Capacitive Heart-Rate Sensing on Touch Screen Panel with Laterally Interspaced Electrodes

被引:4
|
作者
Kim, Junhyung [1 ]
Song, Wonho [2 ]
Jung, Sungchul [3 ]
Kim, Yuna [4 ]
Park, Wonsang [4 ]
You, Bonghyun [4 ]
Park, Kibog [1 ,2 ]
机构
[1] Ulsan Natl Inst Sci & Technol UNIST, Sch Elect & Comp Engn, Ulsan 44919, South Korea
[2] Ulsan Natl Inst Sci & Technol UNIST, Dept Phys, Ulsan 44919, South Korea
[3] SK Hynix, Icheon Si 17336, Gyeonggi Do, South Korea
[4] Samsung Display Giheung Campus, Yongin 17113, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
heart-rate sensing; capacitive touch screen panel; laterally-interspaced electrodes; ulnar artery; effective dielectric constant; fast fourier transformation; biomedical monitoring; multi-functional sensor;
D O I
10.3390/s20143986
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is demonstrated that the heart-rate can be sensed capacitively on a touch screen panel (TSP) together with touch signals. The existing heart-rate sensing systems measure blood pulses by tracing the amount of light reflected from blood vessels during a number of cardiac cycles. This type of sensing system requires a considerable amount of power and space to be implemented in multi-functional mobile devices such as smart phones. It is found that the variation of the effective dielectric constant of finger stemming from the difference of systolic and diastolic blood flows can be measured with laterally interspaced top electrodes of TSP. The spacing between a pair of non-adjacent top electrodes turns out to be wide enough to distinguish heart-rate signals from noises. With the aid of fast Fourier transform, the heart-rate can be extracted reliably, which matches with the one obtained by actually counting heart beats on the wrist.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [31] RootCap: Touch Detection on Multi-electrodes using Single-line Connected Capacitive Sensing
    Tsuruta, Masaya
    Nakamae, Shuta
    Shizuki, Buntarou
    PROCEEDINGS OF THE 2016 ACM INTERNATIONAL CONFERENCE ON INTERACTIVE SURFACES AND SPACES, (ISS 2016), 2016, : 23 - 32
  • [32] A Contact-Based Data Communication Technique Using Capacitive Touch Screen Panel and Support Vector Machine Classifier
    Seol, Ki-Hyuk
    Park, Seungjun
    Nam, Hyoungsik
    IEEE ACCESS, 2019, 7 : 178596 - 178604
  • [33] Mutual Capacitive Sensing Touch Screen Controller for Ultrathin Display with Extended Signal Passband Using Negative Capacitance
    Lee, Chang-Ju
    Park, Jong Kang
    Piao, Canxing
    Seo, Han-Eol
    Choi, Jaehyuk
    Chun, Jung-Hoon
    SENSORS, 2018, 18 (11)
  • [34] HEART RATE DETECTION FROM IMPEDANCE PLETHYSMOGRAPHY BASED ON CONCEALED CAPACITIVE ELECTRODES
    Luna-Lozano, Pablo S.
    Pallas-Areny, Ramon
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1701 - 1706
  • [35] High-performance mutual-capacitive touch screen using double-layered metal-mesh electrodes with separated floating electrodes
    Nojiri, Isao
    Ono, Takeshi
    Agari, Masafumi
    Mori, Seiichiro
    Imamura, Takuji
    Miyayama, Takashi
    Nakamura, Tatsuya
    Nakagawa, Naoki
    Digest of Technical Papers - SID International Symposium, 2014, 45 (01): : 544 - 547
  • [36] A Touch Prediction and Window Sensing Strategy for Low-Power and Low-Cost Capacitive Multitouch Screen Systems
    Li, Bo
    Wei, Tingcun
    Wei, Xiaomin
    Wang, Jia
    Liu, Wei
    Zheng, Ran
    JOURNAL OF DISPLAY TECHNOLOGY, 2016, 12 (06): : 646 - 657
  • [37] IMPROVED HEART-RATE AND EXERCISE PERFORMANCE WITH AN ACTIVITY SENSING PACEMAKER - A MULTICENTER STUDY
    CHEVALIER, P
    LINDEMANS, F
    MURTAUGH, R
    RANKIN, I
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (05): : 775 - 775
  • [38] Symmetric Signal Reconstruction and Frequency-Division Differential Driving for High Rate Touch Screen Sensing
    Choi, GyeongSeop
    Mohamed, M. G. A.
    Kim, HyungWon
    JOURNAL OF DISPLAY TECHNOLOGY, 2016, 12 (11): : 1423 - 1432
  • [39] CAN ACTIVITY SENSING RATE RESPONSIVE PACEMAKERS MATCH THE NORMAL HEART-RATE REQUIREMENTS OF RECREATIONAL SWIMMING
    WEBB, SC
    LEWIS, LM
    MORRISTHURGOOD, JA
    CRICK, J
    MASERI, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 514 - 514
  • [40] A 3.9kHz-Frame-Rate Capacitive Touch System with Pressure/Tilt Angle Expressions of Active Stylus Using Multiple-Frequency Driving Method for 65" 104x64 Touch Screen Panel
    An, Jae-Sung
    Han, Sang-Hyun
    Kim, Ju Eon
    Yoon, Dong-Hyun
    Kim, Young-Hwan
    Hong, Han-Hee
    Ye, Jae-Hun
    Jung, Sung-Jin
    Lee, Seung-Hwan
    Jeong, Ji-Yong
    Baek, Kwang-Hyun
    Hong, Seong-Kwan
    Kwon, Oh-Kyong
    2017 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE (ISSCC), 2017, : 168 - 168