 27 (02) : 311 - 312
  • [32] COMPARISON OF TOTAL ENERGY EXPENDITURE MEASUREMENTS FROM ARMBAND AND INDIRECT CALORIMETRY ESTIMATIONS IN A SAMPLE OF DIALYSIS PATIENTS
    Chan, M.
    Avesani, C.
    Carrero, J.
    Faxen-Irving, G.
    Stenvinkel, P.
    Lindholm, B.
    Heimburger, O.
    NEPHROLOGY, 2008, 13 : A147 - A147
  • [33] Accuracy of the SenseWear Armband for Energy Expenditure Estimation During Interactive Video Exergaming or Treadmill Exercise in Type 2 Diabetic Adults
    Hsia, Stanley H.
    Magliano, Lynne A.
    Sanchez, Humberto
    Storer, Thomas W.
    DIABETES, 2012, 61 : A184 - A184
  • [34] Accuracy Of Sensewear® Pro Armband In Estimating Energy Expenditure During Steady-state And Non-steady-state Physical Activity
    Bhammar, Dharini M.
    Sawyer, Brandon J.
    Angadi, Siddhartha A.
    Gaesser, Glenn A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 646 - 647
  • [35] Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry
    Sundstrom, Martin
    Mehrabi, Mahboubeh
    Tjader, Inga
    Rooyackers, Olav
    Hammarqvist, Folke
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2017, 41 (06) : 976 - 980
  • [36] ENERGY EXPENDITURE OF TYPE-SPECIFIC SEDENTARY BEHAVIORS ESTIMATED USING SENSEWEAR MINI ARMBAND: A METABOLIC CHAMBER VALIDATION STUDY AMONG ADOLESCENTS
    Jin, Jing
    Zhuang, Jie
    Zhu, Zheng
    Wang, Siya
    Chen, Peijie
    Zhu, Weimo
    KINESIOLOGY, 2018, 50 (01) : 52 - 56
  • [37] Measuring energy expenditure in cardiac patients using the Body Media™ Armband versus indirect calorimetry -: A validation study
    Cole, PJ
    Lemura, LM
    Klinger, TA
    Strohecker, K
    McConnell, TR
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2004, 44 (03): : 262 - 271
  • [38] Evaluation of total energy expenditure in adult, overweight and free-living subjects. A comparison between two methods: Factorial Method vs SenseWear Armband "Metabolic Holter"
    Giobbi, F.
    CLINICA TERAPEUTICA, 2008, 159 (06): : 405 - 407
  • [39] Validity of the ActiGraph GT3X+and BodyMedia SenseWear Armband to estimate energy expenditure during physical activity and sport
    Gastin, Paul B.
    Cayzer, Cassy
    Dwyer, Dan
    Robertson, Sam
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2018, 21 (03) : 291 - 295
  • [40] Validation of Physical Activity Monitors in Individuals with Diabetes: Energy Expenditure Estimation by the Multisensor SenseWear Armband Pro3 and the Step Counter Omron HJ-720 Against Indirect Calorimetry During Walking
    Machac, Stanislav
    Prochazka, Michal
    Radvansky, Jiri
    Slaby, Krystof
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (05) : 413 - 418