Analysis of back-flashover lightning- withstanding level of 500-kv-double-circuit transmission lines

被引:0
|
作者
Wu, Shihong [1 ]
Wen, Xishan [1 ]
Li, Rui [1 ]
Xu, Yang [1 ]
机构
[1] College of Electrical Engineering, Wuhan University, Wuhan,430072, China
来源
关键词
Timing circuits;
D O I
10.1007/978-3-319-13707-0_43
中图分类号
学科分类号
摘要
This chapter analyzes the lightning performance of 500-kV-double-circuit transmission lines by the Alternative Transient Performance-Electromagnetic Transient Program (ATP-EMTP). With towers using the multi-wave impedance model and eliminating voltage reflection on the lines by a matching resistor, a simulation method has been established to evaluate the factors that may influence the backflashover voltage such as tower height, tower footing resistance, and conductor phase arrangements. A statistical method is presented to calculate the line trip-out rates due to back-flashover. The results show that the impact of phase arrangements on the back-flashover trip-out rate of a single-circuit line is little, but significant on the double-circuit lines. © Springer International Publishing Switzerland 2015.
引用
收藏
页码:389 / 397
相关论文
共 50 条
  • [1] Techniques for the improvement of the lightning back-flashover performance of double circuit HVDC lines
    Manduley, Nicolas
    Pack, Stephan
    Xemard, Alain
    Toure, Selle
    Raison, Bertrand
    Poullain, Serge
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 200
  • [2] Back-flashover resistance level of ±800 kV/500 kV AC-DC hybrid transmission lines
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu
    610031, China
    不详
    610000, China
    不详
    200122, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 10 (101-106 and 114):
  • [3] Influence of Lightning Back-flashover Intruding Wave on DC Circuit Breaker in ±500 kV MMC-HVDC Transmission System
    Sima W.
    Si Y.
    Yang M.
    Yuan T.
    Xu W.
    Li H.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (08): : 2375 - 2384
  • [4] Lightning back flashover double circuit tripping pattern of 132 kV lines in Malaysia
    Bakar, A. H. A.
    Talib, D. N. A.
    Mokhlis, H.
    Illias, H. A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 45 (01) : 235 - 241
  • [5] Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines
    Jiang, Wenbo
    Tang, Chunlin
    Zhou, Bo
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [6] Flashover pattern analysis for 275 kV double circuit transmission lines during direct lightning strikes
    Ahmed, Nasiru Yahaya
    Illias, Hazlee Azil
    Mokhlis, Hazlie
    Fahmi, Daniar
    Abdullah, Noradlina
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
  • [7] Research on Lightning Performance of Back-flashover of UHV Direct Current Double-circuit Mixed-voltage Transmission Lines on the Same Tower
    Li, Jinliang
    Ren, Huisong
    Xu, Li
    Long, Chenhai
    Yang, Qi
    Xiang, Yun
    2018 10TH INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS (ICCCAS 2018), 2018, : 50 - 54
  • [8] Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines
    Lu, Hailiang
    Wen, Xishan
    Zhang, Chengwei
    Tong, Xuefang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3535 - +
  • [9] Study on lightning performance for ±500 kV DC double circuit transmission lines
    Nie, Dingzhen
    Zhou, Peihong
    Dai, Min
    Wang, Dongmei
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (01): : 148 - 151
  • [10] Flashover characteristics of upper air clearances and lightning withstand level for ±500 kV DC double-circuit transmission line towers
    Ding, Yujian
    Li, Qingfeng
    Liao, Weiming
    Sun, Zhaoying
    Ge, Dong
    Wang, Xi
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (28): : 114 - 119