Comparison Between a Laser Micrometer and a Touch Trigger Probe for Workpiece Measurement on a CNC Lathe

被引:11
|
作者
Valino, G. [1 ]
Suarez, C. M. [1 ]
Rico, J. C. [1 ]
Alvarez, B. J. [1 ]
Blanco, D. [1 ]
机构
[1] Univ Oviedo, Dep Construct & Mfg Engn, Gijon 33203, Spain
关键词
On-machine measurement (OMM); Laser Micrometer; Touch Trigger Probe; Turning;
D O I
10.4028/www.scientific.net/AMR.498.49
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The current requirements for an efficient dimensional inspection of manufactured parts have lead to development of different in process and on-machine measurement (OMM) techniques. Touch trigger probes (TTP) are the most common technologies utilized, inspired on contact probes used on coordinate measuring machines (CMMs). The on-machine accuracy of TTPs depends upon precision of the tool-machine control as well as upon the procedure for TTP presetting. Taking this into account, a different OMM technique is considered in this work, which consists on a laser micrometer (LM) that is commonly used for in-process measurement of continuous products. The behaviour of TTP and LM is analysed and discussed in terms of repeatability and reproducibility. Results obtained by both techniques are compared each other by measuring a cylindrical workpiece and by checking the results with those obtained on a CMM.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [31] Interstitial laser thermotherapy: Comparison between bare fibre and sapphire probe
    Moller, PH
    Lindberg, L
    Henriksson, PH
    Persson, RR
    Tranberg, KG
    LASERS IN MEDICAL SCIENCE, 1995, 10 (03) : 193 - 200
  • [32] Calibration of location errors of rotary axes on five-axis machine tools by on-the-machine measurement using a touch-trigger probe
    Ibaraki, Soichi
    Iritani, Takeyuki
    Matsushita, Tetsuya
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2012, 58 : 44 - 53
  • [33] Error map construction for rotary axes on five-axis machine tools by on-the-machine measurement using a touch-trigger probe
    Ibaraki, Soichi
    Iritani, Takeyuki
    Matsushita, Tetsuya
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2013, 68 : 21 - 29
  • [34] Comparison of the quantitative analysis performance between pulsed voltage atom probe and pulsed laser atom probe
    Takahashi, J.
    Kawakami, K.
    Raabe, D.
    ULTRAMICROSCOPY, 2017, 175 : 105 - 110
  • [35] A comparison between simulation and experiment of virtual machining in CNC turning machine considering kinematic motion deviations, tool wear and workpiece deflection errors
    Thasana, Wiroj
    Chianrabutra, Srisit
    JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2019, 13 (01)
  • [36] Velocity measurement in turbulent jets. Comparison between LDV and Prandtl-probe measurement technique
    Streb, H.
    Lenze, B.
    Gaswaerme International, 1992, 41 (09): : 369 - 376
  • [37] Correlation between Incident Angle, Measurement Distance, Object Colour and the Number of Acquired Points at CNC Laser Scanning
    Vukasinovic, Nikola
    Mozina, Janez
    Duhovnik, Joze
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2012, 58 (01): : 23 - 28
  • [38] COMPARISON OF ENTHALPY PROBE AND LASER-LIGHT SCATTERING MEASUREMENT OF THERMAL PLASMA TEMPERATURES AND VELOCITIES
    FINCKE, JR
    SNYDER, SC
    SWANK, WD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (03): : 711 - 718
  • [39] A comparison between cw and pulsed laser calorimetric measurement at 1.06 μm
    Broulik, U
    Meja, P
    Steiger, B
    LASER-INDUCED DAMAGE IN OPTICAL MATERIALS: 1997, PROCEEDINGS, 1998, 3244 : 32 - 41
  • [40] Comparison of techniques between laryngeal probe and micromanipulators in microlaryngeal surgery using the carbon dioxide laser
    Handoussa, A
    ElEzz, AA
    SYDNEY '97 - XVI WORLD CONGRESS OF OTORHINOLARYNGOLOGY HEAD AND NECK SURGERY, TOMES 1 AND 2, 1996, : 589 - 592