Evaluation of the Reliability and Accuracy of Using Cone-beam Computed Tomography for Diagnosing Periapical Cysts from Granulomas

被引:49
|
作者
Guo, Jing [1 ]
Simon, James H. [1 ]
Sedghizadeh, Parish [1 ]
Soliman, Osman N. [1 ]
Chapman, Travis [1 ]
Enciso, Reyes [1 ]
机构
[1] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA 90089 USA
关键词
Biopsy; cone-beam computed tomography; differential diagnosis; granuloma; periapical cyst; RADICULAR CYSTS; DIFFERENTIAL-DIAGNOSIS; CBCT DEVICES; LESIONS; DOSIMETRY;
D O I
10.1016/j.joen.2013.08.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate the reliability and accuracy of cone-beam computed tomographic (CBCT) imaging against the histopathologic diagnosis for the differential diagnosis of periapical cysts (cavitated lesions) from (solid) granulomas. Methods: Thirty-six periapical lesions were imaged using CBCT scans. Apicoectomy surgeries were conducted for histopathological examination. Evaluator 1 examined each CBCT scan for the presence of 6 radiologic characteristics of a cyst (ie, location, periphery, shape, internal structure, effects on surrounding structure, and perforation of the cortical plate). Not every cyst showed all radiologic features (eg, not all cysts perforate the cortical plate). For the purpose of finding the minimum number of diagnostic criteria present in a scan to diagnose a lesion as a cyst, we conducted 6 receiver operating characteristic curve analyses comparing CBCT diagnoses with the histopathologic diagnosis. Two other independent evaluators examined the CBCT lesions. Statistical tests were conducted to examine the accuracy, inter-rater reliability, and intrarater reliability of CBCT images. Results: Findings showed that a score of >= 4 positive findings was the optimal scoring system. The accuracies of differential diagnoses of 3 evaluators were moderate (area under the curve = 0.76, 0.70, and 0.69 for evaluators 1, 2, and 3, respectively). The inter-rater agreement of the 3 evaluators was excellent (alpha = 0.87). The intrarater agreement was good to excellent (kappa = 0.71, 0.76, and 0.77). Conclusions: CBCT images can provide a moderately accurate diagnosis between cysts and granulomas.
引用
收藏
页码:1485 / 1490
页数:6
相关论文
共 50 条
  • [41] An Ex Vivo Comparison of Diagnostic Accuracy of Cone-beam Computed Tomography and Periapical Radiography in the Detection of Furcal Perforations
    Kamburoglu, Kivanc
    Yeta, Elif Naz
    Yilmaz, Funda
    JOURNAL OF ENDODONTICS, 2015, 41 (05) : 696 - 702
  • [42] Cone-beam Computed Tomography Evaluation of Maxillary Sinusitis
    Maillet, Michelle
    Bowles, Walter R.
    McClanahan, Scott L.
    John, Mike T.
    Ahmad, Mansur
    JOURNAL OF ENDODONTICS, 2011, 37 (06) : 753 - 757
  • [43] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Erdem, Sule
    Zengin, Ayse Zeynep
    Erdem, Suheda
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (11) : 1307 - 1313
  • [44] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Şule Erdem
    Ayşe Zeynep Zengin
    Şuheda Erdem
    Surgical and Radiologic Anatomy, 2020, 42 : 1307 - 1313
  • [45] Evaluation of the frequency of mucous retention cysts in the maxillary sinus in a Turkish population using cone-beam computed tomography
    Lacin, Nihat
    Tatar, Birkan
    MAKARA JOURNAL OF HEALTH RESEARCH, 2019, 23 (02): : 68 - 71
  • [46] Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography
    Kamburoglu, K.
    Kilic, C.
    Ozen, T.
    Horasan, S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) : 95 - 99
  • [47] Preliminary Evaluation of the Dosimetric Accuracy of Cone-beam Computed Tomography for Cases with Respiratory Motion
    Kim, Dong Wook
    Bae, Sunhyun
    Chung, Weon Kuu
    Lee, Yoonhee
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (07) : 1070 - 1077
  • [48] Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull
    Berco, Mauricio
    Rigali, Paul H., Jr.
    Miner, R. Matthew
    DeLuca, Stephelynn
    Anderson, Nina K.
    Will, Leslie A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 17.e1 - 17.e9
  • [49] Evaluation of the accuracy of cone-beam computed tomography for measuring intraoral soft tissue thickness
    Wang, Xue-Yu
    Shi, Yan-Wei
    Zhou, Song
    Chen, Yu-Hui
    Yan, Shu
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (01): : 37 - 44
  • [50] Preliminary evaluation of the dosimetric accuracy of cone-beam computed tomography for cases with respiratory motion
    Dong Wook Kim
    Sunhyun Bae
    Weon Kuu Chung
    Yoonhee Lee