Comparison of three analytical methods for cocaine analysis of illicit powders

被引:10
|
作者
Campanella, L [1 ]
Colapicchioni, C [1 ]
Tomassetti, M [1 ]
Dezzi, S [1 ]
机构
[1] UNIV ROMA LA SAPIENZA,IST MED LEGALE,I-00161 ROME,ITALY
关键词
analysis; cocaine hydrochloride; free base; ISFET;
D O I
10.1016/S0731-7085(95)01758-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new cocaine-sensitive ISFET device based on a cocaine-reineckate ion-pair complex dispersed in a PVC-sebacate matrix has been fabricated. This sensor displays a linear range for cocaine hydrochloride between about 3 x 10(-6) and 2 x 10(-2) M and a fast response (less than or equal to 25 s), which remains almost constant over the pH range 3-7. The sensor has been applied to the analysis of authentic illicit powders containing cocaine hydrochloride and other substances commonly associated with it, or of cocaine free base (crack). Experimental results were compared with those obtained employing two more common instrumental methods of analysis: gas chromatography (GC), and UV absorption spectrometry (the latter applied directly or based on second derivative absorption spectroscopy). Good agreement was found between results obtained by ISFET and GC methods, while UV absorption spectrophotometry proved suitable only in the case of pure cocaine hydrochloride and free base, or in samples also containing lidocaine, but using second derivative absorption spectroscopy.
引用
收藏
页码:1047 / 1054
页数:8
相关论文
共 50 条
  • [31] COMPARISON OF ANALYTICAL METHODS
    BEILBY, AL
    JOURNAL OF CHEMICAL EDUCATION, 1972, 49 (10) : 679 - &
  • [32] Comparison of Analytical and Clinical Performance of Three Methods for Detection of Clostridium difficile
    LaSala, P. Rocco
    Svensson, Annika M.
    Mohammad, Amin A.
    Perrotta, Peter L.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2012, 136 (05) : 527 - 531
  • [33] Comparison of Three Analytical Methods for the Determination of Quinolones in Pig Muscle Samples
    Inmaculada Jiménez-Díaz
    María Pilar Hermo
    Oscar Ballesteros
    Alberto Zafra-Gómez
    Dolores Barrón
    José Barbosa
    Alberto Navalón
    Chromatographia, 2013, 76 : 707 - 713
  • [34] Comparison of three analytical methods for PCBs-containing liquid wastes
    Kim, Kyeo Keun
    Yoon, Seong Kyu
    Bae, Woo Keun
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (03): : 278 - 283
  • [35] Comparison of three analytical methods for superoxide produced by activated immune cells
    Zhu, Zhixiang
    Guo, Ran
    Li, Yunqian
    Li, Shanshan
    Tu, Pengfei
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2020, 101
  • [36] Comparison of three analytical methods to determine serum in refrigerated raw milk
    Souza, C. M.
    Nicolau, E. S.
    Lage, M. E.
    Mesquita, A. J.
    Coelho, K. O.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2018, 70 (02) : 606 - 614
  • [37] COMPARISON OF ANALYTICAL METHODS
    KORMENDY, L
    MIHALYI, V
    ZUKAL, E
    CSIBA, A
    MEAT SCIENCE, 1989, 26 (03) : 193 - 207
  • [38] Comparison and Analysis of Three Regression Testing Methods
    Qin, Mengqiu
    Cai, Haini
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER ENGINEERING AND ELECTRONICS (ICECEE 2015), 2015, 24 : 1419 - 1424
  • [39] Comparison of three methods for robust redundancy analysis
    Oliveira, MR
    Branco, JA
    DEVELOPMENTS IN ROBUST STATISTICS, 2003, : 287 - 295
  • [40] ANALYTICAL STUDIES ON ILLICIT HEROIN .2. COMPARISON OF SAMPLES
    HUIZER, H
    JOURNAL OF FORENSIC SCIENCES, 1983, 28 (01) : 40 - 48