Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis

被引:2
|
作者
Finn, Avni P. [1 ]
Vajzovic, Lejla [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
来源
关键词
LENS GLIDE;
D O I
10.3928/23258160-20180129-08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: As an increasing number of vitreoretinal surgeons are implanting retinal prosthesis devices, the need to share surgical techniques to ease implantation in challenging scenarios grows. The authors share a technique to aide in overcoming a challenge associated with uveal prolapse in a patient undergoing Argus II retinal prosthesis (Second Sight Medical Products, Sylmar, CA) implantation. PATIENTS AND METHODS: A surgical technique is discussed and demonstrated using a video (Video available at www.healio.com/OSLIRetina). RESULTS: A Sheets glide-assisted technique was used to successfully place the electrode array in the vitreous cavity. CONCLUSION: The Sheets glide may be a useful tool in aiding the retinal surgeon to successfully and easily place the electrode array of the Argus II retinal prosthesis.
引用
收藏
页码:132 / 133
页数:2
相关论文
共 50 条
  • [31] Retinotopic to Spatiotopic Mapping in Blind Patients Implanted With the Argus II Retinal Prosthesis
    Caspi, Avi
    Roy, Arup
    Dorn, Jessy D.
    Greenberg, Robert J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (01) : 119 - 127
  • [32] The cost-effectiveness of the Argus II retinal prosthesis in Retinitis Pigmentosa patients
    Vaidya, Anil
    Borgonovi, Elio
    Taylor, Rod S.
    Sahel, Jose-Alain
    Rizzo, Stanislao
    Stanga, Paulo Eduardo
    Kukreja, Amit
    Walter, Peter
    BMC OPHTHALMOLOGY, 2014, 14
  • [33] The use of Argus® II Retinal Prosthesis to Identify Common Objects in Blind Subjects with Outer Retinal Dystrophies
    Luo, Yvonne Hsu-Lin
    Zhong, Joe
    Merlini, Francesco
    Anaflous, Fatima
    Arsiero, Maura
    Stanga, Paulo E.
    Da Cruz, Lyndon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [34] Argus® II Retinal Prosthesis System safety profile in post-market patients
    Greenberg, Robert
    Walter, Peter
    Augustin, Albert
    Kirchhof, Bernd
    daCruz, Lyndon
    Schimitzek, Hannah
    Roessler, Gernot
    Rizzo, Stanislao
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [35] Visual BOLD response in late-blind subjects with Argus II retinal prosthesis
    Castaldi, Elisa
    Cicchini, Guido Marco
    Cinelli, Laura
    Biagi, Laura
    Rizzo, Stanislao
    Morrone, Maria Concetta
    PERCEPTION, 2016, 45 : 181 - 181
  • [36] First Simultaneous Explantation and Re-Implantation of an Argus II Retinal Prosthesis System
    Seuthe, Anna-Maria
    Haus, Arno
    Januschowski, Kai
    Szurman, Peter
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2019, 50 (07): : 462 - 465
  • [37] Recent Results from Second Sight's Argus® II Retinal Prosthesis Study
    Humayun, Mark
    daCruz, Lyndon
    Dagnelie, Gislin
    Stanga, Paulo
    Ho, Allen
    Greenberg, Robert
    Birch, David
    Duncan, Jacque
    Sahel, Jose
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] Argus II Retinal Prosthesis Implantation in a Patient With a History Of Strabismus Surgery: A Surgical Technique
    Narala, Ramsudha
    Humayun, Mark S.
    Ameri, Hossein
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2019, 50 (02): : 116 - 119
  • [39] Synergistic Visual Gains Attained using Argus II Retinal Prosthesis with OrCam MyEye
    Finn, Avni P.
    Tripp, Fay
    Whitaker, Diane
    Vajzovic, Lejla
    OPHTHALMOLOGY RETINA, 2018, 2 (04): : 382 - 384
  • [40] Development of a Mountable Filtering System for Enhancing Visual Perception of the Argus II Retinal Prosthesis
    Gonzalez, Alex
    Aguilar, Mariela
    Rowaan, Cornelis J.
    Lam, Byron L.
    Gregori, Ninel Z.
    Zann, Kasey
    Parel, Jean-Marie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)