A Novel Flow Injection Chemiluminescence Method with Ferricyanide and Luminol for the Determination of Ractopamine in Biological Samples

被引:1
|
作者
Feng Ting [1 ]
Hu Yu-fei [1 ]
Li Gong-ke [1 ]
机构
[1] Sun Yat Sen Univ, Sch Chem & Chem Engn, Guangzhou 510275, Guangdong, Peoples R China
关键词
Chemiluminescence; Flow injection; Ractopamine; Luminal; Ferricyanide; Biological samples; TANDEM MASS-SPECTROMETRY; ISOTOPE-DILUTION; CLENBUTEROL; AGONISTS; TISSUE; URINE; LIVER;
D O I
10.3964/j.issn.1000-0593(2012)01-0074-04
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A novel chemiluminescence method coupled with flow injection technique for the determination of ractopamine was developed. It was based on the enhancement of the chemiluminescence by ractopamine derived from the chemiluminescence reaction between luminol and ferricyanide in sodium hydroxide medium. The linear calibration range of the chemiluminescence intensity with respect to the ractopamine concentration covers from 4. 0 X10(-9)similar to 8. 0x 10(-7) g . mL(-1). The relative standard deviation for ractopamine is 5. 6% (n=11), and the detection limit is 2. 5 X 10(-9) g . mL(-1). The method was firstly applied to the determination of ractopamine in biological samples with satisfactory results. The recovery was between 69. 3% and 101. 3%.
引用
收藏
页码:74 / 77
页数:4
相关论文
共 15 条
  • [1] Determination of clenbuterol, ractopamine and zilpaterol in liver and urine by liquid chromatography tandem mass spectrometry
    Blanca, J
    Muñoz, P
    Morgado, M
    Méndez, N
    Aranda, A
    Reuvers, T
    Hooghuis, H
    [J]. ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) : 199 - 205
  • [2] Gao YiMing Gao YiMing, 2009, Chinese Journal of Animal Health Inspection, V26, P37
  • [3] Determination of ractopamine and clenbuterol in feeds by gas chromatography-mass spectrometry
    He, Limin
    Su, Yijuan
    Zeng, Zhenling
    Liu, Yahong
    Huang, Xianhui
    [J]. ANIMAL FEED SCIENCE AND TECHNOLOGY, 2007, 132 (3-4) : 316 - 323
  • [4] KONG LY, 2006, GUANGDONG FEED, V8, P31
  • [5] Kuiper HA, 1998, J ANIM SCI, V76, P195
  • [6] Simultaneous determination of clenbuterol, salbutamol and ractopamine in milk by reversed-phase liquid chromatography tandem mass spectrometry with isotope dilution
    Li, Cun
    Wu, Yin-Liang
    Yang, Ting
    Zhang, Yan
    Huang-Fu, Wei-Guo
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (50) : 7873 - 7877
  • [7] Generic sample preparation combined with high-resolution liquid chromatography-time-of-flight mass spectrometry for unification of urine screening in doping-control laboratories
    Peters, R. J. B.
    Oosterink, J. E.
    Stolker, A. A. M.
    Georgakopoulos, C.
    Nielen, M. W. F.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2583 - 2598
  • [8] Recent applications of surface plasmon resonance biosensors for analyzing residues and contaminants in food
    Petz, Michael
    [J]. MONATSHEFTE FUR CHEMIE, 2009, 140 (08): : 953 - 964
  • [9] An electrochemical immunosensor based on agarose hydrogel films for rapid determination of ractopamine
    Shen, Li
    He, Pingli
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (04) : 657 - 662
  • [10] [孙建文 SUN Jianwen], 2008, [分析试验室, Chinese Journal of Analysis Laboratory], V27, P90