Evaluation of the Reliability and Accuracy of Using Cone-beam Computed Tomography for Diagnosing Periapical Cysts from Granulomas

被引:49
|
作者
Guo, Jing [1 ]
Simon, James H. [1 ]
Sedghizadeh, Parish [1 ]
Soliman, Osman N. [1 ]
Chapman, Travis [1 ]
Enciso, Reyes [1 ]
机构
[1] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA 90089 USA
关键词
Biopsy; cone-beam computed tomography; differential diagnosis; granuloma; periapical cyst; RADICULAR CYSTS; DIFFERENTIAL-DIAGNOSIS; CBCT DEVICES; LESIONS; DOSIMETRY;
D O I
10.1016/j.joen.2013.08.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate the reliability and accuracy of cone-beam computed tomographic (CBCT) imaging against the histopathologic diagnosis for the differential diagnosis of periapical cysts (cavitated lesions) from (solid) granulomas. Methods: Thirty-six periapical lesions were imaged using CBCT scans. Apicoectomy surgeries were conducted for histopathological examination. Evaluator 1 examined each CBCT scan for the presence of 6 radiologic characteristics of a cyst (ie, location, periphery, shape, internal structure, effects on surrounding structure, and perforation of the cortical plate). Not every cyst showed all radiologic features (eg, not all cysts perforate the cortical plate). For the purpose of finding the minimum number of diagnostic criteria present in a scan to diagnose a lesion as a cyst, we conducted 6 receiver operating characteristic curve analyses comparing CBCT diagnoses with the histopathologic diagnosis. Two other independent evaluators examined the CBCT lesions. Statistical tests were conducted to examine the accuracy, inter-rater reliability, and intrarater reliability of CBCT images. Results: Findings showed that a score of >= 4 positive findings was the optimal scoring system. The accuracies of differential diagnoses of 3 evaluators were moderate (area under the curve = 0.76, 0.70, and 0.69 for evaluators 1, 2, and 3, respectively). The inter-rater agreement of the 3 evaluators was excellent (alpha = 0.87). The intrarater agreement was good to excellent (kappa = 0.71, 0.76, and 0.77). Conclusions: CBCT images can provide a moderately accurate diagnosis between cysts and granulomas.
引用
收藏
页码:1485 / 1490
页数:6
相关论文
共 50 条
  • [31] A Phantom Study on Target Localization Accuracy Using Cone-Beam Computed Tomography
    Yan, Hui
    Zhang, Liwei
    Yin, Fang-Fang
    CLINICAL MEDICINE INSIGHTS-ONCOLOGY, 2008, 2 : 501 - 510
  • [32] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [33] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095
  • [34] Reliability of cone-beam computed tomography for temporomandibular joint analysis
    Gorucu-Coskuner, Hande
    Atik, Ezgi
    El, Hakan
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (02) : 81 - 88
  • [35] Evaluation of canalis basilaris medianus using cone-beam computed tomography
    Syed, Ali Z.
    Zahedpasha, Samir
    Rathore, Sonali A.
    Mupparapu, Mel
    IMAGING SCIENCE IN DENTISTRY, 2016, 46 (02) : 141 - 144
  • [36] Evaluation of the morphology of the genial tubercle using cone-beam computed tomography
    Nejaim, Y.
    Duarte Moreira, D.
    Nolasco Fernandes, A. B.
    de Souza, M. M. G.
    Groppo, F. C.
    Haiter Neto, F.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2018, 56 (02): : 155 - 156
  • [37] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01): : 31 - 35
  • [38] Morphological evaluation of the mandibular lingula using cone-beam computed tomography
    Senel, B.
    Ozkan, A.
    Altug, H. A.
    FOLIA MORPHOLOGICA, 2015, 74 (04) : 497 - 502
  • [39] Accuracy of Digital Periapical Radiography and Cone-beam Computed Tomography for Diagnosis of Natural and Simulated External Root Resorption
    Deliga Schroeder, Angela Graciela
    Westphalen, Fernando Henrique
    Schroeder, Julio Cesar
    Fernandes, Angela
    Ditzel Westphalen, Vania Portela
    JOURNAL OF ENDODONTICS, 2018, 44 (07) : 1151 - 1158
  • [40] Diagnostic Accuracy of Periapical Radiography and Cone-beam Computed Tomography in Identifying Root Canal Configuration of Human Premolars
    Sousa, Thiago Oliveira
    Haiter-Neto, Francisco
    Leandro Nascimento, Eduarda Helena
    Peroni, Leonardo Vieira
    Freitas, Deborah Queiroz
    Hassan, Bassam
    JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1176 - 1179