Comparative Voltammetric Analysis of Adenine and Xanthine on a Pencil Graphite Electrode in the Presence of Copper Ions

被引:0
|
作者
Navratil, Rudolf [1 ]
Pilarova, Iveta [1 ,2 ]
Jelen, Frantisek [3 ]
Trnkova, Libuse [1 ,4 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Chem, CZ-62500 Brno, Czech Republic
[2] Masaryk Univ, CEITEC MU, CZ-62500 Brno, Czech Republic
[3] Inst Biophys AS CR, Vvi, CZ-61265 Brno, Czech Republic
[4] Univ Technol, CEITEC, CZ-61600 Brno, Czech Republic
来源
关键词
Oxidation of purines; Pencil graphite electrode; Linear sweep voltammetry; Differential pulse voltammetry; Elimination voltammetry with linear scan; ADSORPTIVE STRIPPING VOLTAMMETRY; ELIMINATION VOLTAMMETRY; ANODIC VOLTAMMETRY; CARBON ELECTRODES; CYTOSINE SIGNALS; PURINE-BASES; URIC-ACID; HYPOXANTHINE; OXIDATION; DNA;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work compares voltammetric responses of adenine (Ade) and xanthine (Xan) on a pencil graphite electrode (PeGE) in the presence of copper ions. For electroanalytical monitoring linear sweep voltammetry (LSV) in connection with elimination procedure (EVLS - elimination voltammetry with linear scan), differential pulse voltammetry (DPV), and constant current potentiostatic stripping analysis (CPSA) were used. Both substances are oxidized on PeGE providing simple oxidation peaks in the absence of Cu(II) at about 0.8 V (Xan) and 1.1 V (Ade). Electrochemically produced Cu(I) ions give rise to new oxidation peaks corresponding to the oxidation of a sparingly soluble Cu(I)-purine complex at less positive potentials (similar to 0.45 V) while the former oxidation purine peaks are increased. Compared to Ade the oxidative signal of Xan is split into two peaks depending on scan rate. Peak-counterpeak EVLS signals reflect the charge transfer processes proceeding in an adsorbed state, and this fact confirms the suggested mechanism of both electrode processes. The splitting of xanthine oxidation signal was tested by means of a potential jump from -0.15 V to 0.65 V. The effect of scan rate, pH and concentration of Cu and ligands was studied in order to evaluate not only the nature of the additional Xan oxidation peak but also to optimize the best conditions for electroanalytical determination of Ade and Xan in mixtures.
引用
收藏
页码:4397 / 4408
页数:12
相关论文
共 50 条
  • [21] Piroxicam voltammetric determination by ultra low cost pencil graphite electrode
    Lopes de Macedo, Isaac Yves
    Alecrim, Morgana Fernandes
    Oliveira Neto, Jeronimo Raimundo
    Sapateiro Torres, Ieda Maria
    Thomaz, Douglas Vieira
    Gil, Eric de Souza
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 56
  • [22] Anodic stripping voltammetric determination of vardenafil hydrochloride at pencil graphite electrode
    Aydin, Zehra Yazar
    Yaman, Yesim Tugce
    Yasacan, Merve
    Cirak, Tamer
    Abaci, Serdar
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (04) : 803 - 810
  • [23] Voltammetric Determination of Tannic Acid in Beverages using Pencil Graphite Electrode
    Vu, Dai Long
    Ertek, Bensu
    Dilgin, Yusuf
    Cervenka, Libor
    CZECH JOURNAL OF FOOD SCIENCES, 2015, 33 (01) : 72 - 76
  • [24] Anodic stripping voltammetric determination of vardenafil hydrochloride at pencil graphite electrode
    Zehra Yazar Aydın
    Yesim Tugce Yaman
    Merve Yaşacan
    Tamer Çırak
    Serdar Abacı
    Journal of the Iranian Chemical Society, 2017, 14 : 803 - 810
  • [25] Voltammetric determination of diazepam using a bismuth modified pencil graphite electrode
    Dehghanzade, Mahsa
    Alipour, Esmaeel
    ANALYTICAL METHODS, 2016, 8 (09) : 1995 - 2004
  • [26] Cystine coupled tyrosine modified disposable pencil graphite electrode for the simultaneous analysis of adenine and thymine
    Jyothi, Sreelekshmi Premchanth
    Vinod, Devika
    Chandran, Devu
    Sadanandan, Sandhya
    Rajamani, Rejithamol
    CHEMICAL PAPERS, 2025, 79 (02) : 897 - 913
  • [27] Voltammetric Determination of Pyridoxine in Pharmaceutical Samples Using Phosphorus-Doped Copper Oxide Pencil Graphite Electrode
    Acikalin, Merve Yalcin
    Dokur, Ebrar
    Uruc, Selen
    Gorduk, Ozge
    Sahin, Yucel
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (11)
  • [28] Voltammetric determination of fenitrothion based on pencil graphite electrode modified with poly(Purpald®)
    Soysal, Mert
    CHEMICAL PAPERS, 2019, 73 (07): : 1785 - 1794
  • [29] A disposable voltammetric sensor for the determination of diphenylamine using modified pencil graphite electrode
    Santhy Antherjanam
    Beena Saraswathyamma
    Analytical Sciences, 2024, 40 : 163 - 174
  • [30] Polymer lead pencil graphite as electrode material: Voltammetric, XPS and Raman study
    Navratil, Rudolf
    Kotzianova, Adela
    Halouzka, Vladimir
    Opletal, Tomas
    Triskova, Iveta
    Trnkova, Libuse
    Hrbac, Jan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 783 : 152 - 160