Small Conductive Particle Detection with a Microwave Resonant Cavity

被引:2
|
作者
Ikeda, Makoto [1 ]
Mase, Atsushi [2 ,3 ]
Uchino, Kiichiro [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn Sci, Fukuoka 812, Japan
[2] Kyushu Univ, Adv Sci & Technol Ctr Cooperat Res, Fukuoka 812, Japan
[3] Kyushu Univ, Art Sci & Technol Ctr Cooperat Res, Fukuoka 812, Japan
关键词
conductive particle detection; RF cavity;
D O I
10.1002/eej.22490
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The recent miniaturization and increased complexity of electrical devices have increased the influence of impurities on device performance, especially the influence of small conductive particles with a size on the order of micrometers. Therefore, the inspection of devices during the manufacturing process has become important. In this study, changes in the resonance properties of a microwave cavity were used to detect a metal particle. The decrease in the resonant frequency for a 100-mu m stainless steel sphere was about 0.1 MHz, which was less than 1ppm of the resonant frequency used. This frequency change is too small to detect directly in the output of a particle detector. Transmission measurements (the scattering parameter S21) at a frequency that was a few megahertz higher than the resonant frequency where the S21 changes sharply were used to magnify signal changes resulting from the introduction of a small conductive particle. A resonant frequency of 13.3 GHz and a frequency 3 MHz higher were chosen for obtaining measurements in the present study. By applying a filtering technique, it was shown that the minimum detectable sphere size is around 50 mu m. This sensitivity was experimentally shown to be uneven along the long axis of the cavity. The unevenness was related to the electrical field strength of the standing wave at the resonant frequency. For practical industrial inspection of devices, multiple frequencies should be employed in view of the present discussion. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [41] PLASMA PARAMETERS USING PERTURBATION OF A RESONANT MICROWAVE CAVITY AS A PROBE
    FREEMAN, RH
    ROBERTS, JA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (11): : 1247 - &
  • [42] HIGH-EFFICIENCY RESONANT CAVITY MICROWAVE OPTICAL MODULATOR
    TRAN, NH
    GALLAGHER, TF
    WATJEN, JP
    JANIK, GR
    CARLISLE, CB
    APPLIED OPTICS, 1985, 24 (24): : 4282 - 4284
  • [43] Effective Application of Microwave Resonant Cavity System to Flow Chemistry
    Odajima, Hiromichi
    Okamoto, Tadashi
    CHEMICAL RECORD, 2019, 19 (01): : 204 - 211
  • [44] Temperature distribution in a flowing fluid heated in a microwave resonant cavity
    Thomas, JR
    Nelson, EM
    Kares, RJ
    Stringfield, RM
    MICROWAVE PROCESSING OF MATERIALS V, 1996, 430 : 565 - 569
  • [45] Method for air humidity measurement based on microwave resonant cavity
    Zhang, Shu-E
    Zhao, Jun-Chao
    Li, Yong-Qian
    Xiong, Hua
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (02): : 27 - 32
  • [46] INVESTIGATION OF STABILIZED RESONANT-CAVITY MICROWAVE PLASMAS FOR PROPULSION
    BALAAM, P
    MICCI, MM
    JOURNAL OF PROPULSION AND POWER, 1995, 11 (05) : 1021 - 1027
  • [47] MICROWAVE SPECTRA AND ZEEMAN EFFECT IN A RESONANT CAVITY ABSORPTION CELL
    JEN, CK
    PHYSICAL REVIEW, 1947, 72 (10): : 986 - 986
  • [48] Numerical enhancements of the microwave resonant cavity method for plasma diagnostics
    Faltynek, J.
    Kudrle, V
    Tesar, J.
    Volfova, M.
    Talsky, A.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2019, 28 (10):
  • [49] RESONANT FREQUENCIES AND FIELDS OF A MICROWAVE CAVITY CONTAINING A MAGNETOPLASMA DIELECTRIC
    KENT, G
    THOMAS, D
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1500 - &
  • [50] A simple method for permittivity measuring using microwave resonant cavity
    Milovanovic, B
    Ivkovic, S
    Tasic, V
    MIKON-98: 12TH INTERNATIONAL CONFERENCE ON MICROWAVES & RADAR, VOLS 1-4, 1998, : 705 - 709