Impact of Continuous and Pulsatile-Flow Left Ventricular Assist Devices on Post-Transplant Rejection

被引:1
|
作者
Urban, M. [1 ]
Szarszoi, O. [1 ]
Pirk, J. [1 ]
Riha, H. [1 ]
Netuka, I. [1 ]
机构
[1] Inst Clin & Expt Med, Prague, Czech Republic
来源
关键词
D O I
10.1016/j.healun.2013.01.721
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
763
引用
收藏
页码:S275 / S275
页数:1
相关论文
共 50 条
  • [21] Ventricular assist devices as bridge to heart transplantation: impact on post-transplant infections
    Hequet, Delphine
    Kralidis, Georg
    Carrel, Thierry
    Cusini, Alexia
    Garzoni, Christian
    Hullin, Roger
    Meylan, Pascal R.
    Mohacsi, Paul
    Mueller, Nicolas J.
    Ruschitzka, Frank
    Tozzi, Piergiorgio
    van Delden, Christian
    Weisser, Maja
    Wilhelm, Markus J.
    Pascual, Manuel
    Manuel, Oriol
    BMC INFECTIOUS DISEASES, 2016, 16
  • [22] Do Posttransplant Outcomes Differ in Heart Transplant Recipients Bridged With Continuous and Pulsatile Flow Left Ventricular Assist Devices?
    Hong, Kimberly N.
    Iribarne, Alexander
    Yang, Jonathan
    Ramlawi, Basel
    Takayama, Hiroo
    Naka, Yoshifumi
    Russo, Mark J.
    ANNALS OF THORACIC SURGERY, 2011, 91 (06): : 1899 - 1906
  • [23] Differential Impact on Post-transplant Outcomes between HeartMate XVE and HeartMate II Left Ventricular Assist Devices
    Ventura, P. A.
    Reid, B. B.
    Horne, B. D.
    Mason, N. O.
    Stoker, S.
    Alharethi, R.
    Budge, D.
    Rasmusson, B.
    Doty, J.
    Clayson, S. E.
    Kfoury, A. G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S99 - S99
  • [24] The incidence of right ventricular dysfunction is similar in pulsatile and continuous-flow left ventricular assist devices
    Feller, Erika D.
    Sorensen, Erik N.
    Johnson, Frances L.
    Gottlieb, Stephen S.
    Haddad, Michel
    Pierson, Richard N.
    Griffith, Bartley P.
    JOURNAL OF CARDIAC FAILURE, 2006, 12 (06) : S49 - S49
  • [25] SYNCHRONIZED PULSATILE FLOW WITH A CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE
    Rutten, M. C. M.
    Tuzun, E.
    de Vosse, F. N. van
    de Mol, B. A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 449 - 449
  • [26] Post-transplant Survival is Not Diminished in Heart Transplant Recipients Bridged With Implantable Left Ventricular Assist Devices
    Russo, Mark
    Hong, Kimberly N.
    Davies, Ryan
    Williams, Mathew
    Argenziano, Michael
    Gelijns, Annetine
    Naka, Yoshifumi
    CIRCULATION, 2009, 120 (18) : S798 - S798
  • [27] Late right heart failure during support with continuous-flow left ventricular assist devices adversely affects post-transplant outcome
    Takeda, Koji
    Takayama, Hiroo
    Colombo, Paolo C.
    Jorde, Ulrich P.
    Yuzefpolskaya, Melana
    Fukuhara, Shinichi
    Mancini, Donna M.
    Naka, Yoshifumi
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (05): : 667 - 674
  • [28] Allograft Rejection in Patients Supported With Continuous-Flow Left Ventricular Assist Devices
    Healy, Aaron H.
    Mason, Nathan O.
    Hammond, M. Elizabeth
    Reid, Bruce B.
    Clayson, Stephen E.
    Drakos, Stavros G.
    Kfoury, Abdallah G.
    Patel, Amit N.
    Bull, David A.
    Budge, Deborah
    Alharethi, Rami A.
    Bader, Feras M.
    Gilbert, Edward M.
    Stehlik, Josef
    Selzman, Craig H.
    ANNALS OF THORACIC SURGERY, 2011, 92 (05): : 1601 - 1607
  • [29] Continuous Flow and Pulsatile Left Ventricular Assist Devices Associated With Similar Rates of Gastrointestinal Bleeding
    Menard-Katcher, Paul
    Brisco, Meredith A.
    Rame, J. Eduardo
    Metz, David C.
    GASTROENTEROLOGY, 2011, 140 (05) : S396 - S396
  • [30] Renal flow function after implantation of continuous versus pulsatile left ventricular assist devices
    Sandner, Sigrid E.
    Zimpfer, Daniel
    Zrunek, Philipp
    Dunkler, Daniela
    Schima, Heinrich
    Rajek, Angela
    Grimm, Michael
    Wolner, Ernst
    Wieselthaler, Georg M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (05): : 469 - 473