Lightning Impulse Corona Characteristic of 1000-kV UHV Transmission Lines and Its Influences on Lightning Overvoltage Analysis Results

被引:24
|
作者
Yang, Pengcheng [1 ]
Chen, Shuiming [1 ]
He, Jinliang [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Corona cage; electromagnetic transient calculations; impulse corona; lightning impulse; Q-V curve; ultra-high voltage (UHV) bundle conductors; CIRCUIT MODEL; PROPAGATION; TRANSIENTS; DISCHARGE; SIMULATIONS; ATTENUATION; BUNDLES; SURGES; CHARGE;
D O I
10.1109/TPWRD.2013.2278120
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The lightning overvoltage is one of key issues in designing the insulation of transmission line and power apparatus. Usually the influence of the impulse corona is ignored in numerical analysis of electromagnetic transients in power systems due to the lack of experimental data. But the relationship between the overvoltage and the insulation size of 1000-kV ac ultra-high voltage (UHV) power systems enters the nonlinear region, and a small decrease in overvoltage will lead to a high reduction in insulation size and bring huge economical benefits. So fully understanding the corona characteristics of the 1000-kV UHV transmission line is helpful to understand the actual wave process and realize a suitable insulation design of the 1000-kV UHV system. Experiments on the lightning impulse corona characteristic of bundle conductors for 1000-kV transmission lines are carried out in the China UHV ac test base and the impulse corona Q-V curves of different bundle conductors are obtained. The results show that the impulse corona leads the increment of the capacitance of the conductor. Analysis on the Q-V curves shows that the occurrence of the positive impulse corona has a time delay after the lightning impulse voltage exceeds the corona inception voltage and the delay time is a tenth of a microsecond. At the end of this paper, a simulation model for corona based on the empirical formulas of Q-V curves fitted from the test results is proposed, and is applied to the overvoltage analysis of 1000-kV transmission line and substation. The analysis results show the lightning impulse corona has a large influence on the lightning overvoltage of the transmission line and substation.
引用
收藏
页码:2518 / 2525
页数:8
相关论文
共 36 条
  • [21] Probability parameter estimation of outage rate effects for lightning overvoltage analysis on 500 kV EHV double circuit transmission lines using neural networks
    Jaipradidtham, C.
    IPEC: 2005 INTERNATIONAL POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2005, : 803 - 808
  • [22] Transient modeling of transmission lines components with respect to corona phenomenon and grounding system to reduce the transient voltages caused by lightning Impulse
    Mahdiraji, Ebadollah Amouzad
    Ramezani, Nabiollah
    2015 2ND INTERNATIONAL CONFERENCE ON KNOWLEDGE-BASED ENGINEERING AND INNOVATION (KBEI), 2015, : 404 - 410
  • [23] Simulation and experimental analysis of corona loss of 1000 kV and 500 kV AC transmission lines on same tower
    Xie, Xiongjie
    Liu, Qin
    Huo, Feng
    Zhu, Lei
    Liu, Yunpeng
    Zhou, Guoyang
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (03): : 592 - 596
  • [24] Study on Very Fast Transient Overvoltage of Closing No-load China UHV Transmission Demonstration Project Jindongnan-NanyangJingmen 1000 kV Transmission Lines
    Ye, Bo
    Li, Ming
    Bai, Biao
    Qiu, Gefei
    INTERNATIONAL JOURNAL OF GRID AND DISTRIBUTED COMPUTING, 2014, 7 (03): : 273 - 286
  • [25] Flashover pattern analysis for 275 kV double circuit transmission lines during direct lightning strikes
    Ahmed, Nasiru Yahaya
    Illias, Hazlee Azil
    Mokhlis, Hazlie
    Fahmi, Daniar
    Abdullah, Noradlina
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
  • [26] Lightning performance improvement of the Swaziland electricity board transmission system (66kV & 132kV lines) - Results of the pilot project
    Mswane, L. M.
    Gaunt, C. T.
    IEEE Power Engineering Society Inaugural 2005 Conference and Exposition in Africa, 2005, : 364 - 370
  • [27] Statistical Analysis of Radio Interference of 1000 kV UHV AC Double-circuit Transmission Lines in Foul Weather
    Xie, Huichun
    Cui, Xiang
    Wan, Baoquan
    Zhang, Jiangong
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 2 (02): : 47 - 55
  • [28] Potential Distribution Analysis of Y-type Insulators in UHV 1000kV Double Circuit Transmission Lines
    Liao, Jintao
    Peng, Zongren
    Wang, Qingyu
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 576 - 579
  • [29] Flashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower
    Zhang, Yaqi
    Li, Licheng
    Han, Yongxia
    Ruan, Yaoxuan
    Yang, Jie
    Cai, Hansheng
    Liu, Gang
    Zhang, Yi
    Jia, Lei
    Ma, Yutang
    ENERGIES, 2018, 11 (03):
  • [30] Analysis of back-flashover lightning- withstanding level of 500-kv-double-circuit transmission lines
    Wu, Shihong
    Wen, Xishan
    Li, Rui
    Xu, Yang
    Lecture Notes in Electrical Engineering, 2015, 334 : 389 - 397