Comparison of right and left common carotid arteries of horses and mules by two-dimensional ultrasound and Doppler flow

被引:0
|
作者
Fogaca, Jessica L. [1 ]
Castiglioni, Maria Cristina R. [2 ]
Vettorato, Michel C. [2 ]
Silva, Jeana P. [2 ]
Bueno, Lais M. C. [2 ]
Filadelpho, Andre Luis [2 ]
Puoli-Filho, Jose Nicolau P. [2 ]
Machado, Vania Maria V. [1 ]
机构
[1] Univ Estadual Paulista Julio de Mesquita Filho Un, dept Reprod Anim & Radiol Vet, Fac Med Vet & Zootecnia FMVZ, Campus Botucatu,Dist Rubiao Jr S-N, Botucatu, SP, Brazil
[2] Univ Estadual Paulista Julio de Mesquita Filho Un, Fac Med Vet & Zootecnia FMVZ, Campus Botucatu,Dist Rubiao Jr S-N, Botucatu, SP, Brazil
来源
PESQUISA VETERINARIA BRASILEIRA | 2020年 / 40卷 / 07期
关键词
Carotid arteries; horses; mules; two-dimensional ultrasound; Doppler flow; vases; diagnostic image; blood flow; INTIMA-MEDIA THICKNESS; EXTERNAL JUGULAR-VEIN; BLOOD-FLOW; ULTRASONOGRAPHIC EVALUATION; STENOSIS; ATHEROSCLEROSIS; HEALTHY; CATTLE; SINUS; BODY;
D O I
10.1590/1678-5150-PVB-6433
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
In ultrasonography, the bi-dimensional mode (B-mode) allows the morphological and morphometric evaluation of several types of organs and tissues, while the Doppler mode allows the hemodynamic evaluation. In humans, the Doppler evaluation is routinely used in the assessment of important arteries and veins, such as the carotid arteries and jugular veins, with significant differences between genres and sides. However, in veterinary medicine, this diagnostic method is not yet well established in the evaluation of the carotid arteries, with only few reports in domestic horses. This study aims to compare the right and left common carotid arteries of domestic horses and mules using bi-dimensional and Doppler ultrasound evaluation. The common carotid arteries from 10 domestic horses (five males and five females) and 10 mules (five males and five females) were evaluated. The following variables were measured at three different portions (cranial, middle and caudal): diameter, intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV) and final diastolic velocity (fDV). No significant differences were observed in the hi-dimensional variables (diameter and IMT) between the common carotid arteries of horses and mules, regardless of gender (p>0.05). In Doppler mode, there were no significant differences between carotid values in male and female horses (p> 0.05). In the mules, it was only possible to observe differences between the RI and PI values (p<0.05), being higher on the left side (0.81 and 2.04 respectively), and the fDV (p<0.05) higher, on the right side (14.35) in males. As for females, there was only in fDV (p<0.05), with the upper right side (23.16). Diameters and IMT do not differ between sides in horses and mules in B-mode ultrasound. Spectral Doppler in horses does not differ between sides, regardless of gender. As for mules, males differ in RI, PI and fDV between sides, while females differ only in fDV.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [41] PULMONARY-ARTERY ORIGIN OF THE LEFT CORONARY-ARTERY - DIAGNOSIS BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY, PULSED DOPPLER ULTRASOUND AND COLOR FLOW MAPPING
    SCHMIDT, KG
    COOPER, MJ
    SILVERMAN, NH
    STANGER, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (02) : 396 - 402
  • [42] NONINVASIVE ASSESSMENT OF LEFT AND RIGHT VENTRICULAR FILLING IN MYOCARDIAL-INFARCTION WITH A TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHIC METHOD
    FUJII, J
    YAZAKI, Y
    SAWADA, H
    AIZAWA, T
    WATANABE, H
    KATO, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (05) : 1155 - 1160
  • [43] TWO-DIMENSIONAL FLOW AT RIGHT ANGLES TO A FLEXIBLE MEMBRANE
    NEWMAN, BG
    LOW, HT
    AERONAUTICAL QUARTERLY, 1981, 32 (AUG): : 243 - 269
  • [44] PULSED DOPPLER - DETERMINATION OF BLOOD VELOCITY FLOW AND VOLUME FLOW IN NORMAL AND DISEASED COMMON CAROTID ARTERIES IN MAN
    FITZGERALD, DE
    SHAUGHNESSY, AM
    KEAVENY, VT
    BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (654): : 481 - 481
  • [45] Comparison of Unet architectures for segmentation of the left ventricle endocardial border on two-dimensional ultrasound images
    Zyuzin, Vasily
    Chumarnaya, Tatiana
    2019 URAL SYMPOSIUM ON BIOMEDICAL ENGINEERING, RADIOELECTRONICS AND INFORMATION TECHNOLOGY (USBEREIT), 2019, : 110 - 113
  • [46] NONINVASIVE DETECTION OF LEFT ANTERIOR DESCENDING CORONARY-ARTERY FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY
    FUSEJIMA, K
    TAKAHARA, Y
    NAKAMURA, T
    MASUDA, Y
    INAGAKI, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (08): : 749 - 750
  • [47] NONINVASIVE DETECTION OF LEFT ANTERIOR DESCENDING CORONARY-ARTERY FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY
    FUSEJIMA, K
    TAKAHARA, Y
    MIYATAKE, K
    MASUDA, Y
    INAGAKI, Y
    CIRCULATION, 1986, 74 (04) : 271 - 271
  • [48] TRANSESOPHAGEAL TWO-DIMENSIONAL ECHO-DOPPLER VISUALIZATION OF LEFT MAIN CORONARY ARTERIAL ANATOMY AND FLOW
    KYO, S
    TAKAMOTO, S
    MATSUMURA, M
    YOKOTE, Y
    OMOTO, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A179 - A179
  • [49] Transthoracic versus transesophageal two-dimensional echo Doppler determination of flow velocity in the left atrial appendage
    Carranza, C
    Abufhele, A
    Cartes, F
    Forero, A
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (04): : 357 - 361
  • [50] CORRECTED TRANSPOSITION OF THE GREAT-ARTERIES - EVALUATION BY TWO-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHY
    MEISSNER, MD
    PANIDIS, IP
    ESHAGHPOUR, E
    MINTZ, GS
    ROSS, J
    AMERICAN HEART JOURNAL, 1986, 111 (03) : 599 - 601