Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry

被引:43
|
作者
Casiraghi, Francesca [1 ,2 ,3 ]
Lertwattanarak, Raweewan [1 ,4 ]
Luzi, Livio [2 ,3 ]
Chavez, Alberto O. [1 ]
Davalli, Alberto M. [5 ]
Naegelin, Terry [6 ]
Comuzzie, Anthony G. [6 ,7 ]
Frost, Patricia [6 ]
Musi, Nicolas [1 ,4 ]
Folli, Franco [1 ,7 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Med, Div Diabet, San Antonio, TX 78229 USA
[2] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
[3] IRCCS Policlin San Donato Hosp, Metab Res Ctr, Milan, Italy
[4] Texas Diabet Inst, San Antonio, TX USA
[5] Univ Milan, Osped San Raffaele, Dept Internal Med, I-20127 Milan, Italy
[6] Southwest Natl Primate Res Ctr, San Antonio, TX USA
[7] Texas Biomed Res Inst, Dept Genet, San Antonio, TX USA
来源
PLOS ONE | 2013年 / 8卷 / 09期
基金
美国国家卫生研究院;
关键词
PHYSICAL-ACTIVITY; MULTISENSOR ARMBAND; ACTIVITY MONITORS; DETERMINANTS; ACCURACY; VALIDITY; DEVICE; COST;
D O I
10.1371/journal.pone.0073651
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. Methods: We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. Results: In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1 +/- 0.3 SWAs, 1 +/- 0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5 +/- 1.9 SWA ARM, 4.5 +/- 1.5 SWA BACK and 5.4 +/- 2.1 IC kcal/min). In the non- human primate (baboons) experiment SWA estimated a TEE of 0.54 +/- 0.009 kcal/min during free living and a REE of 0.82 +/- 0.06 kcal/min. Conclusion: SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with "gold standard'', IC, in humans.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Energy Expenditure From Actireg And Sensewear Armband Compared To Doubly Labeled Water In Adolescents
    Arvidsson, Daniel
    Slinde, Frode
    Hulthen, Lena
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S206 - S206
  • [22] Validity of SenseWear® Armband v5.2 and v2.2 for estimating energy expenditure
    Bhammar, Dharini M.
    Sawyer, Brandon J.
    Tucker, Wesley J.
    Lee, Jung-Min
    Gaesser, Glenn A.
    JOURNAL OF SPORTS SCIENCES, 2016, 34 (19) : 1830 - 1838
  • [23] Accuracy of SenseWear Pro2 Armband to Predict Resting Energy Expenditure in Childhood Obesity
    Predieri, Barbara
    Bruzzi, Patrizia
    Lami, Francesca
    Vellani, Giulia
    Malavolti, Marcella
    Battistini, Nino C.
    Iughetti, Lorenzo
    OBESITY, 2013, 21 (12) : 2465 - 2470
  • [24] Accuracy Of The Sensewear Armband Mini-fly For Estimating Energy Expenditure Across Bmi Categories
    Forseth, Bethany M.
    Bassett, David R.
    Crouter, Scott E.
    Coe, Dawn P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 14 - 14
  • [25] Validity of the SenseWear Armband to Assess Energy Expenditure During Intermittent Exercise and Recovery in Rugby Union Players
    Zanetti, Sara
    Pumpa, Kate L.
    Wheeler, Keane W.
    Pyne, David B.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (04) : 1090 - 1095
  • [26] Validity of SenseWear Armband to Estimate Energy Expenditure During Activities of Daily Living In Rheumatoid Arthritis.
    Tierney, Marie
    Fraser, Alexander D.
    Kennedy, Norelee M.
    ARTHRITIS AND RHEUMATISM, 2011, 63 (10): : S941 - S942
  • [27] Monitoring Energy Expenditure Using a Multi-Sensor Device Applications and Limitations of the SenseWear Armband in Athletic Populations
    Koehler, Karsten
    Drenowatz, Clemens
    FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [28] Ambulatory monitoring of energy expenditure and physical activity levels using the SenseWear Armband™ System in Parkinson's disease
    de la Cruz, C. Rodriguez
    Bury, T.
    Le Scanff, S.
    Robert, F.
    Maquet, D.
    Croisier, J. -L.
    Garraux, G.
    MOVEMENT DISORDERS, 2010, 25 (07) : S355 - S356
  • [29] Validation of SenseWear Armband and ActiHeart monitors for assessments of daily energy expenditure in free-living women with chronic obstructive pulmonary disease
    Farooqi, Nighat
    Slinde, Frode
    Haglin, Lena
    Sandstrom, Thomas
    PHYSIOLOGICAL REPORTS, 2013, 1 (06): : 1 - 12
  • [30] Evaluation of a multisensor armband in estimating energy expenditure in obese individuals
    Papazoglou, Dimitrios
    Augello, Giovanni
    Tagliaferri, Mariantonella
    Savia, Giulio
    Marzullo, Paolo
    Maltezos, Efstratios
    Liuzzi, Antonio