Review: Influence of alloy addition and spinel coatings on Cr-based metallic interconnects of solid oxide fuel cells

被引:69
|
作者
Hassan, Muhammad Aqib [1 ]
Mamat, Othman Bin [1 ]
Mehdi, Muhammad [2 ,3 ]
机构
[1] Univ Teknol Petronas, Dept Mech Engn, Seri Iskandar 32610, Perak Darul Rid, Malaysia
[2] Korea Inst Energy Res, Hydrogen Lab, 152 Gajeong Ro, Daejeon 34129, South Korea
[3] Univ Sci & Technol, Adv Energy & Syst Engn, 217 Gajeong Ro, Daejeon 34113, South Korea
关键词
Solid oxide fuel cell; Cr-based metallic interconnects; Cr-migration; Spinel coatings; Crofer; 22; APU; SUS; 430; FERRITIC STAINLESS-STEEL; CROFER; 22; APU; AREA-SPECIFIC RESISTANCE; MN-CO-O; OXIDATION BEHAVIOR; SOFC INTERCONNECT; PROTECTIVE-COATINGS; ELECTRICAL BEHAVIOR; THERMAL-EXPANSION; COBALT SPINEL;
D O I
10.1016/j.ijhydene.2020.06.234
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Solid oxide fuel cell (SOFC) is the modern eco-friendly technology of fuel cell power generation system. It generates electricity from a redox chemical reaction without producing hazardous gases. It consists of anode, cathode and electrolyte. It is operated in the form of stack connected by interconnects to boost-up power output. The recent development of low-temperature (600 degrees C-800 degrees C) brings an opportunity to use metallic interconnects over ceramics. Cr-based metallic interconnects are one of the prominent metallic interconnects. They offer chemical inertness, thermal stability, compatible coefficient of thermal expansion and highly dense structure. However, the Cr-migration towards the cathode side is the major problem in them which adversely affect the SOFCs performance. Therefore a good oxidation resistance without sacrificing electrical conductivity is required. To resolve this issue, several alloying elements and spinel coatings have experimented. These spinel coatings are the thin solid films of Mn, Co, Cu and rare earth metals. This review concluded that the Mn-Co based spinal coating showed excellent performance in reducing the Cr migration in specially designed expensive Crofer 22 APU interconnect. However, the emerging low-cost ferritic interconnects also show their best results with Cu-Fe based spinel coating. Among them, the SUS-430 interconnect shows the equivalent performance of Crofer 22 APU interconnect after surface treatment and appropriate Cu-Fe based spinel coating. Therefore, it can replace the Crofer 22 APU interconnect on a cost basis. (c) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:25191 / 25209
页数:19
相关论文
共 50 条
  • [21] Oxide scale formation on different metallic interconnects for solid oxide fuel cells
    Miguel-Perez, Veronica
    Martinez-Amesti, Ana
    Luisa No, Maria
    Larranaga, Aitor
    Isabel Arriortua, Maria
    CORROSION SCIENCE, 2012, 60 : 38 - 49
  • [22] A novel low Cr-containing Fe-Cr-Co alloy for metallic interconnects in planar intermediate temperature solid oxide fuel cells
    Zhang, Wenying
    Yan, Dong
    Yang, Jie
    Chen, Jing
    Chi, Bo
    Pu, Jian
    Li, Jian
    JOURNAL OF POWER SOURCES, 2014, 271 : 25 - 31
  • [23] Protective coatings for Cr2O3-forming interconnects of solid oxide fuel cells
    Liu, Y.
    Chen, D. Y.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (22) : 9220 - 9226
  • [24] Protective coatings for Cr2O3-forming interconnects of solid oxide fuel cells
    Materials Science and Engineering Program, Department of Chemical, Materials and Biomolecular Engineering, Institute of Materials Science, University of Connecticut, Storrs, CT 06269, United States
    Int J Hydrogen Energy, 22 (9220-9226):
  • [25] The effects of thermal aging on metallic interconnects of solid oxide fuel cells
    Yung, T. -Y.
    Tseng, H. -P.
    Yang, P.
    Liu, L. -K.
    MATERIALS RESEARCH INNOVATIONS, 2013, 17 : 129 - 135
  • [26] High temperature corrosion of metallic interconnects in solid oxide fuel cells
    Bastidas, D.M.
    Revista de Metalurgia (Madrid), 2006, 42 (06): : 425 - 443
  • [27] High temperature corrosion of metallic interconnects in solid oxide fuel cells
    Bastidas, D. M.
    REVISTA DE METALURGIA, 2006, 42 (06) : 425 - 443
  • [28] EFFECT OF CONDUCTING OXIDE COATINGS ON CROFER22APU USED AS METALLIC INTERCONNECTS FOR SOLID OXIDE FUEL CELLS
    Pyo, Seong-Soo
    Lee, Seung-Bok
    Lim, Tak-Hyoung
    Song, Rak-Hyun
    Hyun, Sang-Hoon
    Shin, Dong-Ryul
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY, 2009, : 909 - 911
  • [29] Recent advances on spinel-based protective coatings for solid oxide cell metallic interconnects produced by electrophoretic deposition
    Zanchi, E.
    Sabato, A. G.
    Molin, S.
    Cempura, G.
    Boccaccini, A. R.
    Smeacetto, F.
    MATERIALS LETTERS, 2021, 286
  • [30] Ceramic Materials for Interconnects in Solid Oxide Fuel Cells - A Review
    Park, Beom-Kyeong
    Song, Rak-Hyun
    Lee, Seung-Bok
    Lim, Tak-Hyoung
    Park, Seok-Joo
    Park, Chong-Ook
    Lee, Jong-Won
    JOURNAL OF THE KOREAN CERAMIC SOCIETY, 2014, 51 (04) : 231 - 242