A Flow Injection Chemiluminescence Method for the Determination of Retinol in Pharmaceutical Formulations by Using Luminol-Diperiodatoargentate(III) Reaction

被引:2
|
作者
Ambar [1 ]
Asghar, Muhammad [1 ]
Ameen, Fuad [2 ]
Al-Nadhari, Saleh [3 ]
Waseem, Amir [4 ]
Yaqoob, Mohammad [1 ]
Alarfaj, Abdullah A. [5 ]
Nabi, Abdul [1 ]
机构
[1] Univ Balochistan, Dept Chem, Sariab Rd, Quetta 87300, Pakistan
[2] King Saud Univ, Fac Sci, Dept Bot & Microbiol, Riyadh 11451, Saudi Arabia
[3] King Saud Univ, Coll Food & Agr Sci, Plant Protect Dept, Riyadh 11451, Saudi Arabia
[4] Quaid I Azam Univ, Dept Chem, Islamabad 45320, Pakistan
[5] King Saud Univ, Coll Sci, Dept Bot & Microbiol, Riyadh 11451, Saudi Arabia
关键词
vitamin A; analytical applications; CL mechanism; sensitive method; liquid-liquid extraction; VITAMIN-A-DEFICIENCY; ALPHA-TOCOPHEROL; LIQUID-CHROMATOGRAPHY; FLUORESCENCE; COMPLEXES;
D O I
10.3177/jnsv.66.10
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
In this paper, a chemiluminescence (CL) method is proposed for retinol determination by combining flow injection (FI) methodology. The CL reaction is based on the oxidation of luminol by diperiodatoargentate (III) (DPA) in the presence of retinol. Under the optimum conditions, the relative CL intensity was linear to the concentration of retinol over the range 5.0X10(-3)-14 mg L-1 (y=347.26x+2.5944, R-2 =0.9999, n=8) with limit of detection (LOD) of 1.5 x 10(-3) mg L-1 (S/N= 3) and limit of quantification (LOQ) of 5.0X 10(-3) mg L-1 (S/N=10). The relative standard deviation (RSD) was from 1.04-3.4% over the range studied and injection throughputs of 150 h(-1). The method was satisfactorily applied to retinol in pharmaceutical formulation samples. The samples were saponified and extracted with liquid-liquid extraction using ether as an extractant. The possible CL mechanism is supported by CL and UV-visible spectrophotometric studies.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 50 条
  • [41] A Metal Enhanced Flow-Injection Chemiluminescence Method for the Rapid Determination of Norfloxacin in Pharmaceutical Formulations and Serum Sample
    Kamruzzaman, Mohammad
    Ferdous, Taslima
    Alam, Al-Mahmnur
    Lee, Sang Hak
    Kim, So Yeun
    Kim, Young Ho
    Kim, Sung Hong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (02) : 639 - 644
  • [42] Determination of carbaryl by flow injection with luminol chemiluminescence inhibition detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    Siddiqui, Masood Ahmed
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (12) : 825 - 832
  • [43] Flow injection chemiluminescence method for the determination of phenol with N-bromosuccinimide-luminol system
    Du, LY
    Ji, NN
    Wang, SH
    Zhuang, HS
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1943 - 1946
  • [44] A Novel Flow Injection Chemiluminescence Method with Ferricyanide and Luminol for the Determination of Ractopamine in Biological Samples
    Feng Ting
    Hu Yu-fei
    Li Gong-ke
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (01) : 74 - 77
  • [45] Flow Injection Chemiluminescence Method for Nalbuphine Hydrochloride in Pharmaceutical Formulations Using Tris(2,2′-bipyridyl)ruthenium(II) Chloride-diperiodatocuprate(III) Reaction
    Ahmed, Khan
    Muhammad, Asghar
    Mohammed, Yaqoob
    Masood, Ahmed Siddiqui
    Samar, Ali
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2021, 37 (03) : 629 - 638
  • [46] Flow Injection Chemiluminescence Method for Nalbuphine Hydrochloride in Pharmaceutical Formulations Using Tris(2,2′-bipyridyl)ruthenium(II) Chloride-diperiodatocuprate(III) Reaction
    Khan Ahmed
    Asghar Muhammad
    Yaqoob Mohammed
    Ahmed Siddiqui Masood
    Ali Samar
    Chemical Research in Chinese Universities, 2021, 37 : 629 - 638
  • [47] Flow-Injection Determination of Ornidazole by Chemiluminescence Detection Basedon a Luminol-Ferricyanide Reaction
    Yi Lv
    Zhujun Zhang
    Deyong He
    Yufei Hu
    Analytical Sciences, 2003, 19 : 625 - 626
  • [48] Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
    Wang, ZP
    Zhang, ZJ
    Zhang, XO
    Fu, ZF
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 1 - 7
  • [49] Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction
    Lv, Y
    Zhang, ZJ
    He, DY
    Hu, YF
    ANALYTICAL SCIENCES, 2003, 19 (04) : 625 - 627
  • [50] Sensitive determination of captopril by flow injection analysis with chemiluminescence detection based on the enhancement of the luminol reaction
    Economou, A
    Themelis, DG
    Theodoridis, G
    Tzanavaras, PD
    ANALYTICA CHIMICA ACTA, 2002, 463 (02) : 249 - 255