Comparison Between a Laser Micrometer and a Touch Trigger Probe for Workpiece Measurement on a CNC Lathe

被引:11
|
作者
Valino, G. [1 ]
Suarez, C. M. [1 ]
Rico, J. C. [1 ]
Alvarez, B. J. [1 ]
Blanco, D. [1 ]
机构
[1] Univ Oviedo, Dep Construct & Mfg Engn, Gijon 33203, Spain
关键词
On-machine measurement (OMM); Laser Micrometer; Touch Trigger Probe; Turning;
D O I
10.4028/www.scientific.net/AMR.498.49
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The current requirements for an efficient dimensional inspection of manufactured parts have lead to development of different in process and on-machine measurement (OMM) techniques. Touch trigger probes (TTP) are the most common technologies utilized, inspired on contact probes used on coordinate measuring machines (CMMs). The on-machine accuracy of TTPs depends upon precision of the tool-machine control as well as upon the procedure for TTP presetting. Taking this into account, a different OMM technique is considered in this work, which consists on a laser micrometer (LM) that is commonly used for in-process measurement of continuous products. The behaviour of TTP and LM is analysed and discussed in terms of repeatability and reproducibility. Results obtained by both techniques are compared each other by measuring a cylindrical workpiece and by checking the results with those obtained on a CMM.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [41] Optical frequency measurement comparison using fiber laser combs between NIMT and CMS
    Chanthawong, N.
    Buajarern, J.
    Peng, J. L.
    Ting, W. J.
    SIAM PHYSICS CONGRESS 2018 (SPC2018): A CREATIVE PATH TO SUSTAINABLE INNOVATION, 2018, 1144
  • [42] Multi-kilowatt cw laser power measurement comparison between national standards
    Rogers, Kyle
    Williams, Paul
    Pastuschek, Marcel
    Lecher, Holger
    Kueck, Stefan
    Lopez, Marco
    Lehman, John
    METROLOGIA, 2024, 61 (02)
  • [43] Optical Frequency Measurement Comparison Using Fiber Laser Combs Between CMS and NMIJ
    Peng, Jin-Long
    Shu, Ren-Huei
    Liu, Tze-An
    Inaba, Hajime
    Hosaka, Kazumoto
    Yasuda, Masami
    Akamatsu, Daisuke
    Onae, Atsushi
    Hong, Feng-Lei
    2013 JOINT EUROPEAN FREQUENCY AND TIME FORUM & INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFC), 2013, : 391 - +
  • [44] Comparison of Langmuir probe and laser Thomson scattering methods in the electron temperature measurement in divertor simulator MAP-II
    Okamoto, A.
    Kado, S.
    Iida, Y.
    Tanaka, S.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2006, 46 (5-6) : 416 - 421
  • [45] Surface transfer impedance measurement: A comparison between current probe and pull-on braid methods for coaxial cables
    Morriello, A
    Benson, TM
    Duffy, AP
    Cheng, CF
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1998, 40 (01) : 69 - 76
  • [46] Middle ear muscle reflex measurement in neonates: Comparison between 1000 Hz and 226 Hz probe tones
    de Lyra-Silva, Kilza Arruda
    Gandolfi Sanches, Seisse Gabriela
    Neves-Lobo, Ivone Ferreira
    Ibidi, Silvia Maria
    Mamede Carvallo, Renata Mota
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2015, 79 (09) : 1510 - 1515
  • [47] Assessment of liver stiffness measurement in patients with chronic liver disease: Comparison between M and XL probe of FibroScan
    Bansal, Rinkesh Kumar
    Sharma, Praveen
    Kirnake, Vijendra
    Tyagi, Pankaj
    Bansal, Naresh
    Kumar, Ashish
    Singla, Vikas
    Shah, Vinit Sanjay
    Arora, Anil
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 261 - 261
  • [48] Electron Density Measurement in Space Plasma, Comparison between Two Techniques: Sounder by Relaxation and Mutual Impedance Probe
    Rauch, J. L.
    Henri, P.
    Lebretoun, J. P.
    Vallieres, X.
    Le Duff, O.
    Colin, F.
    Lagoutte, D.
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 495 - 495
  • [49] Diagnosis of liver fibrosis and cirrhosis using liver stiffness measurement: Comparison between M and XL probe of FibroScan®
    de Ledinghen, Victor
    Wong, Vincent Wai-Sun
    Vergniol, Julien
    Wong, Grace Lai-Hung
    Foucher, Juliette
    Chu, Shirley Ho-Ting
    Le Bail, Brigitte
    Choi, Paul Cheung-Lung
    Chermak, Faiza
    Yiu, Karen Kar-Lum
    Merrouche, Wassil
    Chan, Henry Lik-Yuen
    JOURNAL OF HEPATOLOGY, 2012, 56 (04) : 833 - 839
  • [50] Comparison between X-ray Stereoscopy and Laser Doppler Vibrometry for Motion Measurement in Biomechanics
    Salih, Wasil H. M.
    Buytaert, Jan A. N.
    Dirckx, Joris J. J.
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES & SYSTEMS2 (OPTIMESS2012), 2013, : 359 - 368