A new fluorescent chemosensor for iron(III) based on the β-aminobisulfonate receptor

被引:90
|
作者
Singh, Narinder [1 ]
Kaur, Navneet [1 ]
Dunn, John [1 ]
MacKay, Martha [1 ]
Callan, John F. [1 ]
机构
[1] Robert Gordon Univ, Sch Pharm & Life Sci, Aberdeen AB10 1FR, Scotland
基金
英国工程与自然科学研究理事会;
关键词
ELECTRON-TRANSFER SENSORS; CARBOXYLIC-ACIDS; IRON; SWITCHES; STABILITY; BINDING; DESIGN; AGENTS; ION;
D O I
10.1016/j.tetlet.2008.12.041
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
A simple fluorescent sensor 1 has been developed for the determination of Fe(III) in 100% aqueous solution at pH 7.0. The sensor comprises a novel aminobisulfonate receptor joined to a naphthalene fluorophore via a methylene spacer in the fluorophore-spacer-receptor format of photoinduced electron transfer (PET) based sensors. The fluorescence emission of the sensor was quenched upon addition of Fe(III) ions, most likely due to electron/energy transfer between Fe(III) and the excited naphthalene. The sensor displayed good selectivity for Fe(III) over other physiologically relevant metal ions and can estimate Fe(III) concentration between 16 and 63 mu M. Stern Volmer analysis showed the binding stoichiometry to be 1:1 (host-guest) with a binding constant, calculated using the Benesi-Hilderbrand equation, of (7.6 +/- 0.6) x 10(4) M-1. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:953 / 956
页数:4
相关论文
共 50 条
  • [41] A new fluorescent chemosensor for Pb2+ ions based on naphthalene derivatives
    Azadbakht, Reza
    Vaisi, Hojat
    Mohamadvand, Hossain
    Khanabadi, Javad
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 145 : 575 - 579
  • [42] A new fluorescent as well as chromogenic chemosensor for anions based on an anthracene carbamate derivative
    Chen, QY
    Chen, CF
    TETRAHEDRON LETTERS, 2004, 45 (34) : 6493 - 6496
  • [43] A thiocyanate-based hybrid molecular salt as a new fluorescent chemosensor for fluoride
    Biswas, Bhaskar
    Hung, Shao-Po
    Tsai, Hui-Lien
    Ghosh, Rajarshi
    Kole, Niranjan
    JOURNAL OF COORDINATION CHEMISTRY, 2012, 65 (13) : 2280 - 2293
  • [44] A new fluorescent chemosensor for Al(III) detection with highly selective in aqueous solution and solid test paper
    Xiu, Deping
    Shi, Junjie
    Deng, Miaoran
    Song, Huihua
    Hao, Zhiqiang
    Feng, Qi
    Yu, Haitao
    JOURNAL OF MOLECULAR STRUCTURE, 2021, 1243
  • [45] Calcein as a fluorescent iron chemosensor for the determination of low molecular weight iron in biological fluids
    Ali, A
    Zhang, Q
    Dai, JS
    Huang, X
    BIOMETALS, 2003, 16 (02) : 285 - 293
  • [46] Calcein as a fluorescent iron chemosensor for the determination of low molecular weight iron in biological fluids
    Aktar Ali
    Qi Zhang
    Jisen Dai
    Xi Huang
    Biometals, 2003, 16 : 285 - 293
  • [47] An oxalamide-bridged imidazole based 'turn off' fluorescent receptor for copper(ii) and iron(iii) ions
    Murugaperumal, Parvathavarthini
    Rajendran, Praveena
    Nallathambi, Sengottuvelan
    Ayyanar, Siva
    Perdih, Franc
    Balasubramaniem, Ashokkumar
    Alagarsamy, Arun
    NEW JOURNAL OF CHEMISTRY, 2023, 47 (28) : 13342 - 13352
  • [48] An ATP fluorescent chemosensor based on a Zn(II)-complexed dipicolylamine receptor coupled with a naphthalimide chromophore
    Moro, Artur J.
    Cywinski, Piotr J.
    Koersten, Susanne
    Mohr, Gerhard J.
    CHEMICAL COMMUNICATIONS, 2010, 46 (07) : 1085 - 1087
  • [49] Benzimidazole-based tripodal receptor: Highly selective fluorescent chemosensor for iodide in aqueous solution
    Singh, Narinder
    Jang, Doo Ok
    ORGANIC LETTERS, 2007, 9 (10) : 1991 - 1994
  • [50] Design and synthesis of a new fluorescent tripod for chemosensor applications
    Makki, Mohammad S. I.
    Staneva, Desislava
    Sobahi, Tariq R.
    Bosch, Paula
    Abdel-Rahman, Reda M.
    Grabchev, Ivo
    TETRAHEDRON, 2014, 70 (49) : 9366 - 9372