Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection system

被引:10
|
作者
Pawlicová, Z
Albert-García, JR
Sahuquillo, I
Mateo, JVG
Icardo, MC
Calatayud, JM [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, Valencia, Spain
[2] Univ Cardenal Herrera, Dept Chem Biochem & Mol Biol, CEU, Valencia, Spain
[3] Univ Politecn Valencia, Dept Chem, E-46071 Valencia, Spain
关键词
D O I
10.2116/analsci.22.29
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l(-1)) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples h(-1) of Bromoxynil in a wide interval of concentrations, over the range 5 x 10(-3) - 1 mg l(-1); the detection limit was 5 x 10(-3) mg l(-1). The RSD (n = 24) at 0.25 mg l(-1) of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [41] Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
    Udnan, Y
    McKelvie, ID
    Grace, MR
    Jakmunee, J
    Grudpan, K
    [J]. TALANTA, 2005, 66 (02) : 461 - 466
  • [42] Chemiluminescence determination of molybdenum by on-line reduction with a flow injection system
    Zhu, ZJ
    [J]. CHINESE CHEMICAL LETTERS, 2000, 11 (05) : 427 - 430
  • [43] Chemiluminescence Determination of Molybdenum by on-Line Reduction with a Flow Injection System
    Zhi Jia ZHU (Experimental Center
    [J]. Chinese Chemical Letters, 2000, (05) : 427 - 430
  • [44] Determination of Menadione Sodium Bisulfite in Pharmaceutical Preparations by Flow-Injection On-line Photochemical Spectrofluorometry
    Qiaohong He
    Zhixin Wang
    Xiaoxia Cao
    Hengwu Chen
    Yinfen Ke
    [J]. Analytical Sciences, 2001, 17 : 1209 - 1212
  • [45] On-line column preconcentration for the determination of cobalt in sea water by flow-injection chemiluminescence detection
    Hirata, S
    Aihara, M
    Hashimoto, Y
    Mallika, GV
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (5-6): : 676 - 679
  • [46] Flow-injection chemiluminescence determination of hydrazine using on-line electrogenerated BrO- as the oxidant
    Li, BX
    Zhang, ZJ
    Zheng, XW
    Xu, CL
    [J]. CHEMIA ANALITYCZNA, 2000, 45 (05): : 709 - 717
  • [47] Determination of menadione sodium bisulfite in pharmaceutical preparations by flow-injection on-line photochemical spectrofluorometry
    He, QH
    Wang, ZX
    Cao, XX
    Chen, HW
    Ke, YF
    [J]. ANALYTICAL SCIENCES, 2001, 17 (10) : 1209 - 1212
  • [48] Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO- as oxidant
    Zheng, XW
    Zhang, ZJ
    [J]. ANALYST, 1999, 124 (05) : 763 - 766
  • [49] DETERMINATION OF THE PESTICIDE GUTHION BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    [J]. ELECTROANALYSIS, 1990, 2 (06) : 487 - 491
  • [50] Flame atomic absorption determination of trace cobalt in steel samples using a flow-injection on-line separation system
    Yebra-Biurrun, MC