Small Conductive Particle Detection with a Microwave Resonant Cavity

被引:2
|
作者
Ikeda, Makoto [1 ]
Mase, Atsushi [2 ,3 ]
Uchino, Kiichiro [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn Sci, Fukuoka 812, Japan
[2] Kyushu Univ, Adv Sci & Technol Ctr Cooperat Res, Fukuoka 812, Japan
[3] Kyushu Univ, Art Sci & Technol Ctr Cooperat Res, Fukuoka 812, Japan
关键词
conductive particle detection; RF cavity;
D O I
10.1002/eej.22490
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The recent miniaturization and increased complexity of electrical devices have increased the influence of impurities on device performance, especially the influence of small conductive particles with a size on the order of micrometers. Therefore, the inspection of devices during the manufacturing process has become important. In this study, changes in the resonance properties of a microwave cavity were used to detect a metal particle. The decrease in the resonant frequency for a 100-mu m stainless steel sphere was about 0.1 MHz, which was less than 1ppm of the resonant frequency used. This frequency change is too small to detect directly in the output of a particle detector. Transmission measurements (the scattering parameter S21) at a frequency that was a few megahertz higher than the resonant frequency where the S21 changes sharply were used to magnify signal changes resulting from the introduction of a small conductive particle. A resonant frequency of 13.3 GHz and a frequency 3 MHz higher were chosen for obtaining measurements in the present study. By applying a filtering technique, it was shown that the minimum detectable sphere size is around 50 mu m. This sensitivity was experimentally shown to be uneven along the long axis of the cavity. The unevenness was related to the electrical field strength of the standing wave at the resonant frequency. For practical industrial inspection of devices, multiple frequencies should be employed in view of the present discussion. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [3] Modeling and experimental detection of resonance frequency shift of a microwave cavity caused by a small conductive particle
    Ikeda, Makoto
    Ignatenko, Maxim
    Mase, Atsushi
    Uchino, Kiichiro
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2013, 27 (09) : 1114 - 1126
  • [4] DETECTION OF THE OPTOGALVANIC EFFECT IN FLAMES WITH A MICROWAVE RESONANT CAVITY.
    Suzuki, T.
    Fukasawa, T.
    Sekiguchi, H.
    Kasuya, T.
    Applied physics. B, Photophysics and laser chemistry, 1986, 39 (04): : 247 - 250
  • [5] Research on sliver detection based on microwave resonant cavity perturbation principle
    Shi, Shuaixing
    Li, Xinrong
    Feng, Wenqian
    Han, Penghui
    Liu, Rongfang
    JOURNAL OF THE TEXTILE INSTITUTE, 2024,
  • [6] Resonant cavity for the measurement of microwave magnetic permeability using the small perturbation theory
    Gouveia, D. X.
    Costa, L. C.
    Valente, M. A.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2008, 50 (02) : 399 - 402
  • [7] Resonant microwave cavity of amorphous ribbons
    Medina, AN
    Knobel, M
    SalemSugui, S
    Gandra, FG
    JOURNAL OF APPLIED PHYSICS, 1996, 79 (08) : 5462 - 5464
  • [8] MICROWAVE PROPERTIES OF YARNS AND TEXTILES USING A RESONANT MICROWAVE CAVITY
    KUMAR, A
    SMITH, DG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1977, 26 (02) : 95 - 98
  • [9] Microwave generation of a virtual cathode in a resonant cavity
    Seo, Y
    Choi, EH
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1997, 30 (01) : 65 - 69
  • [10] REHEATING IN HYPOTHERMIA USING A MICROWAVE RESONANT CAVITY
    BLOOR, K
    BAILLIE, HD
    BRITISH JOURNAL OF SURGERY, 1966, 53 (11) : 992 - &