Comparative Voltammetric Analysis of Adenine and Xanthine on a Pencil Graphite Electrode in the Presence of Copper Ions

被引:0
|
作者
Navratil, Rudolf [1 ]
Pilarova, Iveta [1 ,2 ]
Jelen, Frantisek [3 ]
Trnkova, Libuse [1 ,4 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Chem, CZ-62500 Brno, Czech Republic
[2] Masaryk Univ, CEITEC MU, CZ-62500 Brno, Czech Republic
[3] Inst Biophys AS CR, Vvi, CZ-61265 Brno, Czech Republic
[4] Univ Technol, CEITEC, CZ-61600 Brno, Czech Republic
来源
关键词
Oxidation of purines; Pencil graphite electrode; Linear sweep voltammetry; Differential pulse voltammetry; Elimination voltammetry with linear scan; ADSORPTIVE STRIPPING VOLTAMMETRY; ELIMINATION VOLTAMMETRY; ANODIC VOLTAMMETRY; CARBON ELECTRODES; CYTOSINE SIGNALS; PURINE-BASES; URIC-ACID; HYPOXANTHINE; OXIDATION; DNA;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work compares voltammetric responses of adenine (Ade) and xanthine (Xan) on a pencil graphite electrode (PeGE) in the presence of copper ions. For electroanalytical monitoring linear sweep voltammetry (LSV) in connection with elimination procedure (EVLS - elimination voltammetry with linear scan), differential pulse voltammetry (DPV), and constant current potentiostatic stripping analysis (CPSA) were used. Both substances are oxidized on PeGE providing simple oxidation peaks in the absence of Cu(II) at about 0.8 V (Xan) and 1.1 V (Ade). Electrochemically produced Cu(I) ions give rise to new oxidation peaks corresponding to the oxidation of a sparingly soluble Cu(I)-purine complex at less positive potentials (similar to 0.45 V) while the former oxidation purine peaks are increased. Compared to Ade the oxidative signal of Xan is split into two peaks depending on scan rate. Peak-counterpeak EVLS signals reflect the charge transfer processes proceeding in an adsorbed state, and this fact confirms the suggested mechanism of both electrode processes. The splitting of xanthine oxidation signal was tested by means of a potential jump from -0.15 V to 0.65 V. The effect of scan rate, pH and concentration of Cu and ligands was studied in order to evaluate not only the nature of the additional Xan oxidation peak but also to optimize the best conditions for electroanalytical determination of Ade and Xan in mixtures.
引用
收藏
页码:4397 / 4408
页数:12
相关论文
共 50 条
  • [31] A disposable voltammetric sensor for the determination of diphenylamine using modified pencil graphite electrode
    Antherjanam, Santhy
    Saraswathyamma, Beena
    ANALYTICAL SCIENCES, 2024, 40 (01) : 163 - 174
  • [32] Voltammetric determination of fenitrothion based on pencil graphite electrode modified with poly(Purpald®)
    Mert Soysal
    Chemical Papers, 2019, 73 : 1785 - 1794
  • [33] Voltammetric analysis of naringenin at a disposable pencil graphite electrode - application to polyphenol content determination in citrus juice
    David, Iulia Gabriela
    Litescu, Simona Carmen
    Popa, Dana Elena
    Buleandra, Mihaela
    Iordache, Lorelei
    Albu, Camelia
    Alecu, Andreia
    Penu, Ramona Liliana
    ANALYTICAL METHODS, 2018, 10 (48) : 5763 - 5772
  • [34] Electrochemically Inspired Copper(II) Complex on Disposable Graphite Pencil Electrode for Effective Simultaneous Detection of Hypoxanthine, Xanthine, and Uric Acid
    Odewunmi, Nurudeen A.
    Kawde, Abdel-Nasser
    Ibrahim, Mohamed
    ELECTROANALYSIS, 2018, 30 (10) : 2311 - 2320
  • [35] Carboxylated-Graphene Decorated Pencil Graphite Electrode as a Platform for Voltammetric Detection of DNA
    Zor, Erhan
    Eksin, Ece
    Findik, Mukerrem
    Bingol, Haluk
    Erdem, Arzum
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) : B723 - B729
  • [36] Immobilization and voltammetric detection of human interleukine-2 gene on the pencil graphite electrode
    Hejazi, M. S.
    Alipour, E.
    Pournaghi-Azar, M. H.
    TALANTA, 2007, 71 (04) : 1734 - 1740
  • [37] Differential pulse voltammetric determination of acyclovir in pharmaceutical preparations using a pencil graphite electrode
    Dilgin, Didem Giray
    Karakaya, Serkan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 570 - 576
  • [38] Voltammetric Determination of Oxybutynin Hydrochloride Utilizing Pencil Graphite Electrode Decorated with Gold Nanoparticles
    Arafa, Reham M.
    Mahmoud, Amr M.
    Eltanany, Basma M.
    Galal, Maha M.
    ELECTROANALYSIS, 2023, 35 (04)
  • [39] Glycine-modified Pencil Graphite Electrode as a Sensor for Caffeine Determination: A Voltammetric Study
    Korkmaz, Seyma
    Bosnali, Wael
    Sharifi, Hafizullah
    Mulazimoglu, Ibrahim Ender
    Mulazimoglu, Aysen Demir
    CURRENT ANALYTICAL CHEMISTRY, 2024,
  • [40] Development of a voltammetric method for the determination of rapamycin in pharmaceutical samples at pretreated pencil graphite electrode
    Karaboduk, Kuddusi
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (09) : 1722 - 1730