Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis

被引:2
|
作者
Finn, Avni P. [1 ]
Vajzovic, Lejla [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
来源
关键词
LENS GLIDE;
D O I
10.3928/23258160-20180129-08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: As an increasing number of vitreoretinal surgeons are implanting retinal prosthesis devices, the need to share surgical techniques to ease implantation in challenging scenarios grows. The authors share a technique to aide in overcoming a challenge associated with uveal prolapse in a patient undergoing Argus II retinal prosthesis (Second Sight Medical Products, Sylmar, CA) implantation. PATIENTS AND METHODS: A surgical technique is discussed and demonstrated using a video (Video available at www.healio.com/OSLIRetina). RESULTS: A Sheets glide-assisted technique was used to successfully place the electrode array in the vitreous cavity. CONCLUSION: The Sheets glide may be a useful tool in aiding the retinal surgeon to successfully and easily place the electrode array of the Argus II retinal prosthesis.
引用
收藏
页码:132 / 133
页数:2
相关论文
共 50 条
  • [21] Visual field changes following implantation of the Argus II retinal prosthesis
    Stanislao Rizzo
    Claudia Belting
    Laura Cinelli
    Luca Allegrini
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 323 - 325
  • [22] Implantation of the Argus II Retinal Prosthesis in an Eye With Short Axial Length
    Montezuma, Sandra R.
    Tang, Peter H.
    van Kuijk, Frederik J. G. M.
    Drayna, Paul
    Koozekanani, Dara D.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (04): : 369 - 371
  • [23] OCT Characteristics Among Subjects Implanted with the Argus II Retinal Prosthesis System; the Argus II OCT Study Group
    Hoeppner, Catherine
    Callaway, Natalia F.
    Gregori, Ninel
    Lam, Byron L.
    Ameri, Hossein
    Augustin, Albert J.
    Ho, Allen
    Iezzi, Raymond
    Jayasundera, Thiran
    Kokame, Gregg
    Lim, Jennifer I.
    Szurman, Peter
    Vajzovic, Lejla
    Wiedemann, Peter M. H.
    Yan, Jiong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] Long term positional stability of the Argus II retinal prosthesis epiretinal implant
    Nimra Ghani
    Jahnvi Bansal
    Abhishek Naidu
    Khurram M. Chaudhary
    BMC Ophthalmology, 23
  • [25] Seeing Heat: Efficacy of a Thermal Camera in the Argus II Retinal Prosthesis System
    Bajaj, Rohan
    Sadeghi, Roksana
    Barry, Michael P.
    Gibson, Paul
    Caspi, Avi
    Roy, Arup
    Dagnelie, Gislin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [26] Optical coherence tomography imaging in the management of the Argus II retinal prosthesis system
    Parmeggiani, Francesco
    De Nadai, Katia
    Piovan, Angela
    Binotto, Andrea
    Zamengo, Sara
    Chizzolini, Marzio
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (01) : E16 - E21
  • [27] Visual BOLD Response in Late Blind Subjects with Argus II Retinal Prosthesis
    Castaldi, E.
    Cicchini, G. M.
    Cinelli, L.
    Biagi, L.
    Rizzo, S.
    Morrone, M. C.
    PLOS BIOLOGY, 2016, 14 (10):
  • [28] Intraoperative OCT imaging of the Argus II retinal prosthesis and its clinical significance
    Falkner-Radler, C.
    Lytvynchuk, L.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 39 - 39
  • [29] The cost-effectiveness of the Argus II retinal prosthesis in Retinitis Pigmentosa patients
    Anil Vaidya
    Elio Borgonovi
    Rod S Taylor
    José-Alain Sahel
    Stanislao Rizzo
    Paulo Eduardo Stanga
    Amit Kukreja
    Peter Walter
    BMC Ophthalmology, 14
  • [30] Long term positional stability of the Argus II retinal prosthesis epiretinal implant
    Ghani, Nimra
    Bansal, Jahnvi
    Naidu, Abhishek
    Chaudhary, Khurram M.
    BMC OPHTHALMOLOGY, 2023, 23 (01)