Evaluation of commercial immunoassays for the detection of estrogens in water by comparison with high-performance liquid chromatography tandem mass spectrometry HPLC-MS/MS (QqQ)

被引:35
|
作者
Farre, Marinella
Brix, Rikke
Kuster, Marina
Rubio, Fernando
Goda, Yasuhiro
de Alda, Mara J. Lopez
Barcelo, Damia
机构
[1] CSIC, IIQAB, Dept Environm Chem, ES-08034 Barcelona, Spain
[2] UAB, Dept Analyt Chem, Sensors & Biosensors Grp, Bellaterra 08193, Cerdanyola Vall, Spain
[3] Abraxis, Warminster, PA 18974 USA
[4] Japan EnviroChem Ltd, Yodogawa Ku, Osaka 5320024, Japan
关键词
immunoassay; ELISA; estrogens; LC-MS/MS;
D O I
10.1007/s00216-006-0562-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work four different commercially available enzyme-linked immunosorbent assays (ELISA) (from Japan EnviroChemicals, Ltd., Tokyo, Japan) were evaluated in terms of performance for the rapid screening of estrogens in different water matrices, including natural and spiked samples from urban wastewater, river water and ground water. All four test kits are based on monoclonal antibodies. The compounds detected by these immunoassays are (1) 17-beta-estradiol, (2) estrone, (3) 17-alpha-ethynyl estradiol and (4) estrogens in general, with high recognition properties for 17-beta-estradiol, estrone and estriol. Standards were prepared in water containing 10% (v/v) methanol. The IC (50) (corresponding to the 50% of the effective concentration) values, the dynamic ranges, and the limits of detection of the ELISA kits were 0.060-0.304 mu g/L, 0.05-5 mu g/L and 0.05 mu g/L, respectively. All samples were extracted by solid-phase extraction (SPE) beforehand, and the evaluation was carried out by comparing the results obtained by ELISA with those obtained by HPLC-MS/MS using a triple quadrupole (QqQ) instrument. In addition, two different solid-phase extraction procedures were carried out and compared. Except for moderate overestimation in the results observed with the ELISA kits in the analysis of complex wastewater samples, the results obtained using all of the tested techniques were generally in very good agreement.
引用
收藏
页码:1001 / 1011
页数:11
相关论文
共 50 条
  • [41] Implementing an immunosuppressant TDM HPLC-MS/MS platform in a clinical environment: Comparison with commercial immunoassays as key step in the performance evaluation
    Seger, Christopli
    Tentschert, Karin
    Hammerer-Lercher, Angelika
    Griesmacher, Andrea
    THERAPEUTIC DRUG MONITORING, 2007, 29 (04) : 505 - 506
  • [42] Approach for ochratoxin A fast screening in spices using clean-up tandem immunoassay columns with confirmation by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS)
    Goryacheva, I. Yu.
    De Saeger, S.
    Lobeau, M.
    Eremin, S. A.
    Barna-Vetro, I.
    Van Peteghem, C.
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 38 - 45
  • [43] Rapid Determination of Lignans in Schisandra chinensis by Supramolecular Solvent (SUPRAS)-Based Extraction and High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS)
    Fu, Lina
    Wang, Litao
    Zhang, Su
    Fu, Yujie
    ANALYTICAL LETTERS, 2024, 57 (07) : 1137 - 1149
  • [44] High performance liquid chromatography/atmospheric pressure ionization/tandem mass spectrometry (HPLC/API/MS/MS) in drug metabolism and toxicology
    Kamel, Amin
    Prakash, Chandra
    CURRENT DRUG METABOLISM, 2006, 7 (08) : 837 - 852
  • [45] Comparative Proteomics in Rice Seedlings to Characterize the Resistance to Cadmium Stress by High-Performance Liquid Chromatography - Tandem Mass Spectrometry (HPLC-MS/MS) with Isobaric Tag for Relative and Absolute Quantitation (iTRAQ)
    Liu, Sanxiong
    Li, Yongchao
    Liu, Licheng
    Min, Jun
    Liu, Wenqiang
    Li, Xiaoxiang
    Pan, Xiaowu
    Lu, Xiangyang
    Deng, Qiyun
    ANALYTICAL LETTERS, 2020, 53 (05) : 807 - 820
  • [46] Development and Validation of a High-Performance Liquid Chromatography with Tandem Mass Spectrometry (HPLC-MS/MS) Method for Quantification of Major Molnupiravir Metabolite (β-D-N4-hydroxycytidine) in Human Plasma
    Komarov, Timofey
    Karnakova, Polina
    Archakova, Olga
    Shchelgacheva, Dana
    Bagaeva, Natalia
    Popova, Mariia
    Karpova, Polina
    Zaslavskaya, Kira
    Bely, Petr
    Shohin, Igor
    BIOMEDICINES, 2023, 11 (09)
  • [47] Quantification of Amino Acids in Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Panaskar, Shrimant N.
    Singh, Susheel K.
    CHROMATOGRAPHIA, 2023, 86 (07) : 567 - 572
  • [48] CONFIRMATORY ANALYSIS FOR DRUGS OF ABUSE IN PLASMA BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC/MS/MS)
    Bagnati, M.
    Vidali, M.
    Albertario, M.
    Scarano, D.
    Atzeni, N.
    Luna, C.
    Bellomo, G.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S802 - S802
  • [49] High performance liquid chromatography-mass spectrometry/mass spectrometry (HPLC-MS/MS) analysis of transmembrane transport characteristics of nuciferine in Caco-2 cells
    Dong, Xiaochen
    Zhu, Shengnan
    Dong, Zonghua
    Ye, Luting
    Liu, Mingqi
    Zhao, Jin
    Ge, Jian
    Journal of Biotech Research, 2022, 12 : 144 - 151
  • [50] Determination of Pesticides in Apples by High-Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS) with High-Resolution Multiple Reaction Monitoring
    Tu, Feng-Qin
    Yang, Ming
    ANALYTICAL LETTERS, 2022, 55 (03) : 438 - 448