Small Conductive Particle Detection with a Microwave Resonant Cavity

被引:2
|
作者
Ikeda, Makoto [1 ]
Mase, Atsushi [2 ,3 ]
Uchino, Kiichiro [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn Sci, Fukuoka 812, Japan
[2] Kyushu Univ, Adv Sci & Technol Ctr Cooperat Res, Fukuoka 812, Japan
[3] Kyushu Univ, Art Sci & Technol Ctr Cooperat Res, Fukuoka 812, Japan
关键词
conductive particle detection; RF cavity;
D O I
10.1002/eej.22490
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The recent miniaturization and increased complexity of electrical devices have increased the influence of impurities on device performance, especially the influence of small conductive particles with a size on the order of micrometers. Therefore, the inspection of devices during the manufacturing process has become important. In this study, changes in the resonance properties of a microwave cavity were used to detect a metal particle. The decrease in the resonant frequency for a 100-mu m stainless steel sphere was about 0.1 MHz, which was less than 1ppm of the resonant frequency used. This frequency change is too small to detect directly in the output of a particle detector. Transmission measurements (the scattering parameter S21) at a frequency that was a few megahertz higher than the resonant frequency where the S21 changes sharply were used to magnify signal changes resulting from the introduction of a small conductive particle. A resonant frequency of 13.3 GHz and a frequency 3 MHz higher were chosen for obtaining measurements in the present study. By applying a filtering technique, it was shown that the minimum detectable sphere size is around 50 mu m. This sensitivity was experimentally shown to be uneven along the long axis of the cavity. The unevenness was related to the electrical field strength of the standing wave at the resonant frequency. For practical industrial inspection of devices, multiple frequencies should be employed in view of the present discussion. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [21] Replacement of Waveguides by a Resonant Cavity in a Microwave CVD Reactor
    Isoldi, Mauricio
    Ozono, Edson Moriyoshi
    Mansano, Ronaldo Domingues
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (09) : 2718 - 2721
  • [22] INTERACTION OF A VIRCATOR MICROWAVE GENERATOR WITH AN ENCLOSING RESONANT CAVITY
    BENFORD, J
    PRICE, D
    SZE, H
    BROMLEY, D
    JOURNAL OF APPLIED PHYSICS, 1987, 61 (05) : 2098 - 2100
  • [23] MICROWAVE RESONANT-CAVITY-PRODUCED AIR DISCHARGES
    PASSOW, ML
    BRAKE, ML
    LOPEZ, P
    MCCOLL, WB
    REPETTI, TE
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1991, 19 (02) : 219 - 228
  • [24] MICROWAVE ION-SOURCE USING RESONANT CAVITY
    TAHARA, H
    YASUI, T
    ONOE, K
    TSUBAKISHITA, Y
    YOSHIKAWA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (3A): : 1298 - 1302
  • [25] Microwave Resonant Cavity as a Reactor for the Enzymatic Hydrolysis of Sucrose
    Casu, S.
    Fantil, A.
    Djuric, N.
    Desogus, F.
    Mazzarellal, G.
    2015 IEEE 15th Mediterranean Microwave Symposium (MMS), 2015,
  • [26] Perturbation of resonant microwave cavity by select alcohol vapors
    Prakash, V.
    Roberts, J.A.
    Journal of Microwave Power, 1986, 21 (01): : 45 - 50
  • [27] STARK-EFFECT, RESONANT CAVITY MICROWAVE SPECTROGRAPH
    VERDIER, PH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (07): : 646 - 647
  • [28] OBSERVATION OF HYSTERESIS EFFECT IN THE DETUNING OF A RESONANT MICROWAVE CAVITY
    PRAKASH, V
    ROBERTS, JA
    JOURNAL OF CHEMICAL PHYSICS, 1984, 80 (09): : 4562 - 4563
  • [29] PERTURBATION OF A RESONANT MICROWAVE CAVITY BY SELECT ALCOHOL VAPORS
    PRAKASH, V
    ROBERTS, JA
    JOURNAL OF MICROWAVE POWER AND ELECTROMAGNETIC ENERGY, 1986, 21 (01) : 45 - 50
  • [30] Resonant Cavity as Microwave Exposure System for Biological Materials
    Djuric, N.
    Bjelica, J.