MEASUREMENT OF THE EFFICIENCY OF EVACUATED TUBE SOLAR COLLECTORS UNDER VARIOUS OPERATING CONDITIONS

被引:11
|
作者
Zubriski, S. E. [1 ]
Dick, K. J. [2 ]
机构
[1] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Biosyst Engn, Alternative Village, Winnipeg, MB, Canada
来源
JOURNAL OF GREEN BUILDING | 2012年 / 7卷 / 03期
关键词
solar collector; evacuated tube; solar hot water; PERFORMANCE;
D O I
10.3992/jgb.7.3.114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating efficiency of evacuated tubes themselves under varying environmental conditions and installation scenarios, independent of water and space heating auxiliary equipment, are not readily available values. Further, Manitoba specific data has not been established. The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. These design values are of use for appropriate sizing of water or space heating systems, system configuration and optimization, and calculation of return on investment. The scope of the research project was limited to the efficiency of various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% between the different collector configurations, as observed from the overlay graph of results. When the efficiency of a collector is considered within a system it is proposed that effectiveness may be a better measure of overall performance.
引用
收藏
页码:114 / 130
页数:17
相关论文
共 50 条
  • [31] Experimental Investigation of Evacuated Gas Tube Solar Collectors for Water Heating Applications
    Arslan, Muhammad
    Mahmood, Anzar
    Rafiq, Iqra
    Kousar, Anila
    2018 INTERNATIONAL CONFERENCE ON ENGINEERING & EMERGING TECHNOLOGIES (ICEET), 2018, : 82 - 88
  • [32] Design of a solar-driven cogeneration system using flat plate collectors and evacuated tube collectors
    Bellos, Evangelos
    Tzivanidis, Christos
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (11) : 5841 - 5851
  • [33] Theoretical investigation of the thermal performance of evacuated heat pipe solar collector with optimum tilt angle under various operating conditions
    Tong, Y.
    Kim, H. M.
    Cho, H. H.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (02) : 903 - 913
  • [34] Thermal performance of two evacuated tube solar collectors with flat heat pipes
    Zhang, Dengke
    Diao, Yanhua
    Wang, Zeyu
    Pan, Yawen
    Sun, Mengda
    Wang, Xinran
    Du, Peiyuan
    Zhao, Yaohua
    APPLIED THERMAL ENGINEERING, 2024, 241
  • [35] Performance analysis and comparison of concentrated evacuated tube heat pipe solar collectors
    Nkwetta, Dan Nchelatebe
    Smyth, Mervyn
    APPLIED ENERGY, 2012, 98 : 22 - 32
  • [36] EXPERIMENTAL DAILY ENERGY PERFORMANCE OF FLAT PLATE AND EVACUATED TUBE SOLAR COLLECTORS
    Zambolin, Enrico
    Del Col, Davide
    Padovan, Andrea
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 853 - 862
  • [37] Research on thermal performance and flow resistance of evacuated tube solar air collectors
    Zeng, D. (zengdongqi6@163.com), 1600, Science Press (35):
  • [38] Dual use of carbon nanotube selective coatings in evacuated tube solar collectors
    Martinez, Patricia M.
    Pozdin, Vladimir A.
    Papadimitratos, Alexios
    Holmes, William
    Hassanipour, Fatemeh
    Zakhidov, Anvar A.
    CARBON, 2017, 119 : 133 - 141
  • [39] Theoretical investigation of the thermal performance of evacuated heat pipe solar collector with optimum tilt angle under various operating conditions
    Y. Tong
    H. M. Kim
    H. H. Cho
    Journal of Mechanical Science and Technology, 2016, 30 : 903 - 913
  • [40] The research on thermal and economic performance of solar desalination system with evacuated tube collectors
    Liu, Xiaohua
    Chen, Wenbo
    Shen, Shengqiang
    Gu, Ming
    Cao, Guojian
    DESALINATION AND WATER TREATMENT, 2013, 51 (19-21) : 3728 - 3734