Comparison of right and left common carotid arteries of horses and mules by two-dimensional ultrasound and Doppler flow

被引:0
|
作者
Fogaca, Jessica L. [1 ]
Castiglioni, Maria Cristina R. [2 ]
Vettorato, Michel C. [2 ]
Silva, Jeana P. [2 ]
Bueno, Lais M. C. [2 ]
Filadelpho, Andre Luis [2 ]
Puoli-Filho, Jose Nicolau P. [2 ]
Machado, Vania Maria V. [1 ]
机构
[1] Univ Estadual Paulista Julio de Mesquita Filho Un, dept Reprod Anim & Radiol Vet, Fac Med Vet & Zootecnia FMVZ, Campus Botucatu,Dist Rubiao Jr S-N, Botucatu, SP, Brazil
[2] Univ Estadual Paulista Julio de Mesquita Filho Un, Fac Med Vet & Zootecnia FMVZ, Campus Botucatu,Dist Rubiao Jr S-N, Botucatu, SP, Brazil
来源
PESQUISA VETERINARIA BRASILEIRA | 2020年 / 40卷 / 07期
关键词
Carotid arteries; horses; mules; two-dimensional ultrasound; Doppler flow; vases; diagnostic image; blood flow; INTIMA-MEDIA THICKNESS; EXTERNAL JUGULAR-VEIN; BLOOD-FLOW; ULTRASONOGRAPHIC EVALUATION; STENOSIS; ATHEROSCLEROSIS; HEALTHY; CATTLE; SINUS; BODY;
D O I
10.1590/1678-5150-PVB-6433
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
In ultrasonography, the bi-dimensional mode (B-mode) allows the morphological and morphometric evaluation of several types of organs and tissues, while the Doppler mode allows the hemodynamic evaluation. In humans, the Doppler evaluation is routinely used in the assessment of important arteries and veins, such as the carotid arteries and jugular veins, with significant differences between genres and sides. However, in veterinary medicine, this diagnostic method is not yet well established in the evaluation of the carotid arteries, with only few reports in domestic horses. This study aims to compare the right and left common carotid arteries of domestic horses and mules using bi-dimensional and Doppler ultrasound evaluation. The common carotid arteries from 10 domestic horses (five males and five females) and 10 mules (five males and five females) were evaluated. The following variables were measured at three different portions (cranial, middle and caudal): diameter, intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV) and final diastolic velocity (fDV). No significant differences were observed in the hi-dimensional variables (diameter and IMT) between the common carotid arteries of horses and mules, regardless of gender (p>0.05). In Doppler mode, there were no significant differences between carotid values in male and female horses (p> 0.05). In the mules, it was only possible to observe differences between the RI and PI values (p<0.05), being higher on the left side (0.81 and 2.04 respectively), and the fDV (p<0.05) higher, on the right side (14.35) in males. As for females, there was only in fDV (p<0.05), with the upper right side (23.16). Diameters and IMT do not differ between sides in horses and mules in B-mode ultrasound. Spectral Doppler in horses does not differ between sides, regardless of gender. As for mules, males differ in RI, PI and fDV between sides, while females differ only in fDV.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [31] NONINVASIVE EVALUATION OF MID-LEFT VENTRICULAR OBSTRUCTION BY TWO-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHY AND COLOR FLOW DOPPLER ECHOCARDIOGRAPHY
    BLAZER, D
    KOTLER, MN
    PARRY, WR
    WERTHEIMER, J
    NAKHJAVAN, FK
    AMERICAN HEART JOURNAL, 1987, 114 (05) : 1162 - 1168
  • [32] Tissue Doppler Imaging and Two-Dimensional Speckle Tracking of Left Ventricular Function in Healthy Horses After Clenbuterol Application
    Gehlen, Heidrun
    Neukirch, Susanne
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2013, 33 (12) : 1076 - 1081
  • [33] Right and left common carotid arteries arising from the branchiocephalic, a rare variation of the aortic arch
    Panagouli, Eleni
    Tsoucalas, Gregory
    Papaioannou, Theodoros
    Fiska, Aliki
    Venieratos, Dionysios
    Skandalakis, Panagiotis
    ANATOMY & CELL BIOLOGY, 2018, 51 (03) : 215 - 217
  • [34] Left versus right intra-abdominal umbilical arteries: A comparison of their Doppler waveforms
    Janeczek, S
    Macmillan, W
    Besinger, R
    Weisenborn, E
    Mittendorf, R
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S185 - S185
  • [35] Left Versus Right Intra-abdominal Umbilical Arteries Comparison of Their Doppler Waveforms
    Janeczek, Susan
    Karlman, Roberta
    MacMillan, William
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (05) : 679 - 683
  • [36] CONTINUOUS AND SIMULTANEOUS ULTRASOUND DOPPLER VELOCIMETRY OF THE INTERNAL CAROTID AND VERTEBRAL ARTERIES - PRELIMINARY-OBSERVATIONS OF CEREBRAL BLOOD-FLOW CHANGES WITH COMMON CAROTID COMPRESSION
    MAKINAGA, G
    KONDO, H
    OCHI, N
    AKASHI, K
    FURUKAWA, T
    MATSUMURA, K
    TANAKA, S
    NISHIMURA, T
    KANEKO, Z
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (6-7): : 637 - 643
  • [37] Doppler sonograpy with dynamic testing in a case of aortic dissection extending to the innominate and right common carotid arteries
    Bonnin, P
    Giannesini, C
    Amah, G
    Kevorkian, JP
    Woimant, F
    Levy, BI
    NEURORADIOLOGY, 2003, 45 (07) : 472 - 475
  • [38] Doppler sonograpy with dynamic testing in a case of aortic dissection extending to the innominate and right common carotid arteries
    P. Bonnin
    C. Giannesini
    G. Amah
    J. P. Kevorkian
    F. Woimant
    B. I. Levy
    Neuroradiology, 2003, 45 : 472 - 475
  • [39] Is three-dimensional power Doppler ultrasound better than two-dimensional power Doppler? Reply
    Fishman, DA
    Cohen, L
    GYNECOLOGIC ONCOLOGY, 2002, 84 (02) : 353 - 353
  • [40] Two-dimensional and colour doppler contrast echocardiography of the right and left heart with the ultrasound contrast medium BY963 after intravenous a administration in conscious dogs
    Bubenheimer, P.
    Beller, K.D.
    Schaffer, P.
    European Journal of Ultrasound, 1995, 2 (04):