Review: Influence of alloy addition and spinel coatings on Cr-based metallic interconnects of solid oxide fuel cells

被引:69
|
作者
Hassan, Muhammad Aqib [1 ]
Mamat, Othman Bin [1 ]
Mehdi, Muhammad [2 ,3 ]
机构
[1] Univ Teknol Petronas, Dept Mech Engn, Seri Iskandar 32610, Perak Darul Rid, Malaysia
[2] Korea Inst Energy Res, Hydrogen Lab, 152 Gajeong Ro, Daejeon 34129, South Korea
[3] Univ Sci & Technol, Adv Energy & Syst Engn, 217 Gajeong Ro, Daejeon 34113, South Korea
关键词
Solid oxide fuel cell; Cr-based metallic interconnects; Cr-migration; Spinel coatings; Crofer; 22; APU; SUS; 430; FERRITIC STAINLESS-STEEL; CROFER; 22; APU; AREA-SPECIFIC RESISTANCE; MN-CO-O; OXIDATION BEHAVIOR; SOFC INTERCONNECT; PROTECTIVE-COATINGS; ELECTRICAL BEHAVIOR; THERMAL-EXPANSION; COBALT SPINEL;
D O I
10.1016/j.ijhydene.2020.06.234
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Solid oxide fuel cell (SOFC) is the modern eco-friendly technology of fuel cell power generation system. It generates electricity from a redox chemical reaction without producing hazardous gases. It consists of anode, cathode and electrolyte. It is operated in the form of stack connected by interconnects to boost-up power output. The recent development of low-temperature (600 degrees C-800 degrees C) brings an opportunity to use metallic interconnects over ceramics. Cr-based metallic interconnects are one of the prominent metallic interconnects. They offer chemical inertness, thermal stability, compatible coefficient of thermal expansion and highly dense structure. However, the Cr-migration towards the cathode side is the major problem in them which adversely affect the SOFCs performance. Therefore a good oxidation resistance without sacrificing electrical conductivity is required. To resolve this issue, several alloying elements and spinel coatings have experimented. These spinel coatings are the thin solid films of Mn, Co, Cu and rare earth metals. This review concluded that the Mn-Co based spinal coating showed excellent performance in reducing the Cr migration in specially designed expensive Crofer 22 APU interconnect. However, the emerging low-cost ferritic interconnects also show their best results with Cu-Fe based spinel coating. Among them, the SUS-430 interconnect shows the equivalent performance of Crofer 22 APU interconnect after surface treatment and appropriate Cu-Fe based spinel coating. Therefore, it can replace the Crofer 22 APU interconnect on a cost basis. (c) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:25191 / 25209
页数:19
相关论文
共 50 条
  • [31] Cu- and Ni-doped Mn1.5Co1.5O4 spinel coatings on metallic interconnects for solid oxide fuel cells
    Park, Beom-Kyeong
    Lee, Jong-Won
    Lee, Seung-Bok
    Lim, Tak-Hyoung
    Park, Seok-Joo
    Park, Chong-Ook
    Song, Rak-Hyun
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (27) : 12043 - 12050
  • [32] Effects of Thermal Cycling on the Formation of Oxide Scale of Fe-Cr Alloy Interconnects for Solid Oxide Fuel Cells
    Horita, Teruhisa
    Yoshinaga, Masashi
    Kishimoto, Haruo
    Yamaji, Katsuhiko
    Brito, Manuel E.
    Xiong, YuePing
    Yokokawa, Harumi
    INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2011, 8 (06) : 1374 - 1381
  • [33] Diffusion of oxygen in the scales of Fe-Cr alloy interconnects and oxide coating layer for solid oxide fuel cells
    Horita, Teruhisa
    Kishimoto, Haruo
    Yamaj, Katsuhiko
    Xiong, Yueping
    Brito, Manuel E.
    Yokokawa, Harumi
    Baba, Yoshitaka
    Ogasawara, Kei
    Kameda, Harukuni
    Matsuzaki, Yoshio
    Yamashita, Satoshi
    Yasuda, Nobutaka
    Uehara, Toshihiro
    SOLID STATE IONICS, 2008, 179 (38) : 2216 - 2221
  • [34] Electrical contacts between cathodes and metallic interconnects in solid oxide fuel cells
    Yang, ZG
    Xia, GG
    Singh, P
    Stevenson, JW
    JOURNAL OF POWER SOURCES, 2006, 155 (02) : 246 - 252
  • [35] Promises and problems with metallic interconnects for reduced temperature solid oxide fuel cells
    Hou, PY
    Huang, KQ
    Bakker, WT
    SOLID OXIDE FUEL CELLS (SOFC VI), 1999, 99 (19): : 737 - 748
  • [36] ELECTRICAL CONTACTS BETWEEN CATHODES AND METALLIC INTERCONNECTS IN SOLID OXIDE FUEL CELLS
    Yang, Zhenguo
    Xia, Guanguang
    Stevenson, Jeffry W.
    ADVANCES IN SOLID OXIDE FUEL CELLS, 2005, 26 (04): : 217 - 224
  • [37] Stability of Haynes 242 as metallic interconnects of solid oxide fuel cells (SOFCs)
    Liu, Y.
    Zhu, J.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (15) : 7936 - 7944
  • [38] Opportunity of metallic interconnects for solid oxide fuel cells: a status on contact resistance
    Zhu, WZ
    Deevi, SC
    MATERIALS RESEARCH BULLETIN, 2003, 38 (06) : 957 - 972
  • [39] Metallic interconnectors for solid oxide fuel cells - a review
    Quadakkers, WJ
    Piron-Abellan, J
    Shemet, V
    Singheiser, L
    MATERIALS AT HIGH TEMPERATURES, 2003, 20 (02) : 115 - 127
  • [40] Effects of Ni-Doping in CuMn2O4 Spinel Coatings for Interconnects in Solid Oxide Fuel Cells
    Zhu, Zhikuan
    Sun, Zhihao
    Gopalan, Srikanth
    Pal, Uday B.
    Hussain, A. Mohammed
    Dale, Nilesh
    Furuya, Yoshihisa
    Basu, Soumendra N.
    JOM, 2025, 77 (02) : 719 - 728