Evaluation of commercial immunoassays for the detection of estrogens in water by comparison with high-performance liquid chromatography tandem mass spectrometry HPLC-MS/MS (QqQ)

被引:35
|
作者
Farre, Marinella
Brix, Rikke
Kuster, Marina
Rubio, Fernando
Goda, Yasuhiro
de Alda, Mara J. Lopez
Barcelo, Damia
机构
[1] CSIC, IIQAB, Dept Environm Chem, ES-08034 Barcelona, Spain
[2] UAB, Dept Analyt Chem, Sensors & Biosensors Grp, Bellaterra 08193, Cerdanyola Vall, Spain
[3] Abraxis, Warminster, PA 18974 USA
[4] Japan EnviroChem Ltd, Yodogawa Ku, Osaka 5320024, Japan
关键词
immunoassay; ELISA; estrogens; LC-MS/MS;
D O I
10.1007/s00216-006-0562-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work four different commercially available enzyme-linked immunosorbent assays (ELISA) (from Japan EnviroChemicals, Ltd., Tokyo, Japan) were evaluated in terms of performance for the rapid screening of estrogens in different water matrices, including natural and spiked samples from urban wastewater, river water and ground water. All four test kits are based on monoclonal antibodies. The compounds detected by these immunoassays are (1) 17-beta-estradiol, (2) estrone, (3) 17-alpha-ethynyl estradiol and (4) estrogens in general, with high recognition properties for 17-beta-estradiol, estrone and estriol. Standards were prepared in water containing 10% (v/v) methanol. The IC (50) (corresponding to the 50% of the effective concentration) values, the dynamic ranges, and the limits of detection of the ELISA kits were 0.060-0.304 mu g/L, 0.05-5 mu g/L and 0.05 mu g/L, respectively. All samples were extracted by solid-phase extraction (SPE) beforehand, and the evaluation was carried out by comparing the results obtained by ELISA with those obtained by HPLC-MS/MS using a triple quadrupole (QqQ) instrument. In addition, two different solid-phase extraction procedures were carried out and compared. Except for moderate overestimation in the results observed with the ELISA kits in the analysis of complex wastewater samples, the results obtained using all of the tested techniques were generally in very good agreement.
引用
收藏
页码:1001 / 1011
页数:11
相关论文
共 50 条
  • [21] DETERMINATION OF LEVODOPA IN HUMAN PLASMA BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (HPLC-MS/MS): APPLICATION TO A BIOEQUIVALENCE STUDY
    Martins, Heliana F.
    Pinto, Douglas P.
    Nascimento, Viviane de A.
    Marques, Marlice A. S.
    Amendoeira, Fabio C.
    QUIMICA NOVA, 2013, 36 (01): : 171 - U410
  • [22] Identification of Polyphenol Glucuronide Conjugates in Glechoma hederacea var. longituba Hot Water Extracts by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
    Cho, Kun
    Choi, Yoon-Ji
    Ahn, Yeong Hee
    MOLECULES, 2020, 25 (20):
  • [23] Rapid Quantification of Soyasaponins I and βg in Italian Lentils by High-Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometry (MS/MS)
    Donat, Pilar Vila
    Caprioli, Giovanni
    Conti, Paolo
    Maggi, Filippo
    Ricciutelli, Massimo
    Torregiani, Elisabetta
    Vittori, Sauro
    Sagratini, Gianni
    FOOD ANALYTICAL METHODS, 2014, 7 (05) : 1024 - 1031
  • [24] Rapid Quantification of Soyasaponins I and βg in Italian Lentils by High-Performance Liquid Chromatography (HPLC)–Tandem Mass Spectrometry (MS/MS)
    Pilar Vila Donat
    Giovanni Caprioli
    Paolo Conti
    Filippo Maggi
    Massimo Ricciutelli
    Elisabetta Torregiani
    Sauro Vittori
    Gianni Sagratini
    Food Analytical Methods, 2014, 7 : 1024 - 1031
  • [25] Validation of a rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay for the simultaneous determination of existing and new antiretroviral compounds
    Else, Laura
    Watson, Victoria
    Tjia, John
    Hughes, Andrew
    Siccardi, Marco
    Khoo, Saye
    Back, David
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1455 - 1465
  • [26] Simple Quantitative Determination of Potent Thiols at Ultratrace Levels in Wine by Derivatization and High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) Analysis
    Capone, Dimitra L.
    Ristic, Renata
    Pardon, Kevin H.
    Jeffery, David W.
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1226 - 1231
  • [27] Immunosuppressive drug monitoring in renal transplantation: comparison between Elecsys® immunoassays and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Robitaille, Robert
    Gingras, Marie-Eve
    Cossette, Chantal
    CLINICAL BIOCHEMISTRY, 2016, 49 (18)
  • [28] Determination of two progestinmetabolites (17α-hydroxypregnanolone and pregnanediol) and different classes of steroids (androgens, estrogens, corticosteroids, progestins) in rivers and wastewaters by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)
    Zhang, Kun
    Fent, Karl
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 610 : 1164 - 1172
  • [29] Metabolomic Analysis of Amino Acid and Organic Acid Profiles in Tissue From Ovarian Cancer Patients Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS)
    Oh, Songjin
    Ji, Moongi
    Kim, Doo-Young
    Choi, Subin
    Kee, Yerim
    Woo, Sanghyeon
    Lee, Hyeon-Seong
    Choi, Byeongchan
    Park, Hyung-Jin
    Lee, Hae Nam
    Paik, Man-Jeong
    ANALYTICAL LETTERS, 2025, 58 (04) : 623 - 638
  • [30] Determination of Mycotoxins Using Hollow Fiber Dispersive Liquid-Liquid-Microextraction (HF-DLLME) Prior to High-Performance Liquid Chromatography - Tandem Mass Spectrometry (HPLC-MS/MS)