MEASUREMENT OF THE EFFICIENCY OF EVACUATED TUBE SOLAR COLLECTORS UNDER VARIOUS OPERATING CONDITIONS

被引:11
|
作者
Zubriski, S. E. [1 ]
Dick, K. J. [2 ]
机构
[1] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Biosyst Engn, Alternative Village, Winnipeg, MB, Canada
来源
JOURNAL OF GREEN BUILDING | 2012年 / 7卷 / 03期
关键词
solar collector; evacuated tube; solar hot water; PERFORMANCE;
D O I
10.3992/jgb.7.3.114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating efficiency of evacuated tubes themselves under varying environmental conditions and installation scenarios, independent of water and space heating auxiliary equipment, are not readily available values. Further, Manitoba specific data has not been established. The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. These design values are of use for appropriate sizing of water or space heating systems, system configuration and optimization, and calculation of return on investment. The scope of the research project was limited to the efficiency of various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% between the different collector configurations, as observed from the overlay graph of results. When the efficiency of a collector is considered within a system it is proposed that effectiveness may be a better measure of overall performance.
引用
收藏
页码:114 / 130
页数:17
相关论文
共 50 条
  • [21] Thermoeconomic and environmental analysis of solar flat plate and evacuated tube collectors in cold climatic conditions
    Sokhansefat, Tahmineh
    Kasaeian, Alibakhsh
    Rahmani, Kiana
    Heidari, Ameneh Haji
    Aghakhani, Faezeh
    Mahian, Omid
    RENEWABLE ENERGY, 2018, 115 : 501 - 508
  • [22] EVACUATED-TUBE SOLAR COLLECTOR - EFFECT OF CONTROL ON EFFICIENCY AT HIGH OPERATING TEMPERATURES
    LOUIE, WC
    MILLER, DC
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (05): : 39 - 42
  • [23] The effect of different working fluids and internal geometries on the efficiency of evacuated tube heat pipe solar collectors
    Mukuna, Jean Gad
    Gryzagoridis, Jasson
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2020, 31 (04) : 16 - 25
  • [24] Assessment of electricity and hydrogen production performance of evacuated tube solar collectors
    Atiz, Ayhan
    Karakilcik, Hatice
    Erden, Mustafa
    Karakilcik, Mehmet
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (27) : 14137 - 14144
  • [25] On the integration of phase change materials with evacuated tube solar thermal collectors
    Aramesh, M.
    Shabani, B.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 132
  • [26] Mathematical modelling of unglazed solar collectors under extreme operating conditions
    Bunea, M.
    Perers, B.
    Eicher, S.
    Hildbrand, C.
    Bony, J.
    Citherlet, S.
    SOLAR ENERGY, 2015, 118 : 547 - 561
  • [27] Thermal and economic analyses of solar desalination system with evacuated tube collectors
    Liu, Xiaohua
    Chen, Wenbo
    Gu, Ming
    Shen, Shengqiang
    Cao, Guojian
    SOLAR ENERGY, 2013, 93 : 144 - 150
  • [28] Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube
    Kim, Yong
    Seo, Taebeom
    RENEWABLE ENERGY, 2007, 32 (05) : 772 - 795
  • [29] EVACUATED-TUBE SOLAR COLLECTOR: EFFECT OF CONTROL ON EFFICIENCY AT HIGH OPERATING TEMPERATURES.
    Louie, William C.
    Miller, David C.
    ASHRAE Journal, 1978, 20 (05) : 39 - 42
  • [30] Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions
    Zambolin, E.
    Del Col, D.
    SOLAR ENERGY, 2010, 84 (08) : 1382 - 1396